My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PAVILION
>
2850
>
1600 - Food Program
>
PR0535710
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/18/2024 2:19:47 PM
Creation date
3/21/2019 1:14:40 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0535710
PE
1619
FACILITY_ID
FA0020585
FACILITY_NAME
WinCo Foods #103
STREET_NUMBER
2850
STREET_NAME
PAVILION
STREET_TYPE
Pkwy
City
Tracy
Zip
95304
CURRENT_STATUS
01
SITE_LOCATION
2850 Pavilion Pkwy
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\lsauers1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
86
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL NOTES REVISIONS <br /> �"E` No. Description Date <br /> 1 CERTAIN EQUIPMENT REQUIREMENTS NOTED ON THESE DRAWINGS WERE DERIVED <br /> FROM OWNER-FURNISHED COORDINATION DRAWINGS. CONTRACTOR TO VERIFY <br /> ACTUAL OWNER FURNISHED EQUIPMENT CONNECTION REQUIREMENTS AND SCOPE <br /> OF WORK. CONTRACTOR TO PROVIDE INSTALLATION OF ALL OWNER SUPPLIED <br /> PLUMBING FIXTURES. <br /> 2 CONTRACTOR TO FIELD VERIFY LOCATION OF EXISTING SANITARY AND DOMESTIC <br /> 10 9 10 9 LINES. VERIFY AVAILABLE INVERT DEPTHS PRIOR TO BEGINNING WORK. <br /> (E)1"CW 3 THE INTENTION OF THE CONTRACT DOCUMENTS IS TO INCLUDE ALL LABOR AND <br /> MATERIALS,AND EQUIPMENT NECESSARY,OR REASONABLY INFERABLE AS BEING, <br /> i I (E)1 HW .. 7 _ FOR FURNISHING,INSTALLTION AND TESTING,COMPLETE AND READY FOR SAFE <br /> (E)314"HWC� .PROJECT NO, <br /> I _._.__ — OPERATION OF THE SYSTMS DESCRIBED HEREIN. ARCH. <br /> I I � TYP. � -_ _. _. � I ; <br /> i ( ) 4 COORDINATE LOCATION OF VENTS THROUGH ROOF TO MAINTAIN 10'70" DRAWN <br /> CLEARANCE FROM OUTSIDE AIR INTAKES. EACH VENT EXTENSION THROUGH A CHECKED <br /> 1 I i _._ _ ROOF SHALL BE AT LEAST 3"IN DIAMETER&TERMINATE NOT LESS THAN 12" <br /> _....__ PWD <br /> -- I __.__.....- .--_. _._-. I I I I ' i ABOVE THE ROOF OR AS REQUIRED BY THE ADMINISTRATIVE AUTHORITY, SUBM7TAL DATES <br /> 5 ALL PENETRATIONS MADE THROUGH RATED ASSEMBLIES TO ACCOMODATE WORK a21�2r�s <br /> - <br /> W I FS I / i OF THIS SECTION,MUST BE SEALED TO MAINTAIN THE RATING OF SUCH ASSEMBLY <br /> 4 1 - - BY A U.L.RECOGNIZED SEALING METHOD. OTB DATE <br /> r <br /> I 1 / 2 it I 6 ALL SEWERS BELOW GRADE INSIDE BUILDING OR ABOVE GRADE SHALL BE SLOPED az�sz�ts <br /> F _ _ _ _ _ _ PER THE REQUIREMENTS OF THE PLUMBING CODE AND AMENDMENTS ADOPTED BY <br /> — - — - — - `' - - - --1 THE LOCAL AHI. <br /> (E)2"VTR � i � i 1 i I 7 FLOOR SINKS BELOW REFRIGERATED CASE TO BEHALF-EXPOSED. COORDINATE <br /> LOCATION WITH REFRIGERATION CONTRACTOR.RE:R1. r <br /> 1 <br /> SYSTEM <br /> , 3 I ARE NOT SHOWN ON PLAN FOR FIXTURES o w o <br /> � I 8 INDIVIDUAL VERTICAL VENT SIZES �o <br /> FS 2 - - SSTEM <br /> 1 'I' <br /> I � } SPECIFIED IN SCHEDULE. REFER TO PLUMBING FIXTURE SCHEDULE FOR SIZES. ¢���¢°��o�`� Ixa <br /> 9 PLUMBING CONTRACTOR SHALL HIRE A SURVEYOR TO PLOT POINTS FOR ALL NEW w <br /> 6 HEIGHTS OF THE TOP OF ALL SURFACES.FLOOR SINKS AND TO CONFIRM FINISH <br /> o b <br /> zaq <br /> i <br /> 5m�s�-$0 llo�,o0 ° <br /> CD 10 REFER TO THE PLUMBING FIXTURE SCHEDULE FOR CW,HW,SS AND VENT SIZES TO o' o <br /> wz <br /> a�� U <br /> (E)4"FCO 3 INDIVIDUAL FIXTURES. <br /> (TYP) <br /> I . <br /> S I 11 ROUTE PIPING OVER MAIN SALES AND OTHER AREAS WITHIN TRUSS SPACE <br /> F <br /> WHENEVER POSSIBLE. w w o <br /> 1 _ M <br /> ° a3 <br /> 2 <br /> f I 12 REMOVE ALL EXPOSED UNUSED WASTE AND VENT PIPING. <br /> 13 CONTRACTOR SHALL SAWCUT EXISTING CONCRETE SLAB FLOOR AS REQUIRED FOR <br /> INSTALLATION OF NEW WASTE AND VENT PIPING. <br /> UO I -- -- - HAS rr� <br /> DISCONNECTION <br /> REMAINING IN A PIPING SYSTEM AFTER PIPING V <br /> (TYP.) I I� �.._..