My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PAVILION
>
2850
>
1600 - Food Program
>
PR0535710
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/18/2024 2:19:47 PM
Creation date
3/21/2019 1:14:40 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0535710
PE
1619
FACILITY_ID
FA0020585
FACILITY_NAME
WinCo Foods #103
STREET_NUMBER
2850
STREET_NAME
PAVILION
STREET_TYPE
Pkwy
City
Tracy
Zip
95304
CURRENT_STATUS
01
SITE_LOCATION
2850 Pavilion Pkwy
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\lsauers1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
86
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REVISIONS <br /> GENERAL NOTES No. Description Date <br /> 1 CERTAIN EQUIPMENT REQUIREMENTS NOTED ON THESE DRAWINGS WERE DERIVED <br /> FROM OWNER-FURNISHED COORDINATION DRAWINGS. CONTRACTOR TO VERIFY <br /> ACTUAL OWNER-FURNISHED EQUIPMENT CONNECTION REQUIREMENTS AND SCOPE <br /> OF WORK. CONTRACTOR TO PROVIDE INSTALLATION OF ALL OWNER SUPPLIED <br /> PLUMBING FIXTURES, <br /> 2 CONTRACTOR TO FIELD VERIFY LOCATION OF EXISTING SANITARY AND DOMESTIC <br /> LINES. VERIFY AVAILABLE INVERT DEPTHS PRIOR TO BEGINNING WORK <br /> 3 THE INTENTION OF THE CON'T'RACT DOCUMENTS IS TO INCLUDE ALL LABOR AND _ <br /> 2 MATERIALS,AND EQUIPMENT NECESSARY,OR REASONABLY INFERABLE AS BEING, ARCH,PROJECT 110, <br /> FOR FURNISHING,INSTALLTION AND TESTING,COMPLETE AND READY FOR SAFE 1802 <br /> OPERATION OF THE SYSTMS DESCRIBED HEREIN. DRAWN <br /> 4 COORDINATE LOCATION OF VENTS THROUGH ROOF TO MAINTAIN 10'-0" 1Mc <br /> CHECKED <br /> CLEARANCE FROM OUTSIDE AIR INTAKES. EACH VENT EXTENSION THROUGH A RWM <br /> ROOF SHALL BE AT LEAST 3" IN DIAMETER&TERMINATE NOT LESS THAN 1.2" SUBMUTAL DATES W <br /> ABOVE THE ROOF OR AS REQUIRED BY THE ADMINISTRATIVE AUTHORITY. 12/12!18 <br /> �------(E)4"SS-— ---�---------(E)4"SS----� <br /> 5 ALL PENETRATIONS MADE THROUGH RATED ASSEMBLIES TO ACCOMODATE WORK <br /> OF THIS SECTION,MUST BE SEALED TO MAINTAIN THE RATING OF SUCH ASSEMBLY OTB BATE <br /> 1 (E)2"CW BY A U.L.RECOGNIZED SEALING METHOD. 12J12118 <br /> - (E)1"HW i 6 ALL.SEWERS BELOW GRADE INSIDE BUILDING OR ABOVE GRADE SHALL BE SLOPED <br /> (TYP-) 71, <br /> PER THE REQUIREMENTS OF THE PLUMBING CODE AND AMENDMENTS ADOPTED BY <br /> THE LOCAL AHJ. <br /> tr 7 FLOOR SINKS BELOW REFRIGERATED CASE TO BE HALF-EXPOSED. COORDINATE o �' <br /> LOCATION WITH REFRIGERATION CONTRACTOR.RE:R1. °a x °a t� C! c <br /> 8 INDIVIDUAL VERTICAL VENT SIZES ARE NOT SHOWN ON PLAN FOR FIXTURES <br /> O a <br /> I <br /> SPECIFIED IN SCHEDULE. REFER TO PLUMBING FIXTURE SCHEDULE FOR SIZES. w � <br /> 1 i 9 PLUMBING CONTRACTOR SHALL HIRE A SURVEYOR TO PLOT POINTS FOR ALL NEW o ® w <br /> r5x ��� Z ❑ <br /> i I I-Isf�� FLOOR SINKS TO ACCURATELY LOCATE FLOOR SINKS AND TO CONFIRM FINISH ° °° a-o 0 <br /> HEIGHTS OF THE TOP OF ALL SURFACES. Z 3 <br /> 10 REFER TO THE PLUMBING FIXTURE SCHEDULE FOR CW,HW,SS AND VENT SIZES TO <br /> INDIVIDUAL FIXTURES. z ° o 3 <br /> ROUTE PIPING OVER MAIN SALES AND OTHER AREAS WITHIN TRUSS SPACE ° <br /> WHENEVER POSSIBLE. ° 3 <br /> —I I I I II I ISI <br /> t L J I I I 12 REMOVE ALL EXPOSED UNUSED WASTE AND VENT PIPING. <br /> 13 CONTRACTOR SHALL SAWCUT EXISTING CONCRETE SLAB FLOOR AS REQUIRED FOR <br /> w r I INSTALLATION OF NEW WASTE AND VENT PIPING. 0 <br /> I L J 1 I 14 THE POINT OF DISCONNECTION REMAINING IN A PIPING SYSTEM AFTER PIPING HAS p m <br /> 116 = = = I j' BEEN REMOVED SHALL BE PERMANENTLY CAPPED AIR AND WATER TIGHT. * y <br /> f 15 COORDINATE PIPING WITH ALL OTHER TRADES PRIOR TO INSTALLATION TO AVOID Q <br /> 2 2f <br /> � I CONFLICTS. �•.. U � <br /> 16 CONTRACTOR SHALL RETAIN AND PROTECT ALL EXISTING FIXTURES,EQUIPMENT, <br /> 'TRAP PRIMERS,FLOOR SINKS,FLOOR DRAINS,TRENCH DRAINS,AND ALL W <br /> ASSOCIATED PIPING NOT SPECIFICALLY SHOWN TO BE REMOVED OR RELOCATED �y <br /> I I y i ON THIS SET OF PLANS. li Z <br /> I I t <br /> N d KEYED NOTES = w <br /> C <br /> 1. RETAIN AND PROTECT. SEE GENERAL NOTE 16,THIS SHEET. I"' w <br /> t I J(E)3 VTR <br /> r'� a <br /> 00 <br /> 2. REMOVE EXISTING FIXTURE. RETAIN AND PROTECT EXISTING WASTE,VENT, <br /> I COLD AND OR HOT WATER IN WALL FOR CONNECTION TO NEW FIXTURE. RE:P2. C <br /> war <br /> N <br /> 2 <br /> H. <br /> -- -L�k- h �.` -} _ =' NO. 31885 � <br /> `' 7 �A-......��\ 7�-�7 ��� �.� <br /> A _ m <br /> A A <br /> ( 1 )(E)4"WW 9TFOACA%-% Q_ <br /> 12/12/18 <br /> � 0 <br /> PARTIAL PLUMBING DEMOLITION PLAN - RESTROOM <br /> w o <br /> 114" 1'-0" <br /> 40O <br /> U � � C) O <br /> o � u © U <br /> 1 <br /> SHEET TITLE <br /> PARTIAL PLUMBING <br /> DEMOLITION PLAN <br /> RESTROOM <br /> SHEET <br /> PO * 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.