SWRCB, January 2002 Page of <br />7. UNDER -DISPENSER CONTAINMENT (UDC) TESTING <br />Test Method Developed By: ❑ UDC Manufacturer 0Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum 0 Hydrostatic <br />❑ Other (Specifv) <br />Test Equipment Used: TS -STS <br />M UDC # 1-2 UDC # 3-4 <br />Equipment Resolution: 0.00" <br />UDC # 5-6 <br />UDC # 7-8 <br />UDC Manufacturer: <br />Unknown <br />Unknown <br />Unknown <br />Unknown <br />UDC Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />UDC Depth: <br />40.00" <br />40.00" <br />40.00" <br />40.00" <br />Height from UDC Bottom to Top <br />of Highest Piping Penetration: <br />18.00" <br />18.00" <br />18.00" <br />18.00" <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />24.00" <br />24.00" <br />24.00" <br />24.00" <br />Condition of UDC prior to <br />testing: <br />Clean dry <br />Clean dry <br />Clean dry <br />Clean dry <br />Portion of UDC Tested' <br />Highest penetration <br />Highest penetration <br />Highest penetration <br />Highest penetration <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)?` <br />[]Yes ❑No ONA <br />[]Yes ❑No ONA <br />❑Yes []No ONA <br />[]Yes ❑No ONA <br />Turbine shutdown response time <br />N/A <br />N/A <br />N/A <br />N/A <br />Is system programmed for fail- <br />safe shutdown?* <br />❑Yes ❑No ❑NA <br />❑Yes ❑No ❑NA <br />❑Yes ❑No QNA <br />❑Yes ❑No ❑NA <br />Was fail-safe verified to be <br />operational?* <br />❑Yes ❑No SNA <br />❑Yes ❑No SNA <br />❑Yes ❑No ONA <br />❑Yes ❑No ONA <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />5min <br />5min <br />5min <br />5min <br />Test Start Time: <br />Initial Reading Ri): <br />SEE INCON RESULTS <br />SEE INCON RESULTS <br />SEE INCON RESULTS <br />SEE INCON RESULTS <br />Test End Time: <br />Final Reading (RF): <br />Test Duration: <br />15min <br />15min <br />15min <br />15min <br />Change in Reading (RF -R,): <br />Pass/Fail Threshold or Criteria: <br />0.002" <br />0.002" <br />0.002" <br />0.002" <br />Test Result: <br />0 Pass ❑ Fail <br />0 Pass ❑ Fail <br />El Pass ❑ Fail <br />0 Pass ❑ Fail <br />Was sensor removed for testing? <br />0 Yes ❑No ❑NA <br />EYes ❑No ❑NA <br />[]Yes ❑No ❑NA <br />DYes ❑No [INA <br />Was sensor properly replaced and <br />verified functional after testing? <br />0 Yes ❑No ❑NA <br />DYes ❑No [INA <br />DYes ❑No ❑NA <br />GYes ❑No ❑NA <br />Comments — (include information on repairs made prior to testing. and recommended follotiv-up for failed tests) <br />If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />