My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PAVILION
>
2850
>
1600 - Food Program
>
PR0535710
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/18/2024 2:19:47 PM
Creation date
3/21/2019 1:14:40 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0535710
PE
1619
FACILITY_ID
FA0020585
FACILITY_NAME
WinCo Foods #103
STREET_NUMBER
2850
STREET_NAME
PAVILION
STREET_TYPE
Pkwy
City
Tracy
Zip
95304
CURRENT_STATUS
01
SITE_LOCATION
2850 Pavilion Pkwy
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\lsauers1
标签
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
86
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REVISIONS <br /> GENERAL NOTES <br /> No. Description Date <br /> 1 CERTAIN EQUIPMENT REQUIREMENTS NOTED ON THESE DRAWINGS WERE DERIVED <br /> FROM OWNER-FURNISHED COORDINATION DRAWINGS. CONTRACTOR TO VERIFY <br /> ACTUAL OWNER-FURNISHED EQUIPMENT CONNECTION REQUIREMENTS AND SCOPE <br /> OF WORK. CONTRACTOR TO PROVIDE INSTALLATION OF ALL OWNER SUPPLIED <br /> PLUMBING FIXTURES. <br /> 2 CONTRACTOR TO FIELD VERIFY LOCATION OF EXISTING SANITARY AND DOMESTIC <br /> 0 9 LINES. VERIFY AVAILABLE INVERT DEPTHS PRIOR TO BEGINNING WORK. <br /> (E)1"CW 3 THE INTENTION OF THE CONTRACT DOCUMENTS IS TO INCLUDE ALL LABOR AND <br /> ( HW... I MATERIALS,AND EQUIPMENT NECESSARY,OR REASONABLY INFERABLE AS BEING, <br /> 314 HWC�` FOR FURNISHING,INSTALLTION AND TESTING,COMPLETE AND READY FOR SAFE Axcx.PROJECT NO. <br /> { l._. . (E) <br /> � <br /> (TYP.) /1` � _:.I', i I OPERATION OF THE SYSTMS DESCRIBED HEREIN. 1902 <br /> 4 <br /> 1 4 COORDINATE LOCATION OF VENTS'THROUGH ROOF TO MAINTAIN I O'-0" Mcg <br /> CLEARANCE FROM OUTSIDE AIR INTAKES. EACH VENT EXTENSION THROUGH A CHECKED <br /> ' ROOF SHALL BE AT LEAST 3"IN DIAMETER&TERMINATE NOT LESS THAN 12" RwD <br /> 2k•a ABOVE THE ROOF OR AS RE' - UIRED BY THE ADMINISTRATIVE AUTHORI'T'Y. <br /> � I I ' ,'r' � Q St)BMtTTALDATES <br /> - III <br /> 5 ALL PENETRATIONS MADE THROUGH RATED ASSEMBLES TO ACCOMODATE WORK <br /> OF THIS SECTION,MUST BE SEALED TO MAINTAIN THE RATING OF SUCH ASSEMBLY <br /> J, ;�,' - EALING METHOD. OTB DATE <br /> f ! BY AUL RECOGNIZED S <br /> 12/12138 <br /> 6 ALL SEWERS BELOW GRADE INSIDE BUILDING OR ABOVE GRADE SHALL BE SLOPED <br /> - — J -- - - — - — - F <br /> CF - - — , ' - - — — - T - u — F PER THE REQUIREMENTS OF THE PLUMBING CODE AND AMENDMENTS ADOPTED BY <br /> i --- - -� <br /> - •, THE LOCAL,AHJ <br /> �, 2 <br /> (E)2"VTR--a---3C�7 /+ ` SYSTEM -' 7 FLOOR SINKS BELOW REFRIGERATED CASE TO BE HALF-EXPOSED. COORDINATE <br /> de (TYP.) ;,-� 5 (TYP.) LOCATION WITH REFRIGERATION CONTRACTOR.RE:RI. <br /> - -. <br /> � ,,-'•-'"-- ����� �•'A' L. _._.___ -_ -____ � � '� •' •' I 8 INDIVIDUAL VERTICAL VENT SIZES ARE NOT SHOWN ON PLAN FOR FIXTURES <br /> 4 ` �. `, SPECIFIED IN SCHEDULE. REFER TO PLUMBING FIXTURE SCHEDULE FOR SIZES. �, x o <br /> ' may' 9 PLUMBING CONTRACTOR SHALL HIRE A SURVEYOR TO PLOT POINTS FOR ALL NEW ° o C a, <br /> o� F- <br /> FLOOR SINKS TO ACCURATELY LOCATE FLOOR SINKS AND TO CONFIRM II1VIS a o. Z n <br /> 1 1 I I HEIGHTS OF THE TOP OF ALL SURFACES. LE FOR CW HW SS AND VENT SIZES TO o o w w z . 