Laserfiche WebLink
�,oURCe <br />STATE OF CALIFORNIA 4.P �Ot <br />STATE WATER RESOURCES CONTROL BOARD <br />UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B o= <br />COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br />MARK ONLY ❑ 1 NEW PERMIT <br />❑ <br />3 RENEWAL PERMIT <br />❑ 5 CHANGE OF INFORMATION <br />❑ <br />7 PERMANENTLY CLOSED ON SITE <br />ONE ITEM ❑ 2 INTERIM PERMIT <br />❑ <br />4 AMENDED PERMIT <br />❑ 6 TEMPORARY TANK CLOSURE <br />Y2 <br />8 TANK REMOVED <br />DBA OR FACILITY NAME WHERE TANK IS INSTALLED: <br />Saddle City <br />Chevron - 6241 W. Paddock <br />Plcae, Lodi <br />1. TANK DESCRIPTION COMPLETE ALL ITEMS -- SPECIFY IF UNKNOWN <br />A. OWNER'S TANK I.D.# 3 B. MANUFACTURED BY: Arrow <br />C. DATE INSTALLED (MO/DAYNEAR)l 9 8 3 D. TANK CAPACITY IN GALLONS: 12,000 <br />II_ TANK CONTENTS IP A.1 I.4MARKP:nrnMPIPTP ITPMC <br />A. [a 1 MOTOR VEHICLE FUEL ❑ 4 OIL <br />B. <br />❑ laREGULAR <br />C.❑ 3 DIESEL ❑ 6 AVIATION GAS <br />UNLEADF-1b <br />2 PETROLEUM ❑ 80 EMPTY <br />1 PRODUCT <br />iPREMIUM ❑ 4 GASAHOL ❑ 7 METHANOL <br />UNLEADED ❑ 5 JET FUEL <br />❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN <br />❑ 2 WASTE <br />❑ 2 LEADED ❑ 99 OTHER (DESCRIBE IN ITEM D. BELOW) <br />D. IF (A.1) IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C. A. S. #: <br />III. TANK CONSTRUCTION MARK ONE ITFM nNI Y IN ROXPS A R ANIS C ANI) Al I TWAT APPI IFR IN Rl1X rl ANII C <br />A. TYPE OF <br />❑ 1 DOUBLE WALL <br />❑ 3 SINGLE WALL WITH EXTERIOR LINER <br />❑ 95 UNKNOWN <br />SYSTEM <br />5�11 2 SINGLE WALL <br />❑ 4 SECONDARY CONTAINMENT (VAULTED TANK) <br />❑ 99 OTHER <br />B. TANK <br />Z'1 BARE STEEL <br />❑ 2 STAINLESS STEEL <br />❑ 3 FIBERGLASS <br />❑ 4 STEEL CLAD W/ FIBERGLASS REINFORCED PLASTIC <br />MATERIAL <br />❑ 5 CONCRETE <br />❑ 6 POLYVINYL CHLORIDE <br />❑ 7 ALUMINUM <br />❑ 8 1009/6 METHANOL COMPATIBLE W/FRP <br />(Primary Tank) <br />❑ 9 BRONZE <br />❑ 10 GALVANIZED STEEL <br />❑ 95 UNKNOWN <br />❑ 99 OTHER <br />AUTOMATIC LINE LEAK DETECTOR ❑ 2 LINE TIGHTNESS TESTING E]3 <br />❑ 1 RUBBER LINED <br />❑ 2 ALKYD LINING <br />❑ 3 EPDXY LINING <br />❑ 4 PHENOLIC LINING <br />C. INTERIOR <br />❑ 5 GLASS LINING <br />EP -16 UNLINED <br />❑ 95 UNKNOWN <br />n 99 OTHER <br />LINING <br />IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? <br />YES NO <br />D. CORROSION <br />❑ 1 POLYETHYLENE WRAP <br />❑ 2 COATING <br />❑ 3 VINYL WRAP <br />❑ 4 FIBERGLASS REINFORCED PLASTIC <br />PROTECTION <br />❑ 5 CATHODIC PROTECTION ❑ 91 NONE <br />�5 UNKNOWN <br />❑ 99 OTHER <br />E. SPILL AND OVERFILL SPILL CONTAINMENT INSTALLED (YEAR) <br />OVERFILL PREVENTION EQUIPMENT INSTALLED (YEAR) <br />IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND. ROTHIFAPPLICABLE <br />A. SYSTEM TYPE <br />A U <br />1 SUCTION <br />A U <br />2 RES 9E A U <br />3 GRAVITY <br />A U 99 OTHER <br />B. CONSTRUCTION <br />A U <br />1 I F L <br />A U <br />2 DOUBLE WALL A U <br />3 LINED TRENCH <br />A U 95 UNKNOWN A U 99 OTHER <br />C. MATERIAL AND <br />CORROSION <br />PROTECTION <br />A U <br />A U <br />A U <br />1 BARE STEEL <br />5 ALUMINUM <br />9 GALVANIZED STEEL <br />A UAI <br />A U <br />A U <br />LESSS A U <br />6 CONCRETE A U <br />10 CATHODIC PROTECTION <br />3 POLYVINYL CHLORIDE (PVC) A U <br />7 STEEL W/COATING A U <br />A U 95 UNKNOWN A U <br />4 FIBERGLASS PIPE <br />8 1009/6 METHANOL COMPATIBLE W/FRP <br />99 OTHER <br />D. LEAK DETECTION <br />❑ 1 <br />AUTOMATIC LINE LEAK DETECTOR ❑ 2 LINE TIGHTNESS TESTING E]3 <br />MONITORING <br />❑ 99 OTHER <br />V. TANK LEAK DETECTION <br />1 VISUAL CHECK ❑ 2 INVENTORY RECONCILIATION ❑ 3 VADOZE MONITORING ❑ 4 AUTOMATIC TANK GAUGING ❑ 5 GROUND WATER MONITORING <br />6 TANK TESTING ❑ 7 INTERSTITIAL MONITORING ❑ 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br />VI. TANK CLOSURE INFORMATION <br />1. ESTIMATED DATE LAST USED (MO/DAY/YR) 2. ESTIMATED QUANTITY OF 3. WAS TANK FILLED WITH <br />SUBSTANCE REMAINING GALLONS INERT MATERIAL? YES ❑ NO <br />THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY, AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br />APPLICANTS NAME DATE <br />(PRINTED A SIGNATURE) //f�/J Michael S. Ramos 7-29-94 <br />LOCAL AGENCY USE ONLY THE ST ATF I.D. NUMEER IS COMPOSED OF THE FOUR NUMBERS BELOW <br />COUNTY # JURISDICTION # FACILITY # TANK # <br />STATE I.D.# ❑ I I 111F] 11111111 <br />PERMIT NUMBER PERMIT APPROVED BY/DATE PERMIT EXPIRATION DATE <br />FORM B (7-91) THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION - FORM A, UNLESS A CURRENT FORM A HAS BEEN FILED. <br />FOR0034 B -RS <br />