My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
2487
>
2200 - Hazardous Waste Program
>
PR0536716
>
COMPLIANCE INFO PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/8/2025 1:00:49 PM
Creation date
3/29/2019 1:29:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0536716
PE
2220
FACILITY_ID
FA0007270
FACILITY_NAME
california specialty cheese
STREET_NUMBER
2487
Direction
N
STREET_NAME
AIRPORT
STREET_TYPE
Way
City
Manteca
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
2487 N Airport Way
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
247
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.smgov.org/ehd/unitiii.html <br />CONTINUATION FORM <br />Page: 8 of 9 <br />OFFICIAL INSPECTION REPORT <br />Date: 11/09/11 <br />Facility Address: California Specialty Cheese 14253 South Airport Way, Manteca <br />Program: HW <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />407. Empty containers not marked "Empty" and with date it was empty or not managed within 1 year of <br />being emptied. <br />- Dryer Plant: ten white 5 gallon poly containers on metal storage rack <br />- Chemical Building: three 55 gallon poly blue drums <br />- Outdoors by the former waste water treatment system: several 55 gallon metal drums <br />- Outdoor open wooden storage area located NW of property: three 55 gallon poly blue and three 55 <br />gallon poly white drums <br />Containers larger than five gallons that previously held a hazardous material shall be marked with the <br />date they were emptied and managed within one year of being emptied. Since it is unknown how long <br />ago they became empty, immediately properly dispose these containers according to Title 22 hazardous <br />waste regulations. <br />605 & 701. Failed to properly label tanks of HW. Stored HW on site >180 days. <br />- A 240 gallon full of used oil is lacking complete hazardous waste labeling ie. the start accumulation <br />date. All hazardous waste tanks shall be marked with the following information: words "Hazardous <br />Waste" and accumulation start date. Since it is unknown when the first drop of used oil was poured into <br />the used oil tank, immediately contact a licensed hazardous waste hauler to dispose of this waste under <br />manifest and submit a copy of the manifest to the EHD. <br />- Corrected on site. Received copy of hauler George R. Lowry Inc pick up on 11/16/2011. <br />Requesting spill pallets moved indoors to prevent rain -water accumulation, generating oil -water waste. <br />605 & 701. Failed to properly label containers of HW. Stored HW on site >180 days <br />- Outdoor adjacent to 240 gallon used oil tank: on the spill pallets, ten 5 gallon containers, one 55 gallon <br />metal drum and one 20 gallon poly container <br />- Outdoors Compressor area: a broken white poly container storing dark oily liquid and one large light <br />bulb found in a blue poly 55 gallon drum <br />- Outdoors Compressor area: Quincysep Oil/Water Separator is discharging oily yellow liquid into a 5 <br />gallon open container <br />- Outdoors Chemical Storage area: one 55 gallon poly white drum storing dark oily substance, two 55 <br />gallon poly blue drums of unknown contents; on spill pallet: 5 gallon white container storing yellow color <br />liquid, open 5 gallon yellow bucket storing 1/3 full of dark oily liquid <br />- Outdoors by the former waste water treatment system: one white poly 55 gallon storing 1/3 dark liquid, <br />two blue 55 gallon open top drums laying on its side storing white hard foamy substance <br />- Ammonia Compressor room: oily absorbent on the floor adjacent to the bucket and pan of used oil <br />- Outdoors by former waste water treatment system: several 55 gallon poly drums of unknown contents <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIM T EHD'S CURRENT HOURLY RATE. <br />EHD Inspector: <br />Thuy Tran (209) 468-8257 <br />tReceiyey: <br />Title: <br />EHD 23-02-003 Rev 07/12/11 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.