FLAT BACKSPLASH PANEL INST. DETAILSECURE PANELSTO WALL STUDS(HOLES AND FASTNERSBY OTHERS)SLIDEPANELBEHINDHOODFLATBACKSPLASHPANELENCLOSURE PANEL INSTALLATION DETAILFASTEN TO WALLHARDWARE BY OTHERS5/16'' BOLTSPROVIDED BYMANUFACTURERCLAMPSPROVIDED BY MANUFACTURERHOOD TOPZERO CLEARANCE TO END OF HOODNOTES:TO BE UL LISTED THERE MUST BESIDESPLASH PANELS MOUNTED THE FULLWIDTH OF THE HOOD AGAINST THECOMBUSTIBLE WALL1" INSULATIONFULL WALLEND FILLER PANELPARTIAL WALLEND FILLER PANEL1" INSULATIONVERIFICATION OF HOOD HANGING HEIGHT ABOVE FINISHED FLOOR (A.F.F.)IS REQUIRED FOR CORRECT PLACEMENT OF FIRE SYSTEM NOZZLES.HOOD HANGING HEIGHT FOR FIRE SYSTEMSRECOMMENDED HANGING HEIGHT = 80" FROMFINISHED FLOOR TO LOWER FRONT EDGE OF HOOD.OTHER HANGING HEIGHT = __________" FROMFINISHED FLOOR TO LOWER EDGE OF HOOD.TYPICALHANGERBRACKETSUPPLY PLENUM HANGER BRACKET DETAILTYPICALHANGERBRACKETON HOODS OVER 120"HOOD HANGER BRACKET DETAILNOT TO SCALEREFERENCE SCALED DRAWING FOR ACTUAL LOCATIONSTYPICAL HOOD HANGING METHODTHREADEDROD (1/2")WASHERHANGERBRACKET1/2" NUTSHIPPED LOOSE DUCT COLLAR INST. DETAILEXHAUST COLLARCUT-OUT AREAEXHAUST COLLAR NOTES: EXHAUST DUCT CONNECTION TO BE LOCATED WITHIN 48" FROM CENTER OF HOOD LENGTH TO CENTER OF DUCT CONNECTION. UL LISTED HOOD ASSEMBLY TO BE USED ONLY WITH MANUFACTURER, LABELED SUB-ASSEMBLY, FOR EXHAUST HOOD WITHOUT EXHAUST DAMPER PART NO. DC. EXHAUST DUCT CONNECTION IS TO BE A CONTINUOUS LIQUID TIGHT WELD TO HOOD.SUPPLY PLENUM INFORMATIONPOS.HOODNO.MARKTYPELCOLLARSWLDIA.CFMS.P.INSULATEDDAMPER(S)VEL.LED LIGHT(S)WHSIZE (IN.)TYPEMOUNTINGQTYQTYSUPPLIEDTOTALCFM1KH-1 ITEM 13FRONTMUA10 20 707 0.16 509FACTORY3133NONO NO14 10ASP2120MODELLENGTH WIDTH HEIGHTHOOD DIMENSIONS (IN.)MARKWIDTH LENGTHDIA. CFM S.P.COLLAR(S)EXHAUSTHOOD INFORMATIONHOODNO.COOKINGLOAD /DUTYRATINGHOODCONSTR.MUACFMACCFMTOTALWEIGHTLBS.SECTIONLOCATIONTOTALCFMSUPPLY10 250.4642650112048SINGLE24XBEW-120-S KH-1 ITEM 1326502120350HEAVY430 SSWHEREEXPOSEDLIGHTING DETAILSQTYLGREASE FILTRATION DETAILSQTYHLOCATIONUTILITY CABINET(S)CONTROLSHOOD INFORMATIONMARKFIXTURE TYPE BULB / LAMP INFOFOOTCANDLESTYPE / MODELMATERIALSIZE (IN.)HOODNO.FIRE SYSTEMMODELTYPE SIZEINTERFACE41.35620020161INCANDESCENT (GLOBE)100W A19 (BULBS NOT INCL.)BAFFLESTAINLESS STEELKH-1 ITEM 13LEFT AMEREX KP5.53HOOD OPTIONS UL 710 LISTED W/ OUT EXHAUST FIRE DAMPER - UL #R25625 BACK INTEGRAL AIR SPACE - 3 IN WIDE RIGHT NON-INTEGRAL AIR SPACE - 1 IN THICK - ZERO CLEARANCE 16 IN HIGH CEILING ENCLOSURES - FRONT LEFT RIGHT - FIELD INSTALLED SHIPPED LOOSE EXHAUST COLLAR(S) BACKSPLASH 80.00 IN HIGH 133.00 IN LONG RIGHT SIDESPLASH 80.00 IN HIGH 38.00 IN LONG PERFORMANCE ENHANCING LIP (PEL) TECHNOLOGY STANDING SEAM CONSTRUCTION FOR SUPERIOR STRENGTH1 FP119821 FP119822 FP141781 FP119822 FP141781 FP119822 FP13729RIGHT END FLATBACKSPLASH PANELGas Char-BroilerFuel Type: Gas36" L X 30" W X 36" HRange - 4 or more burnersFuel Type: Gas36" L X 30" W X 36" HGriddleFuel Type: Gas24" L X 30" W X 36" HFryer - Full Vat with DripboardFuel Type: Gas16" L X 30" W X 36" HCheese MelterFuel Type: Gas36" L X 18" W X 18" H1 FP164161 FP16416MARK: KH-1 Item 13 - SECTION 1ELEVATION VIEWKH-1 ITEM 13 <br />KABOBI GO - LODIACCUREX - NORTHERN CA <br />FRED KORTH <br />FRED.KORTH@ACCUREX.COM <br />(415)806-9044 <br />PROJECT <br />MARK <br />5/4/2018REAR INTEGRAL AIR SPACEMARK: KH-1 Item 13 - SECTION 1PLAN VIEW40 IN. OCTEMPERATURE SENSORSFIELD WIRING TO CONTROLS REQUIRED1 FP11982FIRE SYSTEM MARK: FSS - Item 5AGENTTANKAMEREXMECHANICALRELEASEMODULEAGENTTANKCHROME APPLIANCE DROPSPERFORATEDAIR CURTAINMARK: KH-1 Item 13 REMOVABLE GREASE CUP W/CONCEALED GREASE TROUGHSECTION VIEWUL LISTEDSTANDARD BAFFLE FILTERSINTEGRAL AIRSPACEUL LISTED LIGHT FIXTURETEMPERATURESENSORS133.0SUPPLY PLENUM LENGTH3.63.62.62.6HOOD LENGTH3.63.64.02.63.0AIRSPACEHOOD LENGTH8.08.016.06.01.01.055.029.022.244.344.322.27.020.010.020.010.020.010.025.010.0120.01.0AIR SPACE12.03.048.014.062.010.04.080.0ABOVEFINISHEDFLOOR24.016.0120.0133.0 in. LENGTHBACKSPLASH PANELANSUL SYSTEM DETAILS <br />HOOD CALCULATION SHEET <br />5453KABOBI GO <br />Kitchen Design ConsultantsLODI, CA 95242 <br />DESIGNERS AND SUPPLIERS OF <br />EQUIPMENT AND INTERIORS FOR <br />HOTELS, RESTAURANTS AND <br />INSTITUTIONSBEASt <br />AYCONSTRUCTIONNOT FORPRELIMINARY PLAN-NOT FOR CONSTRUCTION14800 STAR STREET11FS-8