Laserfiche WebLink
REVISIONS BY <br /> PLUMBING FIXTURE SCHEDULE <br /> MARK MAKE/MODEL TRIM ACCESS❑RIES <br /> 4# LEAD JACKET - <br /> HWS-1 ADVANCE-TABC❑ <br /> 10"x14"x5" SINK BOWL WITH SOAP DISPENSER, PAPERS❑WEL HOT MOP INTO ROOF <br /> 7-PS-40 DISPENSER, 2 WELDED 7-3/4" HIGH SIDE SPLASHES, SPLASH BEND TOP OVER PIPE AND <br /> EXTEND 2" INTO OPENING MANHOLE EXTENSTI❑NS <br /> MOUNTED 4"0,C, GOOSENECK FAUCET W/ AERATOR AND BUILT-IN AOR, AS REQUIRE <br /> OVERFLOW, RUBBER RING FLASHING FINSIHED FLOOR, ROADWAY, <br /> 3CS-1 REGENCY 3 COMPARTMENT POT SINK COMPLETE WITH (2)REGENCY 15" SWING AND CLAMP FOR METAL ROOFS W/ OR GRADE SET TANK 12' <br /> HOSE CLAMP AROUND PIPE EXTEND 6" AFR MIN BELOW FINISHED GRADE rcG; <br /> '0 CAST IRON MANHOLE <br /> 600S3141414C SPOUTS, 14x14 SINK BASINS, 2-14 DRAIN B❑ARDS, FINISHED ROOF — SEE ARCH VERS ANDFRAMES <br /> DWGS — FLASHING INSTALLATION SHALL S TIGHT AND LABELED <br /> n MATCH ROOFING MANUFACTURERS EASE <br /> FD-1 ZURN ZN415 TYPE B STRAINER FL❑❑R DRAIN, 2 OUTLET, TRAP PRIMER FITTING, DETAILSTO MAINTAIN WARRANTYFS-1 ZURN 12x12 SANI-FL❑R RECEPTOR W/ALUM D❑ME STRAINER, MOUNT LIP 1" - I 17' MIIII-IIIIII- <br /> Z-1900-P-2-32 AFF, 2" OUTLET, TTACH SUPPORT T❑ BLOCKING <br /> W/J' LAGS FOR WOOD <br /> IWH-1 TAKAGI TK-4 SINGLE POINT USE INSTANTANE❑US HOT WATER HEATER, MODEL TK4, - #8x1— 'sM SCREW FOR STEEL ' OUTLET w <br /> 4 GPM, 80°F RISE, 120V, lk 190 MBH INPUT, SET LEAVING WATER JENSEN 750 GALLON J (n <br /> TEMP AT 120°F MAX. GREASE INTERCEPT❑R <br /> BLOCKING AS JP750EE—G MIN LOAD D LLJ <br /> " REQUIRED CAPATANKCSHALL BE SUITABLE FOR <br /> Q <br /> GT-1 JENSEN H-20 TRAFFIC RATED 750 GALLON GREASE INTERCEPTOR, 2-24"0 PR❑VIDE PEA GRAVEL IN UP 6' ❑F COVER Q <br /> PRECAST CAST IR❑N GASKETED MANHOLE COVERS AND GRADE RINGS AS BOTTOM AND ALL OTHER W z <br /> CUT OPENING IN ROOF <br /> PRODUCTS REQUIRED FOR 18" DEPTH OF BURY FROM FLATW❑RK/GRADE, TWO FILL MATERIALS PER MINIMUM 2" LARGER THAN PIPE PEA GRAVEL AROUND TANK <br /> JP750EPE-G COMPARTMENTS WITH 4" INLET AND OUTLET. DETAIL 1/PO OF REFER TO STRUCTURAL/ARCG DWGS SET TANK ❑N 4" THICK SAND BASE _ <br /> 18 GA PIPE BRACE IF OPENING IS LARGER THAN 8"0 U 0 <br /> WITHIN10 <br /> DECK22y REQUIRED PIPE UP THROUGH 750 GAL GREASE TRAP l U) z <br /> ROOF <br /> DETAIL PO J V <br /> PIPE CLAM 7 �^� <br /> ~ Z VJ <br /> VENT F LASHING6 PLUG 2" BELOW FINISH ~ W J <br /> PLUMBING LEGEND DETAIL PO GRADE OR FLOOR CD <br /> o ROAD PAVEMENT WHERE <br /> SYMBOL DESCRIPTION SYMBOL 7 <br /> DESCRIPTION APPLICABLE < J W <br /> 6" THICK 36" DIAMETER <br /> --- CW COLD WATER LINE �� BALL VALVE <= 4", GATE VALVE>4" 1 ONCRETE RING WITH p Q <br /> —#4 BAR IN CENTER <br /> ---- HW HOT WATER LINE BALANCING VALVE CONCRETE BOX LABELED SEWER <br /> OR' <br /> BRASS CLEANOUT BOX <br /> I I I I I I I I