My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2002 - 2003
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1987
>
2300 - Underground Storage Tank Program
>
PR0517565
>
COMPLIANCE INFO 2002 - 2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
2/28/2019 4:14:34 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002 - 2003
RECORD_ID
PR0517565
PE
2361
FACILITY_ID
FA0013503
FACILITY_NAME
SAFEWAY FUEL CENTER #2600
STREET_NUMBER
1987
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
1987 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
282
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
_09/18/2002 09:46 120936F'943 TANKNOLOGY PAGE 10/11 <br /> Monitoring System Cert=ification <br /> Site Address' 1987 W EST 11TH Date of Testing/Gervice: 09/16/2002 <br /> Results of Testing/Servicing <br /> software V9rzion Ir:;ra1'_ef23 <br /> Cam➢lete the following checklist: <br /> x Yes No Is the audible alarm operational? <br /> L,1 Ye? 17 No Is the visual alarm operational? <br /> Q Y^_s M No Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not <br /> Ye= 0 No interfere with their proper operation? <br /> Yes r,c r!1a If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.modem)operational? <br /> For pressurized piping Systems,does the turbine automatically shut down if the piping secondary containment <br /> Yr.: Nc ❑ria monitoring system detects a leak,fails to operate,or Is electrically disconnected?If yes:which sensors initiate positive <br /> shutdown?(check all that apply) Q sump/french Sensors; ® Dispenser Containment Sensors. <br /> Did you confirm positive shutdown due to leaks a13 1 sensor failure/dlsconnectlon? ❑x Yat. No <br /> Y he `�� For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.:no mechanical <br /> © ❑ ❑ overfill prevention valve is installed),is the overfill warning alarm visible and audible at the tank fill points(s)and operating <br /> properly? If so,at what percent of tank capacity does the alarm trigger? 91 t <br /> ElYC!; ❑No Was any monitoring equipment replaced?If yes,identify specific sensors,probes,or other equipment replaced and list the <br /> LJ manufacturer name and model for all replacement parts In Section E,below_ <br /> ❑ Yc� Nc <br /> Was liquid found Inside any secondary containment systems designed as dry systems?(check all that apply) ❑Product; <br /> ❑ Water. It yes,describe causes in Section E,below. <br /> © Yes ❑No Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable. <br /> © Yes 0 tae Is all monitoring equipment operational per manufacturers'specifications? <br /> Lon F below, describe how and when these deficiencns were ox will be correct*d.. <br /> E. Commenta: <br /> North PLLD on Reg is not testable at this time. <br /> Sensors in the Dispenser pans are not place correctly,Brackets not installed yet. I am certifying the sensors trip and shut down <br /> turbine as programed with the exception of the North PLLD on reg at this time. <br /> page 2 o: 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.