3 <br /> ICxFdu 2 <br /> 10 REFER TO THE PLUMBING FIXTURESCSCHEDULE x o ut <br /> INDIVIDUAL FIXTURES. o �, U <br /> C3 Ij <br /> 11 ROUTE PIPING OVER MAIN SALES AND OTHER AREAS WITHIN TRUSS SPACE n z �a z o 6 <br /> REMOVE EXISTING._......-- Q w o <br /> ' 1 I 1 WHENEVER POSSIBLE. a <br /> PIPING IN CASES; I m t o <br /> 12 REMOVE ALL EXPOSED UNUSED WASTE AND VENT PIPING. w <br /> 0 13 CONTRACTOR SHALL SAWCUT EXISTING CONCRETE SLAB FLOOR AS REQUIRED FOR N <br /> NZ <br /> INSTALLATION OF NEW WASTE AND VENT PIPING. <br /> (TYP.) <br /> Ii I I I I <br /> 14 THE POINT OF DISCONNECTION REMAINING IN A PIPING SYSTEM AFTER PIPING HAS V <br /> 1 I I f BEEN REMOVED SHALL BE PERMANENTLY CAPPED AIR AND WATER TIGHT. O m <br /> I <br /> y I I I I I 15 COORDINATE PIPING WITH ALL OTHER TRADES PRIOR TO INSTALLATION TO AVOID <br /> CONFLICTS. v <br /> I i <br /> tomo 16 CONTRACTOR SHALL RETAIN AND PROTECT ALL EXISTING FIXTURES,EQUIPMENT, <br /> 4 �ca <br /> TRAP PRIMERS,FLOOR SINKS,FLOOR DRAINS,TRENCH DRAINS,AND ALL <br /> ASSOCIATED PIPING NOT SPECIFICALLY SHOWN TO BE REMOVED OR RELOCATED y <br /> I ! <br /> ON THIS SET OF PLANS.o� <br /> �/ z <br /> t — - - - - - - - - - - - - - - --C() <br /> KEYED NOTES wm a <br /> t I I cw <br /> 1 I(E)2"VTR 1 RETAIN AND PROTECT. SEE GENERAL NOTE 16,THIS SHEET. oW. <br /> 2 RETAIN AND PROTECT EXISTING RO WATER PIPING AND SHUT-OFF VALVES ABOVE 0 dL o O <br /> N <br /> CASES. .,a <br /> I I i I 1 I i I 1 <br /> 3 CAP EXISTING PIPING ABOVE CASES AND REMOVE EXIS'T`ING PIPING DOWNSTREAM. � <br /> I <br /> 4 REMOVE EXISTING FLOOR SINK IN ITS ENTIRETY.TEMPORARILY CAP EXISTING �.. <br /> WASTE PIPING BELOW FLOOR FOR RE-CONNECTION. RE:P1. <br /> 5 EXISTING REFRIGERATED CASE TO BE TEMPORARILY RELOCATED. EXTEND <br /> � I <br /> I 1 I i CONDENSATE PIPING FROM TEMPORARY CASE LOCATION TO EXISTING FLOOR SINK <br /> i ' I AS REQUIRED AND INDIRECT WITH AIRGAP. <br /> I QPpFFSSIpN <br /> {� I <br /> CO N0. 31885 z <br /> Ir <br /> (TYP.) —j j I I FCNAPIIG�� <br /> ------ _____________ OFCA <br /> � I - � �----....�....»_�_»_� - -�� 12/12/18 <br /> 4 <br /> 5 <br /> ,- _--__--------------- ---------------_.--._--------- <br /> ' i I <br /> E--.I 1�-1 <br /> 4 <br /> ' 1 (E)2"VTR <br /> I i <br /> OD <br /> I I U <br /> , <br /> - <br /> t 1 <br /> � P4/ 14 0 <br /> �14 <br /> � o � o <br /> ---------------------- <br /> v <br /> CC. -------- <br /> 2)--- - � - r- - --,- - - - - -_ _ _ _ - - - - - - C.2 C.2 - - - <br /> ' <br /> 5 5 <br /> Q U U <br /> � I t � F' I f <br /> � I 1 {TYP.} �� <br /> o <br /> I --opo L.. ...� <br /> i <br /> { L _ _ J <br /> , , 0.4 PLO <br /> (E)SLOPE--> <br /> _—_-(E)4„SS_ _—_ -- ------_—_� <br /> (E)4„ECO&B - <br /> - - - - - - - - - - - - <br /> ,T <br /> I <br /> I <br /> THE PLUMBING CONTRACTOR SHALL <br /> PARTIAL WASTE AND VENT PARTIAL DOMESTIC WATER ° PROVIDE ALL NECESSARY PIPING FOR 1 <br /> PLUMBING DEMOLITION PLAN - PRODUCE PLUMBING DEMOLITION PLAN - PRODUCE ALL CASES TEMPORARILY <br /> 3132” = 1'4" 3132„ = 1'-0" <br /> RELOCATED AND USED DURING TIME <br /> OF CONSTRUCTION. <br /> SHEET TITI-,E <br /> PARTIAL PLUMBING <br /> DEMOLITION PLANS <br /> PRODUCE <br /> SHEET <br /> Ptd . I <br />
The URL can be used to link to this page
Your browser does not support the video tag.