I I I TD TRENCH DRAIN GAS COCK <br /> IN FINISHED FLOOR <br /> SS SANITARY SEWER AC ABOVE CEILING 6"0 PVC SLEEVE WITH 4"0 +. <br /> CLEANOUT RISER PIPE U) <br /> GL GREASE LINE BFF BELOW FINISHED FLOOR m <br /> LONG SWEEP 'L' (� � m <br /> 90 DEGREE z C -0 <br /> — HV HORIZONTAL VENT AFF ABOVE FINISHED FLOOR INVERT — SEE PLAN - 6)"t O <br /> FOR SIZES ( W N O O 0) <br /> -SD— STORM DRAIN LINE BFG BELOW FINISHED GRADE SEE PLUMBING FLOOR z >+ "t CO o0 -0 <br /> —C— CONDENSATE DRAIN MV MIXING VALVE PLAN FOR SIZE W '� cn Lo ti r1 <br /> � � � N O O <br /> — MA — MEDICAL/DENTAL AIR WC WATER CLOSET CLEANOUT TO GRADE 2 z U) co M .L <br /> � •- Urnrn � <br /> —V — VACUUM UR URINAL DETAIL PO z a 15 N o <br /> WU N J L m E <br /> V, VR, VTR VENT, VENT RISER, VENT THRU ROOF L LAVATORY 0 -- <br /> PLUG 2" BELOW FINISH � N O <br /> —SSD — SANITARY SEWER DROP S SINK <br /> GRADE OR FLOOR D � — <br /> U o ca <br /> RWL RAIN WATER LEADER MS SERVICE/MOP SINK oROAD PAVEMENT WHERE 2: E <br /> APPLICABLE U j <br /> RD ROOF DRAIN DF DRINKING FOUNTAIN 6" THICK 36" DIAMETER <br /> ONCRETE RING WITH <br /> AD AREA DRAIN FHS FIRE HOSE STANDPIPE 1—#4 BAR IN CENTER <br /> CONCRETE BOX LABELED SEWER <br /> CB, DI CATCH BASIN (DROP INLET) INV INVERT ELEVATION 'OR' <br /> BRASS CLEANOUT BOX <br /> CO CLEAN OUT FG FINISH GRADE <br /> IN FINISHED FLOOR <br /> 6"0 PVC SLEEVE WITH 4"0 <br /> I� WCO WALL CLEAN OUT CUT OFF POINT - COP _% D CLEANOUT RISER PIPE <br /> FCO FLOOR CLEAN OUT POINT OF CONNECTION - POC 320-5000 GALLON <br /> 2WAY CI IAPMO <br /> YCO YARD CLEAN OUT AD ACCESS DOOR - SEE SCHEDULE FOR TYPES GREASE INTERCEPTORS APPROVED CLEANOUT <br /> NORTHERN CALIFORNIA INVERT SEE PLAN <br /> FD FLOOR DRAIN CI CAST IRON <br /> B FOR SIZES S <br /> SEE PLUMBING FLOOR <br /> FS FLOOR SINK CENTER LINE -1 <br /> r � PLAN FOR SIZE N <br /> TP TRAP PRIMER VALVE HDR HEADER I I 2—WAY CLEANOUT 3 T_ <br /> CW, D, R — COLD WATER (DROP) (RISER) DN DOWN C�A DETAIL PO w <br /> HW,D,R,RT — HW SUPPLY (DROP) (RISER) (RETURN) MBH THOUSANDS OF BTU PER HOUR <br /> IL J J 4"FLUE Q <br /> THW —T — TEMPERED HOT WATER (115° F) NIPC NOT IN PLUMBING CONTRACT TOP VIEW (COVERS AND RINGS REMOVED) THRU ROOF <br /> LLI z <br /> — G, LPG — NATURAL GAS (PROPANE)<5PS1 HW HAND WASH STATION 24" CAST IRON FRAMES AND COVERS 3". 6" AND 120 z <br /> WITH GASKET (GASTIGHT) STANDARD GR2432 GRADE RINGS IWH-1 CW/HW J O <br /> — HPG — HIGH PRESSURE GAS(PROPANE) >5PS1 HS HOSE STATION PWG* AT EXTRA COST AP PINGS W Q LL <br /> oFmh/ MOUNT 48' 0 - <br /> - CA — HWG H L.L <br /> xr <br /> ;q KAM <br /> HB HOSE BIBB BV BALL <5", BUTTERFLY >5" VALVE amar C LJ,J U <br /> • G 2 <br /> P UNDER PLUMBING CONTRACT SCW SOFT COLD WATER LINE C 4 PIPE AND FITTINGS <br /> O D STANDARD E 3/4' T&P INTEGRAL `J.J 5 7 <br /> SOV SHUT OFF VALVE — SHW — SOFT HOT WATER LINE <br /> RELIEF — FLEX ASSEMBLY z <br /> SPILL 6'AFG Q O <br /> �• .