Laserfiche WebLink
RE ca <br /> CALIFORNIA GEOPHYSICAL GROUP, INC. WATER SAMPLING PROTOCOLS;' MAY 0 3 2004 <br /> ENVIRONMENT HEALTh <br /> Water Sampling Procedures : PERMIT/SERVICES <br /> The equipment used to withdraw water from the well will be a PVC or stainless steel bailer or an electric <br /> pump. All equipment including the bailers , bailing cord , water depth measuring devise, pump electric lines <br /> and hose must be decontaminated prior to entering any well. They will be decontaminated by washing with <br /> non-phosphate detergent and rinsed with tap water. The well will be measured, purged remeasured and a <br /> water sample will be taken immediately after remeasuring. <br /> MEASURING <br /> The depth to groundwater will be measured from the highest point on the top of the casing to the surface of <br /> the water table. This point is marked with black on the casing . The measuring devise used will be an <br /> electric conductivity devise which trips a red light and/or a buzzer when the probe touches water. A <br /> minimum of three measurements will be made at each well , the final reading will be noted after 2 or more <br /> readings do not vary by more than 0. 01 feet The total depth of the well will also be measured . This <br /> information along with water parameters mentioned later will be entered onto the sampling sheet. The <br /> casing volume will be calculated according to the formula supplied on the sampling sheet. <br /> FLOATING FREE PRODUCT <br /> The presence of floating free product will be checked by recording the depth of the water and marking that <br /> level on the probe wire . The probe and wire will be withdrawn from the well and dried. Liquid paste of chalk <br /> will be placed on the probe and up the side of the wire for 2 feet(could be higher depending on the depth of <br /> the plume). The probe is then carefully lowered into the well so that the probe just touches the water table, <br /> care will be taken not to lower the probe below the water table. Once the probe has buzzed at the water <br /> table it is withdrawn quickly from the well and the liquid level above the water level point on the probe is <br /> recorded. This differential bet,veen the liquid level and the probe water sensing point is the floating product <br /> thickness and will be recorded on the sampling sheet. <br /> Water samples will be obtained as follows: <br /> A) First, one casing volume of water will be withdrawn from the well; <br /> B) The parameters of pH , conductivity, temperature and oxygen will be measured. The color, odor and <br /> presence of sheen of the purged water will be noted; <br /> C) A 2"d and 3`d casing volume of water will be withdrawn and the parameters remeasured , if the results <br /> from the third measuring vary by more than 1001: for the conductivity or temperature or 0. 1 on the pH <br /> reading then step C is repeated until the readings are within the limits . <br /> D) The well will be allowed to recover to 80% of its original volume or 2 hours have passed (remeasured) <br /> then a sample will be withdrawn and placed in the appropriate sample bottle supplied by a California <br /> Certified Analytical Laboratory. The Labs supply the sample vials with the proper amount of Hydrochloric <br /> Acid in each bottle, so no further acid or any other chemical should be added to the water. The bottles will <br /> be placed on ice in a cooler and kept on ice until delivered to the lab or turned over to their courier within 48 <br /> hours of the sampling time . <br /> it <br />