Laserfiche WebLink
S A N X10 A Q U I NEnvironmental Health Department <br /> COUNTY AMENDED <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> ARCO STATION#826951` 130 S 1MLSON WAY, STOCKTON January 19, 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I.CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 103 HSC 25292.2, 25299.30 Current financial responsibility documents not submitted. <br /> Current financial responsibility documents have not been submitted to the California Environmental Reporting <br /> System(CERS). Current financial responsibility documents are required to be submitted annually. During the <br /> inspection, facility personnel uploaded a current financial responsibility document onto CERS. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> An accurate UST Monitoring Site Plan was not submitted. The site map is missing the piping layout for the vent and <br /> vent sump sensor.A site plan must be submitted identifying the locations where monitoring will be performed. <br /> Immediately log into the California Environmental Reporting System (CERS)at http://cers.calepa.ca.gov/and upload <br /> a copy of the UST Monitoring Site Plan. During the inspection,facility personnel uploaded a current site map. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> 110 CCR 2637(e) Failed to submit secondary containment test report within 30 days. <br /> Secondary containment testing was scheduled to be performed on 5/24/17. A test report has not been submitted to <br /> the EHD or the California Environmental Reporting System (CERS). A copy of the test report must be submitted <br /> within 30 days of the test. Immediately submit a copy of the test report to the EHD or schedule this test and provide <br /> 48 hours notification to the EHD. A copy of the current secondary containment test report was provided to EHD by <br /> the facility during inspection. <br /> This was corrected on site. <br /> This is a minor violation. <br /> 201 CCR 2712(b) Failure to maintain monitoring, maintenance, and follow up action records. <br /> The facility did not document all alarms and the appropriate follow up. There was an L8 dispenser 3/4 sensor out <br /> alarm on 5/24/17 that was not documented by the facility.These records shall be maintained on site for at least <br /> three years. Monitoring records include: (1)date and time of all monitoring or sampling; (2)monitoring equipment <br /> calibration and maintenance records; (3)results of any visual observations; (4)results of sample analysis performed <br /> a lab or in the field; (5)logs of all readings of gauges or other monitoring equipment, ground water elevations, or <br /> other test results; (6)results of inventory readings and reconciliations. Immediately locate and maintain all <br /> maintenance and monitoring records for the last three years on site and submit copies to the EHD. <br /> The facility personnel provided a statement during inspection. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> FA0003601 PR0231861 SCO01 01/19/2018 <br /> EHD 23-01 Rev.10/31/2017 Page 4 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />