My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2000 - 2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
3212
>
2300 - Underground Storage Tank Program
>
PR0231035
>
COMPLIANCE INFO 2000 - 2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2024 2:39:12 PM
Creation date
3/26/2019 2:45:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2000 - 2006
RECORD_ID
PR0231035
PE
2361
FACILITY_ID
FA0006773
FACILITY_NAME
ARCO 02186
STREET_NUMBER
3212
Direction
N
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
STOCKTON
Zip
95204
APN
12532001
CURRENT_STATUS
01
SITE_LOCATION
3212 N CALIFORNIA ST
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
391
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITC_.ING SYSTEM CERTIFICA Z)N <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6.7. Health and Safety Code:Chapter 16, Division 3 Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility,a separate <br /> certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: ARCO#02186,CC 18022645 City: STOCKTON CA Zip:95210 <br /> Site Address: 3212N.CALIFORNIA Contact Phone No: 941-2694 <br /> PTO#N-79 Date of Testing/Service: 10/03/2006 <br /> Facility Contact Person: MGR-KEVIN <br /> Make/Model of Monitoring System:TLS-350 Work Order Number: 2245248 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced <br /> Tank ID: 87 MASTER Tank ID: 87 SYPHON <br /> X In-Tank Gauging Probe. Model: MAG X In-Tank Gauging Probe. Model: MAG <br /> X Annular Space or Vault Sensor. Model: 407 0 Annular Space or Vault Sensor. Model: 407 <br /> X Piping Sump/Trench Sensor(s). Model: 323 A Piping Sumprrrench Sensor(s). Model: 323 <br /> X Fill Sump Sensor(s). Model: 323323 <br /> Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> X Electronic Line Leak Detector. Model: CPT ❑ Electronic Line Leak Detector. Model: <br /> X Tank Overfill/High-Level Sensor. Model: MAG Tank Overfill/High-Level Sensor. Model: MAG <br /> Other(specify equipment type and model in Section E on page 2). ❑ Other(specify equipment type and model in Section E on page 2). <br /> Tank ID: 91 Tank ID: <br /> In-Tank Gauging Probe. Model: MAG In-Tank Gauging Probe. Model: <br /> X Annular Space or Vault Sensor. Model: 407 Annular Space or Vault Sensor, Model: <br /> X Piping Sump/Trench Sensor(s). Model: 323 ❑ Piping Sump/Trench Sensor(s). Model: <br /> X Fill Sump Sensor(s). Model: 323 . <br /> Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> X Electronic Line Leak Detector, Model: CPT Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: MAG <br /> ❑ Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> Dispenser : 1-2 Dispenser ID: 3-4 <br /> 0 Dispenser Containment Sensor(s) Model:323 X Dispenser Containment Sensor(s) Model:323 <br /> X❑Shear Valve(s). _X1Shear Valve(s) <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5-6 Dispenser ID: 7-8 <br /> QDispenser Containment Sensor(s) Model:323 X Dispenser Containment Sensor(s). Model:323 <br /> X❑ Shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). 7 Dispenser Containment Float(s)and Chain(s). <br /> Dispenser lD: Dispenser ID: <br /> ❑ Dispenser Containment Sensor(s) Model: ■ Dispenser Containment Sensor(s). Model: <br /> ❑ Shear Valve(s). ■ Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> 'If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C. Certification <br /> I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this certification is information(e.g manufacturers'checklists)necessary to verify that this information is correct. <br /> and a Site Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached <br /> a copy of the(Check all that apply): ❑System set-up X❑Alarm history repo�rt <br /> Technician Name(print): DENNIS RUE Signature: "7 <br /> Certification No.: 006-05-1510 License.No.: <br /> Testing Company Name:Tanknology Phone No.: (800)800-4633 <br /> Site Address: 8501 N.MoPac Expressway,suite 400,Austin,TX 78759 Date of Testing/Servicing: 10/03/2006 <br /> Monitoring System Certification Page 1 of 3 Based on CA form dated 03/01 <br />
The URL can be used to link to this page