Laserfiche WebLink
25. PIPING IMFORKATIOM J <br /> PIPING INFORMATION TANK# TANK# TANK# TANK# <br /> DISTANCE from i' /T, ���; / _ �• <br /> DISPENSER to TANK <br /> IANUFACTURER t / Smith Fiberglass <br /> SYSTEM TYPE <br /> Pressure vapor en <br /> • <br /> Double a Single a <br /> CONSTRUCTION ** <br /> ll <br /> MATERIAL *** High Density Poly Ethylene / Fiberglass <br /> LEAK DETECTION SYSTEM Veeter / Root TLS 350 <br /> 100% METHANOL COMPATIBILITY with Y E S <br /> FRP <br /> CORROSION PROTECTION High Density PoTy Et y ene i erg ass <br /> ' System Type; suction, pressure, and gravity <br /> *� Construction: single-walled, double-walled, lined-trench, etc. <br /> *** Material Type; steel-iron, stainless-steel, fiberglass, etc. <br /> 26. X_ Piping (cross-sectional diagram, including connections to tank and dispensers). <br /> Double wall piping or _ Secondary containment (Trench liner, etc.) <br /> (1) Product line (leak detector or automatic shut-off on <br /> pressurized piping). <br /> X (2) Vent and vapor recovery lines if not designed to <br /> prevent the entrance of standing fluids. (Ball float valve) <br /> (3) Manways and other single walled pipe fittings on a <br /> double-walled tank, if not designed to prevent the <br /> entrance of standing fluid. <br /> X State Water Resources Control Board "Facility (A)" and "Tank Permit (B)" application forms submitted. <br /> 28. X Plan review and operating permit fees paid. <br /> 29. X Monitoring and Response Plans submitted. <br /> 30. Proof of financial responsibility on file. <br /> 31. X what is the approximate depth to ground water: 30 ft <br /> (include source of information - borehole logs, monitoring we(L data, water <br /> studies, etc.) <br /> min Pr <br /> 32. Total number of tanks on site after installation: 2 two (12000) (6000 , 6000 split) <br /> 33. Any existing tanks to be removed or abandoned? YES C`Y NO C ) If yes, submit State Water Resources <br /> Control Board "Facility Permit (B)" application form. <br /> 34. N A Responsible party(ies) shall submit a "Letter of Commitment• prior to the <br /> installation of new tanks. (Applies to sites with documented soil and/or groundwater contamination) <br /> 35. X County/City Fire District and Building Department notified. <br /> 36. REMARKS <br /> ---------------------------------------------------------------------------------------------------------------------------- <br /> ---------------------------------------------------------------------------------------------------------------------------- <br /> ---------------------------------------------------------------------------------------------------------------------------- <br /> ---------------------------------------------------------------------------------------------------------------------------- <br /> ---------------------------------------------------------------------------------------------------------------------------- <br />