My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2001 - 2016
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
6100
>
2300 - Underground Storage Tank Program
>
PR0231630
>
COMPLIANCE INFO_2001 - 2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:12 PM
Creation date
3/21/2019 1:31:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001 - 2016
RECORD_ID
PR0231630
PE
2361
FACILITY_ID
FA0003630
FACILITY_NAME
ARCO STATION #595*
STREET_NUMBER
6100
Direction
N
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95212
APN
08704034
CURRENT_STATUS
02
SITE_LOCATION
6100 N HWY 99
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
249
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 6—of <br /> 8. _.LL RISER CONTAINMENT SUMP TING <br /> Facility is Not Equipped With Fill Riser Containment Sums ❑ <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed By: ❑Sump Manufacturer ® Industry Standard ❑Professional Engineer <br /> ❑Other(Specify) <br /> Test Method Used: ❑Pressure ❑ Vacuum ® Hydrostatic <br /> [I Other(Specify) <br /> Test Equipment Used: Wayne Perry Inc. See Attached Results Equipment Resolution: .0007" <br /> Sump# �� Sump# 7-� Sump# �' Sump# <br /> Sump Diameter: Z " � <br /> Sump Depth: <br /> Sump Material: <br /> Height from Tank Top to Top of l� „� <br /> Highest Piping Penetration: / �-I �7 <br /> Height from Tank Top to Lowest ! , <br /> Electrical Penetration: <br /> Condition of sump prior to testing: Cu <br /> Portion of Sump Tested' 2"ABOVE HIGHEST 2"ABOVE HIGHEST 2"ABOVE HIGHEST 2"ABOVE HIGHEST <br /> PENETRATION PENETRATION PENETRATION PENETRATION <br /> Wait time between applying water 15 Minutes 15 Minutes 15 Minutes 15 Minutes <br /> and starting test: <br /> Test Start Time: / ,3G <br /> Initial Reading(Ri): 4rO� rc' <br /> Test End Time: /Z y/ //,3 jZ, <br /> Final Reading(RF): o/ 6s�f"Z7 <br /> Test Duration: 15 Min 15 Min 15 Min 15 Mn 15 Min 15 Min 15 Min 15 Min <br /> Change in Reading(RF-Ro: P069( 6 <br /> Pass/Fail Threshold or Criteria: -0.00 -0.0020 -0-00 -0.0020 -0.002 -0.0020 -0.0020 -0.0020 <br /> IR 2�k <br /> Is there a sensor in the sump? ❑Yes ❑No ❑NA es ❑No ❑NA B`V�s ❑No ❑NA ❑Yes ❑No ❑NA <br /> Does sensor alarm when either ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA O Yes [I No ❑NA <br /> product or water is detected? <br /> Was sensor removed for Testing? ❑Yes O No O NA es ❑No ❑NA es ❑No ❑NA O Yes ❑No O NA <br /> Was sensor properly replaced and 34–e-s ❑No ❑NA 04es ❑No ❑NA ffl�s ❑No p NA ❑Yes O No ❑NA <br /> verified functional after testing? <br /> Comments–(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.