My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2000 - 2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
3212
>
2300 - Underground Storage Tank Program
>
PR0231035
>
COMPLIANCE INFO 2000 - 2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2024 2:39:12 PM
Creation date
3/26/2019 2:45:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2000 - 2006
RECORD_ID
PR0231035
PE
2361
FACILITY_ID
FA0006773
FACILITY_NAME
ARCO 02186
STREET_NUMBER
3212
Direction
N
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
STOCKTON
Zip
95204
APN
12532001
CURRENT_STATUS
01
SITE_LOCATION
3212 N CALIFORNIA ST
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
391
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D. Results of Testing/Servicing, <br />Software Version Installed: <br />Complete the following checklist: <br />C E T Dispatch <br />Yes <br />0 No* <br />Is the audible alarm operational? <br />a'Yes <br />0 No* <br />Is the visual alarm operational? <br />J Yes <br />Er No* <br />Were all sensors visually inspected, functionally tested, and confirmed operational? <br />2—Yes <br />0 No* <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br />not interfere with their proper operation? <br />0 Yes <br />D No* <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br />MI—N/A <br />operational? <br />Yes <br />0 No* <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br />0 N/A <br />monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate <br />positive shut -down? (Check all that apply) ®'Sump/Trench Sensors; ®'Dispenser Containment Sensors. <br />Did you confirm positive shut -down due to'leaks and sensor failure/disconnection? ZI'Y`es; 0 No. <br />0 Yes <br />M'No* <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br />0 N/A <br />mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br />fillpoint(s) and operating properly? If so, at what percent of tank capacity does the alarm trigger? % <br />Q'Yes* <br />E2 No <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced <br />and list the manufacturer name and model for all replacement parts in Section E, below. <br />Yes* <br />U No <br />Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) 0 <br />Product; ❑ Water. If yes, describe causes in Section E, below. <br />Yes <br />0 No* <br />Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable <br />R'Yes <br />0 No* <br />Is all monitoring equipment operational per manufacturer's specifications? <br />* In Semien E bciow, describe how ane y"'hes ttYe r- deficiencies were or V';M he <br />E. Comments: (1, 1, ^1 e <br />c-) <br />Page 2 of 3 <br />Y <br />
The URL can be used to link to this page
Your browser does not support the video tag.