Laserfiche WebLink
w <br /> Franklin High School <br /> Installation of a monitoring well near bore hole &1 and former 500 gallon underground storage <br /> tank is approved. <br /> Edison High School <br /> `V <br /> Move one boring more towards the center of the former underground storage tank. Vertical depth <br /> of soil contamination must be determined. This may requi ed obtaining soil samples below <br /> groundwater. <br /> SUSD Corporation Yard <br /> Soil borings at the former underground diesel tank(7) site, former underground gasoline tank <br /> (Tank T1) site, and the slant soil borings at the remote fill reach site (Sample P17), be drilled to a <br /> depth of 35 feet below ground surface (bgs) and 15 to 20 f et bgs, respectively, or until the <br /> borings have extended below the area of soil contaminatiot based on field observation, to define <br /> the vertical extent of hydrocarbon contamination. If contamination extends beyond 35 feet below <br /> grade, drilling must continue until the vertical extent is determined. <br /> The depth of the lateral borings will be determined by the depth of the boring proposed by <br /> samples 598 and 604 for the former diesel tank area and the boring proposed by sample 635 for <br /> the former gasoline area. <br /> The vertical extent must also be determined in the area of P17. Drilling deeper than 15 to 20 feet <br /> below grade may be necessary. One of the slant probes should be changed to a vertical probe. <br /> If you have any questions, please feel free to contact Jeffry Wong at(209)468-0335. <br /> Donna Heran, REHS, Director <br /> Environmental Health Division <br /> Jeffrey Wong , EHS, Trainee Margare agodo, REHS <br /> LOP/Site Mitigation Unit IV Supervisor <br /> JW:ib <br /> c: RWQCB, Central Valley Region-Pat Anderson <br /> c: Noel Lerner, Helmick and Lerner <br /> r <br />