My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2009 - 2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1987
>
2300 - Underground Storage Tank Program
>
PR0517565
>
COMPLIANCE INFO 2009 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
2/28/2019 4:35:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009 - 2012
RECORD_ID
PR0517565
PE
2361
FACILITY_ID
FA0013503
FACILITY_NAME
SAFEWAY FUEL CENTER #2600
STREET_NUMBER
1987
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
1987 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
379
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DEC-05-2011 10:32 SERVICE STATION 14089388888 P. 10i10 <br /> 10, FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps ❑ <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ ; <br /> Test Method Developed By: ❑ Sump Manufacturer ®Industry Standard ❑Professional Engineer ° <br /> ❑ Other(Sped) .. <br /> Test Method Used: ❑ Pressure ❑ Vacuum ®Hydrostatic <br /> [3 Other(Sped) t <br /> Test Equipment Used: lncon Sump Tester Equipment Resolution: +/-0.002" <br /> Fill Sump it 87 Fill Sump#91 Fill Sump#Diesel z <br /> Sum Diameter: 42" 42" 42" <br /> SumR Depth: 72" 72" 72" <br /> Height from Tank Top to Top of 18" 18" 24" <br /> Ag hest i2ina Penetration: <br /> Height from Tank Top to Lowest21" 21" 22" '} <br /> Electrical Penetration: <br /> Condition of sump prior to Good Good Good <br /> testing: <br /> Portion of Sum Tested 2"above i in 2"above piping 2" above piping <br /> Sum Material: Fiberglass Fiberglass Fiberglass <br /> Wait time between applying <br /> pressure/vacuum/water and 30 minutes 30 minutes 30 minutes <br /> starting test: - ` <br /> Test Start Time: 8:14 am 9:l 1 am 8:14 am <br /> Initial Reading(Rj): 4.5897 3,6567 1 2,2591 <br /> Test End Time: 8:30 am 9:27 am 8:30 am <br /> Final Reading(RF): 4.5891 3,6563 2,2583 <br /> Test Duration: 16 min. 16 min. 16 min. <br /> Chan a in Reading(RP-R,): -0.0006 -0.0004 -0,0008 ; jj <br /> Pass/Fail Threshold or Criteria: +/_01002" +/-0.002" +/-0.00211 <br /> Test Result: M Pass 2 Fail © Pass 0 Fail 0 Pass 0 Fail ,t <br /> is there a sensor in the sump'? ® Yes ❑No ® 'Yes ❑No ® Yes ❑No <br /> Does the sensor alarm when .:. ' <br /> either product or water is ❑ Yes❑No®NA ❑Yes ❑No ®NA ❑Yes❑No ®NA <br /> detected? <br /> .X <br /> was sensor removed for testing? ®Yes❑No 0 NA ®Yes ❑No NA ® Yes❑No ❑NA <br /> Was sensor properly replaced and ®Yes 0 No[j NA ®Yes ❑No ❑ NA ®Yes [j No El NA <br /> verified functional ager testing? '? ' <br /> Comments— include information on re airs madeprior to testin , and recommended ollow-•u <br /> _ (' f � p g f p for failed tests) , <br /> "Sensor functionality was not confirmed.This procedure is not part of the Secondary Containment testing scope of work". <br /> - ` <br /> ,Iv <br /> T' <br /> i. <br /> ,V^ <br /> TOTAL P.10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.