Laserfiche WebLink
nalN Gy SAN JOAQUIN p <br /> Environmental Health Department <br /> COUNTY Linda Turkatte , REHS , Director <br /> c�6F0RGreatness grows here . Kasey Foley, REHS , Assistant Director <br /> PROGRAM COORDINATORS <br /> Robert McClellon , REHS <br /> Jeff Carruesco, REHS, RDI <br /> Rodney Estrada , REHS <br /> Willy Ng , REHS <br /> Muniappa Naidu , REHS <br /> November 27 , 2018 <br /> Karli Karns <br /> Confidence UST Services , Inc . <br /> 16250 Meacham Rd . <br /> Bakersfield , CA 93314 <br /> Re : Sohal #3 SR0078721 <br /> 2494 E . Fremont St. , Stockton , CA 95205 <br /> The San Joaquin County Environmental Health Department ( EHD) has completed the review of the <br /> application for a permit to : <br /> • Replace the existing STP sumps with new Xerxes sumps <br /> • Replace the existing four UDCs and dispensers <br /> • Install two new UDCs and dispensers <br /> • Replace the vent sump <br /> • Install new penetrations <br /> • Install new piping for the two new dispensers <br /> • Install new sensors for the two new dispensers <br /> on the underground storage tank ( UST) system at the above noted address . The permit has been <br /> approved with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District for any <br /> applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Contact Stacy Rivera at (209) 468-3440 to arrange the following inspection appointments (a 48- <br /> hour notice is required for inspection appointments) . Please be aware that inspections for <br /> emergency work must be scheduled within five days of permit approval . <br /> a . Witness water and/or soil sampling under removed UDCs , vent sump , and any removed piping . <br /> b . Primary piping soap test of all piping and penetrations (product, vapor recovery , and vent) : One- <br /> hour pneumatic pressure test at 110% of operating pressure , or 40 psi , whichever is greater. <br /> c. Secondary piping soap test of all piping and penetrations (product, vapor recovery , and vent) : <br /> One-hour pressure test at the manufacturer' s recommended specification . <br /> d . Secondary piping slope , at 1 /8 inch per foot or greater, to a containment sump with an <br /> audible/visual alarm . <br /> e . Verification of all pipe setbacks and burial depth according to the manufacturer' s installation <br /> instructions . Verification of appropriate backfill . <br /> f. Integrity testing of all STP sumps , UDCs , and vent sumps per the manufacturer' s installation <br /> instructions prior to backfill , and brine type verification and brine addition prior to backfill . <br /> g . Verification of leak monitoring communication for all installed vacuum , pressure , or hydrostatic <br /> (VPH ) components including piping , sumps , under dispenser containment sumps ( UDCs) , and <br /> all chase/crossovers ; communication at end point(s) of each vacuum zone termination must be <br /> verified . All appropriate connections to facilitate communication testing must be present . <br /> h . VPH components installation verification (vent and STP sump rubber gaskets , etc . ) . <br /> 1868 E . Hazelton Avenue I Stockton , California 952051 T 209 468 -3420 1 F 209 464-0138 1 www . sjcehd . com <br />