__.J 4 � <br /> �.-__-.._ ._�-. _ _ i--_ 14 THE POINT OF S <br /> BEEN REMOVED SHALL BE PERMANENTLY CAPPED AIR AND WATER TIGHT. �1 p" <br /> 15 COORDINATE PIPING WITH ALL OTHER TRADES PRIOR TO INSTALLATION TO AVOID * ¢ <br /> �M <br /> CONFLICTS. � � C'i � <br /> W I I 16 CONTRACTOR SHALL RETAIN AND PROTECT ALL EXISTING FIXTURES,EQUIPMENT, Q N <br /> (TYP.) (TYP.) -^ = - _1 —_ - TRAP PRIMERS,FLOOR SINKS,FLOOR DRAINS,TRENCH DRAINS,AND ALL { <br /> - I ___J ASSOCIATED PIPING NOT SPECIFICALLY SHOWN TO BE REMOVED OR RELOCATED cn <br /> PS ON THIS SET OF PLANS. w <br /> I __ _ _ <br /> KEYED NOTES <br /> E _ _ f- _ � _ - - _ _ - _ - - - E i <br /> i � 1 RETAIN AND PROTECT. SEE GENERAL NOTE 16,THIS SHEET. <br /> } I I --- 1 2 CONNECT TO EXISTING 2"WASTE BELOW FLOOR AND EXTEND NEW 2"WASTE'I'O <br /> (E)2"VTR I _ NEW FLOOR SINK. PATCH FLOOR. RE:ARCH. O $O <br /> 3 CONNECT NEW 112" CW TO PRODUCE CASE QUICK DISCONNECT SPRAY HOSES. C 8 a <br /> I I I COORDINATE WI REFRIGERATION CONTRACTOR. C <br /> 4 CONNECT TO EXISTING CW AND DROP NEW 112"CW DOWN WALL&RUN INTO BACK <br /> - .......1 __ � _ _� OF PRODUCE CASE FOR CONNECTION TO QUICK DISCONNECT SYSTEM. PROVIDE <br /> . <br /> I .. ..........�..._L.._... .._ - = <br /> 1/2"HAND <br /> N WITH SIGN�OCATIONS ON WALL, FRONT OF CASE. COORDINATE <br /> DROP <br /> 5 CONNECT TO EXISTING SHUT-OFF VALVES ABOVE CASES FOR CONNECTION TO <br /> MISTING SYSTEM. FINAL CONNECTION TO MISTING SYSTEM TO BE MADE BYSM;�Nq� <br /> 2 F 7' I MISTING SYSTEM SUPPLIER. ,- P� 4!� Fy <br /> i 6 CONNECT TO EXISTING RO PIPING AND INSTALL NEW 112"RO TO SHUT-OFF VALVE o �= <br /> FOR _ <br /> ." NO. 37885 z <br /> I I I 3 MISco In <br /> OVE TING SYSTEM TO BE MADEOBY MISTING SYSTEN TO MISTING M SUPPLIERCONNECTION TO <br /> I � 7 RUN NEW CW IN PRODUCE CASE.RE:P5-2 <br /> I I �HAN�G <br /> (TYP.) �TFp� p}IF���\P <br /> � - - - - - - -FEE <br /> D 12/12/18 <br /> - _ <br /> iiL_L <br /> II — <br /> FS,! } I <br /> 2 <br /> jI� 11 <br /> ll _ � <br /> (E)2"VTR — <br /> (E)2"VBF T - <br /> TYP. I FS - r j - y W -. i .sS v_ a [^� <br /> ` 1 -- - - <br /> F O <br /> TI i Q �-4 U U <br /> I (TYP.) <br /> BOO <br /> �I i <br /> 2"VBF <br /> (E)SLOPE---> <br /> ;I <br /> -------(E)4"SS--- ---- ---_ _ _ -----� ' <br /> li E)4..FCO(F)_ - <br /> I <br /> ........... <br /> 1 <br /> THE PLUMBING CONTRACTOR SHALL <br /> PARTIAL WASTE AND VENTDOMESTIC WATER PLUMBING �o� I PROVIDE ALL NECESSARY PIPING FOR 1 <br /> PLUMBING PLAN PRODUCE PLAN - PRODUCE ALL CASES TEMPORARILY <br /> 3132" = 1'4" 3132" = 1'-0" <br /> RELOCATED AND USED DURING TIME <br /> OF CONSTRUCTION. <br /> SHEET TITLE <br /> PARTIAL PLUMBING <br /> CD <br /> PLUMBING PLANS <br /> PRODUCE <br /> SHEET <br /> P I <br />
The URL can be used to link to this page
Your browser does not support the video tag.