My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
8115
>
2300 - Underground Storage Tank Program
>
PR0231563
>
COMPLIANCE INFO 2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/25/2020 11:34:50 AM
Creation date
5/3/2019 2:18:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0231563
PE
2361
FACILITY_ID
FA0000110
FACILITY_NAME
J & L MARKET
STREET_NUMBER
8115
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
FRENCH CAMP
Zip
95231
APN
19317003
CURRENT_STATUS
01
SITE_LOCATION
8115 S EL DORADO ST
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
134
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> ` Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sjgov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: M�a26, <br /> J & L MARKET 8115 S EL DORADO ST FRENCH CAMP 2016 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 115 CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days. <br /> A new designated operator, Stephanie Murphy, performed the monthly inspections on 4/1/16 and 5/6/16 and <br /> notification was not provided to the EHD within 30 days of the change. Any changes shall be reported to the EHD <br /> within 30 days. Immediately log into the California Environmental Reporting System (CERS)at <br /> hftp://cers.calepa.ca.gov and upload the notification identifying all the designated operators for this facility. <br /> This is a minor violation. <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions. <br /> Maintenance and monitoring records for the last three years were not found on site. The missing records include: <br /> -2014 monitoring certification test results <br /> -2015 monitoring certification test results 00 S14- <br /> -2014 secondary containment test results <br /> -Alarm logs documenting the facility response to alarms, including 3/5/16 and 3/7/16. According to designated <br /> operator monthly inspection reports, the facility has responded to at least one alarm by removing water from a sump. <br /> -Work orders for the response to the fuel and sensor out alarms on 4/27/16. According to the designated operator <br /> monthly inspection reports,the alarm was corrected by a third party. <br /> These records shall be maintained on site for at least three years. Monitoring records include: (1)date and time of all <br /> monitoring or sampling; (2)monitoring equipment calibration and maintenance records; (3)results of any visual <br /> observations; (4) results of sample analysis performed a lab or in the field; (5)logs of all readings of gauges or other <br /> monitoring equipment, ground water elevations, or other test results; (6) results of inventory readings and <br /> reconciliations. Immediately locate and maintain all maintenance and monitoring records for the last three years on <br /> site and submit copies to the EHD. <br /> This is a repeat violation, Class-11. w c-0 now h Qv�o QP <br /> Am <br /> 207 CCR 2715 Designated operator did not inspect all required' items and/or the inspection reports not completed./enje <br /> The designated operator failed to document all the alarms from the attached alarm history on the March 2016 <br /> designated operator monthly inspection report and failed to check that they were responded to appropriately. The <br /> missing alarms include: <br /> 3/5/16- L3 (diesel STP sump)'sensor out'alarm <br /> No documentation of follow up was included with the monthly inspection for the following alarms: <br /> 4/27/16- L3 (diesel STP sump)'sensor out' and fuel alarms <br /> 3/7/16- L3 (diesel STP sump)fuel alarm <br /> 3/5/16-L3 (diesel STP sump)'sensor out'and fuel alarms <br /> During the monthly inspection, the designated operator shall review the alarm history for the previous month, check <br /> that each alarm was documented and responded to appropriately, and attach a copy of the alarm history with <br /> documentation taken in response to any alarms to the monthly report. Ensure that designated operators performing <br /> monthly inspections at this facility are including all of the required information on the reports a T�4 <br /> This is a repeat violation, Class 11. � ��^ � r� V^I rP <br /> ,V CCS V <br /> Page 4 of 6 JUN 2 4 Z015 <br />
The URL can be used to link to this page
Your browser does not support the video tag.