My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
2448
>
2300 - Underground Storage Tank Program
>
PR0231948
>
COMPLIANCE INFO 2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/19/2022 1:14:28 PM
Creation date
4/29/2019 2:10:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0231948
PE
2361
FACILITY_ID
FA0003855
FACILITY_NAME
TESORO (SHELL) 68153
STREET_NUMBER
2448
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
05814001
CURRENT_STATUS
01
SITE_LOCATION
2448 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
340
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7. UNDER -DISPENSER CONTAINMENT (UDC) TESTING <br />Test Method Developed By: ❑ UDC Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum ® Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: Incon Sump <br />Tester Equipment Resolution: +/- 0.002" <br />UDC Manufacturer: <br />UDC # 1/2 <br />UDC # 3/4 <br />UDC # 5/6 <br />UDC # 7/8 <br />Bravo <br />Bravo <br />Bravo <br />Bravo <br />UDC Material: <br />Steel <br />Steel <br />Steel <br />Steel <br />UDC Depth: <br />12" <br />12" <br />12" <br />12" <br />Height from UDC Bottom to Top <br />of Highest Piping Penetration: <br />Located on Bottom <br />Located on Bottom <br />Located on Bottom <br />Located on Bottom <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />Located on Bottom <br />Located on Bottom <br />Located on Bottom <br />Located on Bottom <br />Condition of UDC prior to <br />testing: <br />Good <br />Good <br />Good <br />Good <br />Portion of UDC Tested <br />2" above piping <br />2" above piping <br />2" above piping <br />2" above piping <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)?* <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />Turbine shutdown response time <br />N/A <br />N/A <br />N/A <br />N/A <br />Is system programmed for fail- <br />safe shutdown?* <br />❑ yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />[]Yes ❑ No ®NA <br />❑ Yes ❑ No ® NA <br />Was fail-safe verified to be <br />operational?* <br />❑ yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />30 minutes <br />30 minutes <br />30 minutes <br />30 minutes <br />Test Start Time: <br />3:16 pm <br />3:16 pm <br />3:37 pm <br />3:37 pm <br />Initial Reading (Rj): <br />2.6399 <br />2.7622 <br />3.3403 <br />3.3817 <br />Test End Time: <br />3:31 pm <br />3:31 pm <br />3:53 pm <br />3:53 pm <br />Final Reading (RF): <br />2.6400 <br />2.7619 <br />3.3402 <br />3.3817 <br />Test Duration: <br />15 min. <br />15 min. <br />16 min. <br />16 min. <br />Change in Reading (RF-RI):kC1 <br />0.0001 <br />0.0003 <br />0.0001 <br />0.0000 <br />Pass/Fail Threshold or Criteria:/- <br />0.002" <br />+/-0.00211 <br />+/- 0.002" <br />+/-0.002" <br />Test Result: <br />ass ❑ Fail <br />0 Pass ❑ Fail <br />© Pass ❑ Fail <br />® Pass ❑ Fail <br />Was sensor removed for testing? <br />❑ No ®NA <br />❑Yes ❑ No ®NA <br />❑Yes ❑ No ®NA <br />❑Yes ❑ No ®NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />❑ No ® NA <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No M NA ❑ Yes ❑ No ® NA <br />Comments — (include information on repairs made prior to testing, and recommended fallow -up for failed tests) <br />"Sensor functionality was not confirmed. This procedure is not part of the Secondary Containment testing scope of work". <br />FEB 0 <br />1rnlvlRONMENTAL HEAD Fr <br />DEP <br />1 If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />