My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2001 - 2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
2448
>
2300 - Underground Storage Tank Program
>
PR0231948
>
COMPLIANCE INFO 2001 - 2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/19/2022 9:19:58 AM
Creation date
4/26/2019 4:27:45 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001 - 2006
RECORD_ID
PR0231948
PE
2361
FACILITY_ID
FA0003855
FACILITY_NAME
TESORO (SHELL) 68153
STREET_NUMBER
2448
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
05814001
CURRENT_STATUS
01
SITE_LOCATION
2448 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
335
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONIT07ANG SYSTEM CERTIFe"ATION <br /> MAKE / MODEL. OF MONITORING SYSTEM: Veeder-moot TLS-350 <br /> CERTIFICATION / TEST DATE: July 28, 2006 <br /> A1. FACILITY A2. OWNER <br /> Name USA Petroleum #3696 Name USA Petroleum Corporation <br /> Address 2448 W. Kettleman Ln., Lodi,CA 95242 Address 3034 N.Glacier Way, Hanford, CA 93230 <br /> Phone# 559-585-8156 Phone# 559-585-8156 <br /> Contact Sandy Edwards Contact Sandy Edwards <br /> A3. C U P A A4. TESTING CONTRACTOR <br /> Name San Joaquin County Environmental Health Name Walton Engineering, Inc. <br /> Address 304 E Weber Avenue, 3rd Floor, Stockton,CA 95202 Address P.O. Box 1025,W.Sacramento,CA 95691 <br /> Notified July 26,2006 Lic# 617238 A, B, Haz <br /> Inspector Lori Luces Contact Richard Walton <br /> Phone# 209-468-9847 Phone# 916-825-3203 <br /> B. INVENTORY OF EQUIPMENT TESTED/CERTIFIED (check the appropriate boxes to indicate equipment inspectedlserviced) <br /> 131: TANKS <br /> Tank#1 (Product): Tank#2 (Product): Gasoline-89 <br /> ❑ In-Tank Gauging Probe Model: ❑ In-Tank Gauging Probe Model: <br /> ❑ Annular Space or Vault Sensor Model: ■ Annular Space or Vault Sensor Model: 0794390.409 <br /> ❑ Piping Sump 1 Trench Sensor(s) Model: ❑ Piping Sump I Trench Sensor(s) Model: <br /> ❑ Fill Sump Sensor(s) Model: ❑ Fill Sump Sensor(s) Model: <br /> ❑ Mechanical Line Leak Detector Model: ❑ Mechanical Line Leak Detector Model: <br /> ❑ Electronic Line Leak Detector Model: ❑ Electronic Line Leak Detector Model: <br /> ❑ Tank Overfill/High-Level Sensor Model: ❑ Tank Overfill/High-Level Sensor Model: <br /> ❑ Other (specify equipment in Section E) Model: ❑ Other (specify equipment in Section E) Model: <br /> Tank#3 (Product): Tank#4 (Product): <br /> ❑ In-Tank Gauging Probe Model: ❑ In-Tank Gauging Probe Model: <br /> ❑ Annular Space or Vault Sensor Model: ❑ Annular Space or Vault Sensor Model: <br /> ❑ Piping Sump I Trench Sensor(s) Model: ❑ Piping Sump I Trench Sensor(s) Model: <br /> ❑ Fill Sump Sensor(s) Model: ❑ Fill Sump Sensor(s) Model: <br /> ❑ Mechanical Line Leak Detector Model: ❑ Mechanical Line Leak Detector Model: <br /> ❑ Electronic Line Leak Detector Model: ❑ Electronic Line Leak Detector Model: <br /> ❑ Tank Overfill/High-Level Sensor Model: ❑ Tank Overfill/High-Level Sensor Model: <br /> ❑ Other (specify equipment in Section E) Model: ❑ Other (specify equipment in Section E) Model: <br /> B2: DISPENSERS/UDC's <br /> #: Dispenser# <br /> IDispenser <br /> :1Dispenser Containment Sensor(s) Model: E) Dispenser Containment Sensor(s) Model: <br /> ElShear Valves ElShear Valves <br /> ❑ Dispenser Containment Float(s)and Chaln(s) ❑ Dispenser Containment Float(s)and Chains) <br /> Dispenser#: Dispenser# <br /> ❑ Dispenser Containment Sensor(s) Model: ❑ Dispenser Containment Sensor(s) Model: <br /> ❑ Shear Valves ❑ Shear Valves <br /> ❑ Dispenser Containment Float(s)and Chain(s) ❑ Dispenser Containment Float(s)and Chain(s) <br /> Dispenser#: Dispenser# <br /> ❑ Dispenser Containment Sensor(s) Model: ❑ Dispenser Containment Sensor(s) Model: <br /> ❑ Shear Valves ❑ Shear Valves <br /> ❑ Dispenser Containment Float(s)and Chain(s) ❑ Dispenser Containment Float(s)and Chain(s) <br /> C. CERTIFICATION I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct and a Plot Plan showing the <br /> layout of monitoring equipment. For any equipment capable of generating such reports,I have also attached a copy of the report; (check all that apply): <br /> ❑ System set-up ❑ Alarm History Report <br /> WALTON._ <br /> Signature: � ENGINEERING,INC. <br /> Technician I Cert#: Mauricio Miranda/A27938 Date: .Juin 28, 2006 <br /> 2006 Walton Engineering,Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.