My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
2448
>
2300 - Underground Storage Tank Program
>
PR0231948
>
COMPLIANCE INFO 2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/19/2022 1:14:28 PM
Creation date
4/29/2019 2:10:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0231948
PE
2361
FACILITY_ID
FA0003855
FACILITY_NAME
TESORO (SHELL) 68153
STREET_NUMBER
2448
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
05814001
CURRENT_STATUS
01
SITE_LOCATION
2448 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
340
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6. PIPING SUMP TESTING <br />Test Method Developed By: ❑ Sump Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum ® Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: Incon Sump Tester Equipment Resolution: +/- 0.002" <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />"Sensor functionality was not confirmed. This procedure is not part of the Secondary Cot n�o► of''••, <br />Replaced test boots in 91 & Diesel STP. <br />' If the entire depth of the sump is not tested, specify how much was tested. If the answer to an of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />STP Sump # 87 STP Sump # 91 ' STP Sump # Diesel <br />Sump Diameter: <br />42" 42" 42" <br />Sump Depth: <br />66" <br />66" 65" <br />Sump Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Height from Tank Top to Top of <br />18" <br />26" <br />24" <br />Hi hest Piping Penetration: <br />Height from Tank Top to Lowest <br />16" <br />18" <br />18" <br />Electrical Penetration: <br />Condition of sump prior to testing: <br />Good <br />Good <br />Good <br />Portion of Sump Tested' <br />2" above piping <br />2" above piping <br />2" above piping <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />product and water)? <br />Turbine shutdown response time <br />N/A <br />N/A <br />N/A <br />Is system programmed for fail-safe <br />❑ Yes ❑ No ® NA <br />Cl Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />shutdown?' <br />Was fail-safe verified to be <br />operational?* <br />C1 Yes ❑ No ®NA <br />❑Yes ❑ No ®NA <br />❑Yes ❑ No ®NA <br />Wait time between applying <br />pressure/vacuum/water and starting <br />30 minutes <br />30 minutes <br />30 minutes <br />test: <br />Test Start Time: <br />1:19 pm <br />1:19 pm <br />1:19 pm <br />Initial Reading (RI): <br />5.1918 <br />4.7375 <br />5.2247 <br />Test End Time: <br />1:34 pm <br />1:34 pm <br />1:34 pm <br />Final Reading (RF): <br />5.1919 <br />4.7371 <br />5.2251 <br />Test Duration: <br />15 min. <br />15 min. <br />15 min. <br />Change in Reading (RF -RI): <br />0.0001 <br />0.0004 <br />0.0004 <br />Pass/Fail Threshold or Criteria: <br />+/-0.002" <br />+/- 0.002" <br />+/-0.00211 <br />Test Result: <br />© Pass ❑ Fail <br />N1 Pass ❑ Fail <br />El Pass ❑ Fail <br />Was sensor removed for testing? <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />"Sensor functionality was not confirmed. This procedure is not part of the Secondary Cot n�o► of''••, <br />Replaced test boots in 91 & Diesel STP. <br />' If the entire depth of the sump is not tested, specify how much was tested. If the answer to an of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />