My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
2448
>
2300 - Underground Storage Tank Program
>
PR0231948
>
COMPLIANCE INFO 2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/19/2022 1:14:28 PM
Creation date
4/29/2019 2:10:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0231948
PE
2361
FACILITY_ID
FA0003855
FACILITY_NAME
TESORO (SHELL) 68153
STREET_NUMBER
2448
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
05814001
CURRENT_STATUS
01
SITE_LOCATION
2448 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
340
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.si4ov.or /c/eehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br />Facility Tesoro Shell #68153 <br />VIOLATIONS <br />Facility 2448 Keftleman Ln Lodi CA 95240 <br />Inspection May 29, 2014 <br />y <br />Name: <br />M <br />Address: <br />HSC = California Health and Safety Code: CCR = California Code of Regulations <br />Date: <br />Facility <br />Grace Keller <br />File Review <br />101 HSC 25284 <br />Title: <br />Manager <br />102 HSC 25404.5 <br />e: <br />405-1267 <br />Contact: <br />No written agreement between the person that the operating permit was issued to and the tank operator to <br />monitor the tanks stem <br />104 HSC 25292.2 <br />Current financial responsibility documents not on file with the Environmental Health Department (EHD) <br />105 CCR 2711 <br />Current Unified Program Consolidated Forms not on file with the EHD (Facility and tank form) <br />Inspection X Routine X Monitoring System <br />Type: <br />Certification Installation i I Complaint - ID# <br />Other: <br />(Authority HSC 25289) <br />108 CCR 2637 <br />Grace Keller <br />Manager <br />Consentfor Xinspection XSampling XPhotos <br />110 HSC 25291 (0 <br />Granted by: <br />Title: <br />Monitoring GarcoPiping <br />Panel: llbEMC <br />System <br />XPressurized Suction Gravity <br />Overfill <br />Prevention: <br />XMechanical Audible/visual <br />UST <br />45 <br />115 CCR 2660(k) <br />6 <br />116 HSC 25292.5 <br />Enhanced leak detection (ELD) testing not performed on a system located within 1000' of public well, or <br />failures not repaired and retested <br />- - - - - - <br />- - <br />- - - - - <br />- - - - - <br />-- - - - - - <br />-- <br />diesel <br />87 octane - <br />-91 <br />-----------Product <br />Maintenance & monitoring records not maintained 3 years, cathodic protection records for 6 % years, written <br />performance claims pertaining to release detection systems for 5 years, or records of repairs, linings, and <br />upgrades for the life of the tank. Monitoring records include: (1) date and time of all monitoring or sampling; <br />(2) monitoring equipment calibration and maintenance records, (3) results of any visual observations; (4) <br />results of sample analysis performed a lab or in the field, (5) logs of all readings of gauges or other monitoring <br />equipment, round water elevations, or other test results; 6 results of inventory readings and reconciliations <br />202 CCR 2712(i) <br />Monitoring plan, response plan, and/or operating permit and all conditions not onsite <br />203 CCR 2650 <br />Unauthorized release that: (c) did not escape secondary containment and cleaned up within eight hours (M1) <br />was not recorded, (e) escaped secondary containment, not cleaned up after eight hours, or a sudden loss of <br />product was not reported lathe EHD within 24 hours <br />Designated <br />r�Kris Bell <br />12-2-15 <br />Violations M1 -Release Detection <br />M2 -Release Prevention M3 - Both <br />Opeao <br />Date: <br />On Site Service Kris Bell <br />ICC Exp- <br />10-2-14 Manufacturer's vml 11 - 19-14, <br />Vr 3-4-16, <br />Technician: <br />Date: <br />Training: <br />Inspector Received B . Title: <br />Aris Veloso (209) 468-3453 <br />EHD 23-02 Rev 04/19/12 Page 1 UST INSPECTION REPORT <br />VIOLATIONS <br /># <br />C1 <br />C2 <br />M <br />Code Section <br />HSC = California Health and Safety Code: CCR = California Code of Regulations <br />C1 = Class 1 violation, C2 = Class 2 violation, M = Minor violation <br />File Review <br />101 HSC 25284 <br />No permit to operate <br />102 HSC 25404.5 <br />Annual operating fees not paid <br />103 HSC 25284(a)(3) <br />No written agreement between the person that the operating permit was issued to and the tank operator to <br />monitor the tanks stem <br />104 HSC 25292.2 <br />Current financial responsibility documents not on file with the Environmental Health Department (EHD) <br />105 CCR 2711 <br />Current Unified Program Consolidated Forms not on file with the EHD (Facility and tank form) <br />106 CCR 2632(b) <br />Monitoring Program (Monitoring & Response Plans) is not current or approved by the EHD <br />107 CCR 2632(d)(1)(C) <br />Plot plan/site map not submitted or fails to completely show where monitoring is performed <br />108 CCR 2637 <br />Secondary containment: (a) test not performed, (e) test report not submitted within 30 days, (f) test notification <br />not provided to the EHD at least 48 hours prior to conducting the test <br />109 CCR 2638 <br />Monitoring equipment certification: (a) not performed annually; (d) test report not submitted within 30 days, <br />(e) test notification not provided to the EHD at least 48 hours prior to conducting an installation, repair, <br />replacement, calibration, or certification <br />110 HSC 25291 (0 <br />Annual line leak detector test not performed (MI) <br />111 HSC 25284.2 <br />Annual spill containment testing not performed <br />112 CCR 2636(1)(4) <br />Annual line tightness test not performed if positive shutdown or fail safe not present (M1) <br />113 X CCR 2715(a) <br />Failed to inform the EHD of a change of designated operator within 30 days <br />114 CCR 2715(b) <br />Designated operator does not possess a current ICC CA UST System Operator certification <br />115 CCR 2660(k) <br />Repair for tank or piping not tested for tightness after completion of the repair pursuant to (M2) <br />permit conditions <br />116 HSC 25292.5 <br />Enhanced leak detection (ELD) testing not performed on a system located within 1000' of public well, or <br />failures not repaired and retested <br />117 CCR 2661 <br />Permit to repair UST system not obtained <br />118 HSC 25286(a) <br />Operational permit not amended when UST storage and/or monitoring system changed <br />119 HSC 25298(b) <br />Permit to temporarily close UST system not obtained <br />120 HSC 25298(c) <br />Permit to close UST system not obtained <br />On Site Records <br />201 CCR 2712(b) <br />Maintenance & monitoring records not maintained 3 years, cathodic protection records for 6 % years, written <br />performance claims pertaining to release detection systems for 5 years, or records of repairs, linings, and <br />upgrades for the life of the tank. Monitoring records include: (1) date and time of all monitoring or sampling; <br />(2) monitoring equipment calibration and maintenance records, (3) results of any visual observations; (4) <br />results of sample analysis performed a lab or in the field, (5) logs of all readings of gauges or other monitoring <br />equipment, round water elevations, or other test results; 6 results of inventory readings and reconciliations <br />202 CCR 2712(i) <br />Monitoring plan, response plan, and/or operating permit and all conditions not onsite <br />203 CCR 2650 <br />Unauthorized release that: (c) did not escape secondary containment and cleaned up within eight hours (M1) <br />was not recorded, (e) escaped secondary containment, not cleaned up after eight hours, or a sudden loss of <br />product was not reported lathe EHD within 24 hours <br />Inspector Received B . Title: <br />Aris Veloso (209) 468-3453 <br />EHD 23-02 Rev 04/19/12 Page 1 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.