My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WASHINGTON
>
1340
>
1900 - Hazardous Materials Program
>
PR0519595
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/28/2019 11:25:44 AM
Creation date
3/28/2019 11:21:59 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1900 - Hazardous Materials Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0519595
PE
1921
FACILITY_ID
FA0007099
FACILITY_NAME
DURAFLAME WEST
STREET_NUMBER
1340
Direction
W
STREET_NAME
WASHINGTON
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
14530012
CURRENT_STATUS
01
SITE_LOCATION
1340 W WASHINGTON ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PLAN FIELD <br /> (3) Is there drainage of uncontaminated rainwater from diked areas into ❑Yes ❑No DNA ❑Yes ❑No ❑NA <br /> a storm drain or open watercourse? <br /> If YES a Bypass valve normally sealed closed ❑Yes [-]No DNA ❑Yes ❑No DNA <br /> • Retained rainwater is inspected to ensure that its presence will ❑Yes ❑No DNA [-]Yes ❑No ❑NA <br /> not cause a discharge as described in §112.1(b) <br /> • Bypass valve opened and resealed under responsible ❑Yes [:]No [INA ❑Yes [:]No ❑NA <br /> supervision <br /> • Adequate records of drainage are kept; for example, records [:]Yes ❑No JNA ❑Yes [:]No ❑NA <br /> required under permits issued in accordance with 40 CFR <br /> §§122.410)(2)and (m)(3) <br /> (4) For completely buried metallic tanks installed on or after January 10, <br /> 1974(if not exempt from SPCC regulation because subject to all of <br /> the technical requirements of 40 CFR part 280 or 281): <br /> • Provide corrosion protection with coatings or cathodic ❑Yes ❑No ❑NA ❑Yes [_1 No ❑NA <br /> protection compatible with local soil conditions <br /> • Regular leak testing conducted [-]Yes ❑No DNA ❑Yes ❑No ❑NA <br /> (5) The buried section of partially buried or bunkered metallic tanks ❑Yes ❑No DNA ❑Yes ❑No ❑NA <br /> protected from corrosion with coatings or cathodic protection <br /> compatible with local soil conditions <br /> (6) Test or inspect each aboveground container for integrity on a ❑Yes ❑No DNA ❑Yes ❑No [JNA <br /> regular schedule and whenever you make material repairs. <br /> Techniques include, but are not limited to: visual inspection, <br /> hydrostatic testing, radiographic testing, ultrasonic testing, <br /> acoustic emissions testing, or other system of non-destructive <br /> testing <br /> Appropriate qualifications for personnel performing tests and ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> inspections are identified in the Plan and have been assessed <br /> in accordance with industry standards <br /> The frequency and type of testing and inspections are ❑Yes []No —INA Yes ❑No DNA <br /> documented, are in accordance with industry standards and <br /> take into account the container size, configuration and design <br /> • Comparison records of aboveground container integrity testing ❑Yes [:]No DNA ❑Yes [:]No [:INA <br /> are maintained <br /> Container supports and foundations regularly inspected ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Outside of containers frequently inspected for signs of ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> deterioration, discharges, or accumulation of oil inside diked <br /> areas <br /> • Records of all inspections and tests maintained'$ ❑Yes ❑No [:INA ❑Yes [:]No ❑NA <br /> Integrity Testing Standard identified in the Plan: <br /> STI SPoo1 <br /> 112.12 Conduct formal visual inspection on a regular schedule for bulk [-]Yes ❑No ❑NA ❑Yes [:]No ❑NA <br /> (c)(6)(ii) storage containers that meet all of the following conditions: <br /> (Applies to •Subject to 21 CFR part 110; •Have no external insulation;and <br /> AFVO Facilities •Elevated; •Shap-fabricated. <br /> only) •Constructed of austenitic stainless <br /> steel; <br /> In addition, you must frequently inspect the outside of the container -]Yes El No DNA [:]Yes [_]NoDNA <br /> for signs of deterioration, discharges, or accumulation of oil inside <br /> diked areas. <br /> You must determine and document in the Plan the appropriate ❑Yes [:]No DNA ❑Yes [:]No [:INA <br /> qualifications for personnel performing tests and inspections.' <br /> 1 <br /> 5 Records of inspections and tests kept under usual and customary business practices will suffice <br /> Onshore Facilities(Excluding Oil Production) Page 12 of 14 June 2014 <br />
The URL can be used to link to this page
Your browser does not support the video tag.