My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REMOVAL 1995
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CAPITOL
>
6421
>
2300 - Underground Storage Tank Program
>
PR0231706
>
REMOVAL 1995
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/11/2019 3:52:02 PM
Creation date
4/10/2019 11:09:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
REMOVAL
FileName_PostFix
1995
RECORD_ID
PR0231706
PE
2361
FACILITY_ID
FA0000485
FACILITY_NAME
FLAG CITY CHEVRON
STREET_NUMBER
6421
STREET_NAME
CAPITOL
STREET_TYPE
AVE
City
LODI
Zip
95242
APN
05532024
CURRENT_STATUS
01
SITE_LOCATION
6421 CAPITOL AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
172
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
P�S�uq eg c <br />STATE OF CALIFORNIA s <br />STATE WATER RESOURCES CONTROL BOARD <br />UNDERGROUND STORAGE TANK PERMITAPPLICATION - FORM B :� 'a° <br />COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. �-k"o. <br />MARK ONLY ❑ 1 NEW PERMIT <br />❑ <br />3 RENEWAL PERMIT <br />❑ 5 CHANGE OF INFORMATION <br />❑ 7 PERMANENTLY CLOSED ONSITE <br />ONE ITEM ❑ 2 INTERIM PERMIT <br />❑ <br />4 AMENDED PERMIT <br />❑ 6 TEMPORARY TANK CLOSURE <br />8 TANK REMOVED <br />DBA OR FACILITY NAME WHERE TANK IS INSTALLED: <br />Saddle City <br />Chevron - 6241 W. Paddock Place, Lodi <br />I. TANK DESCRIPTION COMPLETE ALL ITEMS - SPECIFY IF UNKNOWN <br />A. OWNER'S TANK I. D. A 2 <br />B. MANUFACTURED BY: <br />Arrow <br />C. DATE INSTALLED (MO/DAY/YEAR) 1983 <br />D. TANK CAPACITY IN GALLONS: <br />12,000 <br />ILTANKCONTENTS IFA -1 IS MARKED. COMPLETE ITEM C. <br />A. = 1 MOTOR VEHICLE FUEL ❑ 4 OIL <br />8. <br />C. 1a REGUL R ❑ 3 DIESEL ❑ 6 AVIATION GAS <br />❑ 4 GASAHOL <br />❑ 2 PETROLEUM ❑ 80 EMPTY <br />1 PRODUCT <br />❑ 1b PREMIUM ❑ 7 METHANOL <br />UNLEADED ❑ 5 JET FUEL <br />❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN <br />❑ 2 WASTE <br />❑ 2 LEADED ❑ 99 OTHER (DESCRIBE IN ITEM D. BELOW) <br />D. IF (A.1) IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C. A. S. # <br />III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN ROXFS A R ANO C ANn AI I THAT APPI IFS IN ROX n ANn F <br />A. TYPE OF <br />❑ 1 DOUBLE WALL <br />❑ 3 SINGLE WALL WITH EXTERIOR LINER <br />❑ 95 UNKNOWN <br />SYSTEM <br />IV 2 SINGLE WALL <br />❑ 4 SECONDARY CONTAINMENT (VAULTED TANK) <br />❑ 99 OTHER <br />B. TANK <br />0/1 BARE STEEL <br />❑ 2 STAINLESS STEEL <br />❑ 3 FIBERGLASS <br />❑ 4 STEEL CLAD W/ FIBERGLASS REINFORCED PLASTIC <br />MATERIAL <br />❑ 5 CONCRETE <br />❑ 6 POLYVINYL CHLORIDE <br />❑ 7 ALUMINUM <br />❑ 8 100% METHANOL COMPATIBLE W/FRP <br />(PrirnaryTank) <br />❑ 9 BRONZE <br />❑ 10 GALVANIZED STEEL <br />❑ 95 UNKNOWN <br />❑ 99 OTHER <br />❑ 1 RUBBER LINED <br />❑ 2 ALKYD LINING <br />❑ 3 EPDXY LINING <br />❑ 4 PHENOLIC LINING <br />C. INTERIOR <br />❑ 5 GLASS LINING�6 <br />UNLINED <br />F-195 UNKNOWN <br />❑ 99 OTHER <br />LINING <br />IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? <br />YES _ NO <br />D. CORROSION <br />❑ 1 POLYETHYLENE WRAP <br />❑ 2 COATING <br />❑ 3 VINYL WRAP <br />❑ 4 FIBERGLASS REINFORCED PLASTIC <br />PROTECTION <br />❑ 5 CATHODIC PROTECTION <br />❑ 91 NONE <br />©95 UNKNOWN <br />❑ 99 OTHER <br />E. SPILL AND OVERFILL SPILL CONTAINMENT INSTALLED (YEAR) <br />OVERFILL PREVENTION EQUIPMENT INSTALLED (YEAR) <br />IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND. BOTH IF APPLICABLE <br />A. SYSTEM TYPE <br />A U <br />1 SUCTION <br />A U <br />2 eeitA U <br />3 GRAVITY A U 99 OTHER <br />B. CONSTRUCTION <br />A U <br />1 dGL LL <br />A U <br />2 DOUBLE WALL A U <br />3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br />C. MATERIAL AND <br />CORROSION <br />PROTECTION <br />A U <br />A U <br />A U <br />1 BARE STEEL <br />5 ALUMINUM <br />9 GALVANIZED STEEL <br />A U <br />A U <br />A U <br />2 AI SSS EL A U <br />6 CONCRETE A U <br />10 CATHODIC PROTECTION <br />3 POLYVINYL CHLORIDE (PVC)A U <br />7 STEEL W/ COATING A U <br />A U 95 UNKNOWN A U <br />4 FIBERGLASS PIPE <br />8 100% METHANOL COMPATIBLE W/FRP <br />99 OTHER <br />D. LEAK DETECTION <br />❑ 1 <br />AUTOMATIC LINE LEAK DETECTOR ❑ 2 LINE TIGHTNESS TESTING ❑ 3 MONR'ORING <br />❑ 99 OTHER <br />V. TANK LEAK DETECTION <br />_ I 1 VISUAL CHECK ❑ 2 INVENTORY RECONCILIATION F-13 VADOZE MONITORING E]4 AUTOMATIC TANK GAUGING �� 5 GROUND WATER MONITORING <br />/6 TANK TESTING ❑ 7 INTERSTITIAL MONITORING ❑ 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br />VI. TANK CLOSURE INFORMATION <br />1. ESTIMATED DATE LAST USED (MO/DAY/YR) 2. ESTIMATED QUANTITY OF 3. WAS TANK FILLED WITH YES ❑ NO ❑ <br />SUBSTANCE REMAINING GALLONS INERT MATERIAL? <br />THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY, AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br />APPLICANTS NAME ATE <br />(PRINTED d SIGNATURE) Michael S. Ramos 7-29-94 <br />'--- J <br />LOCAL AGENCY USE ONLY THE STATE 1. D. NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br />COUNTY # JURISDICTION # FACILITY # TANK # <br />STATE I.D.# ❑ ❑❑ <br />PERMIT NUMBER PERMIT APPROVED BY/DATE PERMIT EXPIRATION DATE <br />FORM B (7-91) THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION - FORM A, UNLESS A CURRENT FORM A HAS BEEN FILED. <br />FOR0034B-R5 <br />