My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
3212
>
2300 - Underground Storage Tank Program
>
PR0231035
>
COMPLIANCE INFO 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2019 1:29:09 PM
Creation date
3/28/2019 2:24:51 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0231035
PE
2361
FACILITY_ID
FA0006773
FACILITY_NAME
ARCO 02186
STREET_NUMBER
3212
Direction
N
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
STOCKTON
Zip
95204
APN
12532001
CURRENT_STATUS
01
SITE_LOCATION
3212 N CALIFORNIA ST
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
177
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�6imEx-RyA# kc. GR Job# 17204467 <br /> Appendix Vi SWRCB,January 2006 <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited; Chapter B.7,Health and Safety Code;Chapter 16, Division 3, Title 23, Califomia Code of <br /> Regulations <br /> This fort must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work.A copy of this form must be provided to the tank system <br /> ownerloperator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General information <br /> Facility Name: Arco 2186 <br /> Bldg.No.: <br /> Site Address: 3212 N. California city Stockton Zip: 95204 <br /> Facility Contact Person: Daryl Lee Contact Phone No 415.902.5089 <br /> Make/Model of Monitoring System: TLS-350 Date of Testing/Servicing: 1/3/2018 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to Indicate specific equipment Ina tediserviced: <br /> Tank ID: 8 7-1 FE3 <br /> k ID: 8 7-2 <br /> In-Tank Gauging Pmbs. Model: 847390-109 In-Tank Gauging Probe. Model: 847390-109 <br /> v Annular Space or Vault Sensor. Model: 794390-40c) Annular Space or Vault Sensor. Model: 7943 9 0-409 <br /> V Piping Sump/Trench Sensor(s). Model: 7 94 3 8 0-2 0 8 Piping Sump/Trench Sensor(s). Model:'g r 3 8 0-2 0 8 <br /> Fill Sump Sensor(s). Model: 794380-208 Fill Sump Sensor(s). Model:7 94 3 8 0-2 Q'S"8 <br /> Mechanical Line Leak Detector. Model. Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector Model 848480 Electronic Line Leak Detector Mme: <br /> Tank Overfill/High-Level Sensor. Model: VR m Tank Overfill/High-Level Sensor. Model:_VR <br /> Other(specify equipment and model in Section E on P22e 2). ❑ Other sui merit type and model in Section E an Pang 2. <br /> Tank ID: _9 I Tank ID: <br /> i In-Tank Gauging Probe. Model: 847390-109 ❑ In-Tank Gauging Probe. Mom: <br /> Annular Space or Vault Sensor. Model; - ❑ Annular Space or Vault Sensor. Model: <br /> i Piping Sump/Trench Sensor(s). Model: _ ❑ Piping Sump/Trench Sensor(s). Model; <br /> i FRI Sump Sensor(s), Model: 794380-208 ❑ Fill Sump Sensor(s). Mom: <br /> Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model; <br /> r Electronic Line Leak Detector Model: 848480 ❑ Electronic Line Leak Detector Model: <br /> r Tank Overfill/High-Level Sensor. Model: VR ❑ Tank Overfill/High-Level Sensor. Model <br /> Others equipment and model in Section E on Pt 2. ❑ Other equipment type and model in Section E on Pa e 2). <br /> Dispenser ID: 1/2 Dispenser ID: 3/4 <br /> Dispenser Containment Sensor(s). Model: 794380-2080 Dispenser Containment Sensor(s). Model: '794380-208 <br /> r Shear Valve(s). G3 Shear Valve(s). <br /> Dis neer Containment Floors and Chains. 0 DisE2nser Containment Float(s) and Chain(s). <br /> Dispenser ID: 5/6 Dispenser ID: 7/8 <br /> Dispenser Containment Sensor(s). Model: 794380-2080 Dispenser Containment Sensor(s). Model: 794380-208 <br /> r ShearValve(s). 0 Shear Valve(s). <br /> Dispenser Containment Floors and Chain(s). 1112 Dispenser Containment Floors and Chain(s). <br /> Dispenser ID: Dispenser iD. <br /> Dispenser Containment Sensor(s). Model: 17 Dispenser Containment Sensor(s). Model: <br /> Shear Valve(s). 17 Shear Valve(s). <br /> Dise2n3er Containment Float(s) and Chain(s). ❑ Dispenser Containment Float(s) and Chains. <br /> If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C. Certification - I certify that the equipment identified In this document was inspectedleerviced In accordance with the manufacturers' <br /> guidelines. Attached to this Certification Is Information (e.g. manufacturers' checklists) necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment For any equipment capable of generating such reports, 1 have also attached a <br /> copy of the repos;(check all that appty): ❑� system setup 0 Alarm hl fo — <br /> Technician Name(print): Alexander Tate Signature: <br /> Certification No.: B42662 License.No.: 220793 <br /> Testing Company Name: Getder-Ryan Inc. Phone No.: 925-551-7555 <br /> Testing Company Address: 6805 Sierra Court Suite G.,Dublin CA 94568 Date of Testing/Servicing: 1/3/2018 <br /> Monitoring System Certification Page t of 4 12107 <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.