Laserfiche WebLink
M <br /> Purged water will be placed in a sealed drum and left at the site. The drums will be labeled for the source of <br /> the water. After the chemical analyses are completed the contamination in each drum will be assessed. If <br /> the chemical analyses of the water in a drum shows the water to be free of contamination then this water <br /> will be disposed of as clean water. Contaminated water will be removed from the site by a licensed waste <br /> hauler. <br /> Water samples will be taken from the water at or near the surface of the water table, unless otherwise <br /> indicated. The containers will be filled so that zero headspace is present in the sealed vial before placing in <br /> the cooler. A Chain of Custody will be filled out by the sampler. The one liter brown bottles for TPH-diesel <br /> must have a small 40 to 60 ml of headspace, if not the bottle will break during transport. <br /> All laboratory results , well measurements and the Chain of Custody must be sent to our office for evaluation <br /> and the preparation of a report. <br />