My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2007 - 2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
2448
>
2300 - Underground Storage Tank Program
>
PR0231948
>
COMPLIANCE INFO 2007 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/19/2022 9:31:54 AM
Creation date
4/29/2019 9:19:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007 - 2009
RECORD_ID
PR0231948
PE
2361
FACILITY_ID
FA0003855
FACILITY_NAME
TESORO (SHELL) 68153
STREET_NUMBER
2448
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
05814001
CURRENT_STATUS
01
SITE_LOCATION
2448 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
346
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FEB-20-2008 09:04 Service Station Systems 408 938 8888 P.08 <br /> S. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps ❑ <br /> Fill Riser Containment Sumps are Present,but were Not Tested 0 <br /> Test Method Developed By: ❑ Sump Manufacturer 0 Industry Standard ❑Professional Engineer <br /> Q Other(Specify) <br /> Test Method Used: p Pressure ❑Vacuum ® Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used: Ineon Sump Tester Equipment Resolution: +/-0.002" <br /> Fill Sump#87 1 Fill S=;7-8-9 Fi11 Sump#91 <br /> Sump Diameter: 44" 44" 44" <br /> Sump Depth., 68" 68" 66" <br /> Height from Tank Top to Top of N/A N/A N/A <br /> Highest Piping Penetration: <br /> Leight from Tank Top to Lowest 20" 20" 18" <br /> Electrical Penetration: <br /> Condition of sump prior to Good Good Good <br /> testing: <br /> Portion of Sump Tested 2"above piping 2"above piping 2"above piping <br /> Sump Material: Fiberglass Fiber lass Fiberglass <br /> Wait time between applying <br /> pressure/vacuum/water and 30 minutes 30 minutes 30 minutes <br /> starting test: <br /> Test Start Time: 3:43 pm 5:13 pra 5:13 prn <br /> Initial Reading(Ri): 1.8042 3.4654 1.6148 <br /> Test End Time: 3:59 pm 5:28 pm 5:28 pm <br /> Final Reading(RF): 1.6654 3.4667 1.6154 <br /> Test Duration: 16 min. 15 min. 15 min. <br /> Chane in Reading(RF-R,): -0.1388 +0.0013 +0.0006 <br /> Pass/Fail Threshold or Criteria: +/.0.002" +/.0.002" +/-0.002" <br /> Test Result: Pass ® Fail El Pass Fail El Pass Fail <br /> Is there a sensor in the sump? ® Yes ❑No ® Yes [I No ® Yes ❑No <br /> Does the sensor alarm when <br /> either product or water is ❑Yes ❑No 0 NA ❑Yes❑No ®NA ❑Yes❑No ®NA <br /> detected? <br /> Was sensor removed for testing? ❑Yes❑No ❑NA ®Yes ❑No ❑NA ®Yes 0 No [INA <br /> Was sensor properly replaced and Yes ❑No ❑NA 0 Yes ❑No LINA ®Yes❑No ❑NA <br /> verified functional after testing? <br /> Comments—(include information on repairs made prior to testing, and recommmended follow-up forfailed tests) <br /> "Sensor functionality was not confirmed.This procedure is not part of the Secondary Containment testing scope of work". <br /> 87 fill sump failed— possible electrical penetrations (2) _ <br />