• .• Z <br /> SIDE SECTION VIEW *EXCEPT MODELS 320 & 500 = � <br /> 1' H&CW LINES FGINE — SEET❑ IWH-1 6' DRIP LEGF❑R SIZES = W <br /> MODEL <br /> LIQUID MINIMUM MINIMUM DEPTH OF LINE SIZE <br /> AND ROUTING U <br /> FIXTURE CONNECTION SCHEDULENUMBER BURY CAPACITY DIM A DIM B DIM C DIM D DIME EXCAVATION EXCAVATION M <br /> __D U OO O <br /> (GALLONS) WIDTH LENGTH � <br /> PLUMBING SANITARY WATER JP320EE-G 320 3'-0" 7'-0" 4'-6" 3'-r 3'-4" 4'-0" 8'-0" 1' To 8' IWH-1 PIPING DETAIL 4 p CD <br /> FIXTURE SEWER VENT COLD H❑T JP500EE-G 500 4'-0" 6'-0" 5'-10" 4'-10" 4'-r 5'-0" 7'-0" V TO 6' DETAIL P 0 12:� O <br /> WATER CLOSET F V 3# 2" 11 <br /> - JP750EPE-G 750 4'-0" 8'-1" 6'-3" V-0' 4'-9" 5'-3" 9'-1" 1' TO 6' a co <br /> WATER CLOSET F T 3# 2# 112# - JP1000EPE-G 1000 5'-1" 8'-2" 6'-3" 5'-0" 4'-9" 6'-4" 9'-2" 1' TO 6' <br /> JP1200EPE-G 1200 5'-9" W-6" 6'-6" 5'-0" 4'-9" 7'-0" 9'-6" 1' TO 6' <br /> URINAL F V 2" 1-112# 3/4# - JP1500EPE-G 1500 5'-r 10'-8' 6'-3" 5'-0' 4'-9" 6'-10" 11'-8" 1' TO 6' <br /> URINAL FT 2" 1-1/2" 1/2" - • ! • • • <br /> JP2000EPE-G 2000 4-11 15-11 6-0 5-0 4-9 5-11 16-11 11 TO 6 <br /> LAV 2" 1-1/2" 1/2" 1/2" R2500EPE-G 2500 5'-9" 16'-10" 6'-O" 5'-0" 4'-9" 6'-9" 17'-10" 1' TO 5' POSITIVE FLOW <br /> i r WEATHERT❑P OR FLUE CAP <br /> BAR SINK 2n 1-1/2# 1/2n 112# JZ3000EPE-G 3000 5'-g* <br /> 16-10 6-9 5-9r 5i-6r 6i-9t 17'-10r 1 TO 5� <br /> JZ4000EPE-G 4000 7'-8" 16'-7' 6'-9" 5'-6" 5'-3" 8'-8" 17'—r 1' TO 5' C❑UNTERFLASHING S�O N A� F <br /> CLASSROOM SINK 2" 1-1/2" 1/2" 1/2" ��, G G � <br /> JZ5000EPE-G 5000 7'-8" 16'-7' 7'-11" 6'-9" 6'-6" 8'-8" 17'-r 1' TO V 1' CLEAR SPACE <br /> KITCHEN SINK 2" 1-1/2" 1/2" 1/2" qL 2 <br /> BETWEEN JACK AN <br /> MOP SINK 3" 2" 3/4" 3/4" <br /> DESIGN LOAD: H-20 TRAFFIC WITH DRY SOIL CONDITIONS (WATER LEVEL BELOW TANK.) FLUE/DUCT <br /> TRAP PRIMER - - 1/2" - FINISH R❑❑FING - ROLL <br /> FD - 2" 2" 1-1/2" - - BEDDING NOTE: SUITABLE SUB-BASE BEDDED WITH GRANULAR MATERIAL SHALL BE UP JACK AND ATTACH <br /> FD - 3" 3" 2" - - PREPARED TO HANDLE ANTICIPATED LOADS. UNDER C❑UNTERFLASHING 12' U) NO. M29759 Q <br /> n n n ROOF JACK — 24 GA REN. 6-30-20 <br /> FLOOR SINK 2 2 1-1/2 - - FOR COMPLETE DESIGN AND PRODUCT INFORMATION NAIL TO ROOF W/ MIN <br /> FLOOR SINK 3" 3" 1-1/2" - - 4-2'104 NAILS \�O <br /> „ " CONTACT JENSEN PRECAST. ti.oat n.m..e»�m�. m~� F OF C N <br /> SHOWER - RES, 2 1-1/2 1/2 1/2 fEfffjF/1EYEWASH 2" 1-1/2" 1/2" - 02Wlll� Proomt Y "'~° � '� CAST <br /> SEE STRUCT DWGS <br /> FOR TRUSSES <br /> DRAWN <br /> 2x BLOCKING BY NR <br /> CHECKED <br /> FLUE OR ROUND _ GD <br /> EXH. DUCT <br /> DATE <br /> 03-26-19 <br /> 4 - 12 "0 DUCT THRU R❑❑F 5 SCALE <br /> DETAIL PO AS NOTED <br /> JOB NO. <br /> 2019-030 <br /> SHEET <br />