My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2009 - 2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1987
>
2300 - Underground Storage Tank Program
>
PR0517565
>
COMPLIANCE INFO 2009 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
2/28/2019 4:35:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009 - 2012
RECORD_ID
PR0517565
PE
2361
FACILITY_ID
FA0013503
FACILITY_NAME
SAFEWAY FUEL CENTER #2600
STREET_NUMBER
1987
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
1987 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
379
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DEC-05-2011 10:31 SERVICE STATION 14089388888 P.09i10 <br /> 9. UNDER-DISPENSER CONTAINMENT UDC TESTING <br /> Test Method Developed By: ❑ UDC Manufacturer ® Industry Standard Q Professional Engineer <br /> ❑ Other(Specify) - <br /> Test Method Used: ❑ Pressure ❑ Vacuum ®Hydrostatic <br /> 0 Other(Specify) <br /> Test Equipment Used: Ineon Sump Tester Equipment Resolution: +/-0.002" - a <br /> S� ;� �• X11 <br /> UDC# 17/18 UDC# 19/20 p <br /> UDC Manufacturer: Western fiberglass Western fiberglass <br /> UDC Material <br /> Fiberglass Fiberglass <br /> UDC Depth: 31" <br /> Height from UDC Bottom to Top 531 <br /> of Iiihest Piping Penetration: <br /> Height from UDC Bottom to 12" ;- <br /> Lowest Electrical Penetration: 12 ; <br /> Condition of UDC prior to <br /> tasting= Good Good <br /> Portion of UDC Tested 2"above piping 2"above piping <br /> Does turbine shut down when ti <br /> UDC sensor detects liquid(both ❑Yes ❑No ®NA ❑Yes❑ No ONA „ti4 <br /> product and water)? <br /> Turbine shutdown response time N/A N/A <br /> Is system programmed for fail- <br /> safe shutdown?` ❑Yes❑No ®NA LlYes El No ®NA <br /> Was fail-safe verified to be ` <br /> operational? ❑ Yes C No ®NA ❑Yes C)No I$1NA ; <br /> P. <br /> Wait time between applying <br /> pressure/vacuum/water and 30 minutes 30 minutes <br /> starting test i <br /> Test Start Time: 11:09 am 11:09 am <br /> Initial Reading(Rj): 4.8439 4.3578 <br /> Test End Time: 11:25 am 11:25 am <br /> Final Reading(RF): 4.8444 4,3578 m <br /> Test Duration: 16 min, 16 min. <br /> Change in Reading RF'R +0.0005 None ; <br /> ()� <br /> Pass/Fail Threshold or Criteria: +/-0.002" <br /> Test Result: ® Pass ❑Fail © Pass 0 Rail <br /> Was sensor removed for testing? 10 Yes❑No-ff NA 0 Yes ❑No❑NA <br /> Was sensor properly replaced and M Yes❑No❑NA ®Yes❑No ❑NA 'ry <br /> verified functional after testin . <br /> Comments T (include information on repairs made prior to testing, and reeomrnended follow-up for failed tests) <br /> J <br /> "Sensor functionality was not confirmed.This procedure is not part of the Secondary Containment testing scope of work". <br /> r.r <br /> ' If the entire depth of the UDC is not tested,specify how much was tested. 1f the answer to t of the questions indicated with an <br /> asterisk(*) is"NO" or"NA", the entire UDC must be tested_ (See S INRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.