My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
2448
>
2300 - Underground Storage Tank Program
>
PR0231948
>
COMPLIANCE INFO 2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/19/2022 1:14:28 PM
Creation date
4/29/2019 2:10:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0231948
PE
2361
FACILITY_ID
FA0003855
FACILITY_NAME
TESORO (SHELL) 68153
STREET_NUMBER
2448
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
05814001
CURRENT_STATUS
01
SITE_LOCATION
2448 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
340
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TEST INSTRUCTIONS <br />POPPET & FLOAT MOVEMENT <br />FOR TESTABLE MODELS ONLY <br />TOOLS NEEDED FOR TESTING: <br />1. 1/4" square drive extension or 3/8" square drive ex- <br />tension with 3/8" to 1/4" socket adapter. <br />2. Torque wrench / 1/4" or 3/8" square drive ratchet <br />wrench. <br />3. Pipe dope. <br />4. Flashlight (optional). <br />TEST STEP 1: <br />Remove spill container cover and fill cap from fill adapt- <br />er and look down into the tube and make sure no debris <br />or foreign objects are present. If debris or foreign ob- <br />jects are present take appropriate steps before proceed- <br />ing. Look down into the tube and ensure poppet is <br />completely protected by the deflection shield. See Test <br />Figure 1. If poppet is exposed and tank is not full the <br />overfill valve should be replaced. A flashlight may help <br />when inspecting the tube. <br />TEST STEP 2: <br />Unthread the socket adaptor assembly from the inlet <br />tube using a 1/4" square drive extension and wrench. <br />The extension will attach to the socket adaptor. Secure <br />all tools to ensure they don't fall into the tank or valve. <br />With the extension still attached pull on the socket <br />adaptor and cable assembly and ensure float and pop- <br />pet move /function properly. It should only require 3" <br />to 4" of movement and less than 5 lbs of force in order <br />to actuate the float and poppet. When looking down <br />into the upper tube ensure poppet is visible and moves <br />into the flow path (see Test Figure 1 & 2) when socket <br />adaptor is pulled and resets properly when socket adap- <br />tor is released. If poppet does not actuate freely take <br />appropriate steps to correct. <br />TEST STEP 3: <br />Apply pipe dope to the socket adaptor threads. Pipe <br />dope should be a non -hardening gasoline resistant pipe <br />thread seal compound. Make sure poppet and float <br />have reset properly and are not visible then install sock- <br />et adaptor and torque to 3.5 ftdbs (42 in -lbs) minimum <br />to 5.0 ft -lbs (60 in -lbs) maximum. After installing socket <br />adaptor, to ensure vapor tightness, OPW recommends <br />conducting pressure testing per CARB TP201.1 D. Some <br />areas may require pressure testing of overfill valve per <br />CARB TP201.1 D to ensure valve is vapor tight. If the <br />drop tube fails pressure testing it may be necessary to <br />check the seal at the poppet adaptor threads. Reinstall <br />fill cap and spill container cover after testing. <br />Socket <br />Open Poppet <br />Test Figure 1 <br />Op. <br />PoK <br />ptor <br />Closed Poppet <br />Pull on extension and <br />socket adaptor <br />Test Figure 2 <br />'s <br />17 <br />
The URL can be used to link to this page
Your browser does not support the video tag.