S1S1HFAN SWITCH 1FAN SWITCHSHIPPED LOOSE208/3 15 AMPSMARK: KEF-11.5 HPTYPICALEXHAUSTFANOL1T1L1T1T2L2T2T3L3T3L1L2L3ST1115/1 15 AMPSMARK: MUA-1 Champion Cooler0.5 HPL1L2TYPICALSUPPLY FANOL2 ST2T1L1T1T2L2T2T3L3T3Electrical - Field Wiring SchematicH1N1POWER WIRING FOR XFCC CONTROL SYSTEMBUILDING BREAKER PANELCONTROLNON-SHUNTEDSHUNT TRIP COIL120V OUTPUT DURINGFIRECONTROL WIRING FOR XFCC CONTROL SYSTEMT1-AT1-B120/1 15 AMPSPanel Mark:INPUTOUTPUTINPUTOUTPUTSHUNT TRIP BREAKER IN BUILDINGPANEL (PROVIDED BY OTHERS)1. All wiring to be done by certified and qualified persons andmust be wired to all local & national codes.2. Exhaust and supply fan(s) shown as typical forrepresentation of the fan. For exhaust or supply fan detailsee fan submittals.3. Exhaust and/or supply fans may be shown more than oncefor purpose of separating power versus control wiring.Capture TankNOTE: ALL SENSORS TOBE WIREDINDEPENDENTLYDuct CollarShippedLoose for FieldInstallation4. Power wiring is the responsibility of the electrician. Control wiringis the responsibility of controls contractor. If there is no controlscontractor, both power and control wiring is the responsibility of theelectrician.5. All ground wiring not shown on above diagram for clarity.6. For further instructions please see the XFCC Installation andOperations Manual that was shipped with panel, or contactACCUREX's Kitchen Ventilation team at 1-800-371-6858Possible Sensor Locations:Note(s):HOOD TEMPERATURESENSOR 1USE 18 AWG, STRANDEDPLENUM RATED WIRELocation:Ship LooseControlsKitchen Fan Control Center (XFCC)Kabobi Go - LodiUSE 18 AWG,SHIELDED WIREC1NO1FIRE SYSTEM MICROSWITCHNC1FIRE SYSTEMMICROSWITCHCOMNONCC3NO3NC3C4NO4NC4SPARE, DRY CONTACTSON/OFF WITH FIRECOMMONNORMALLY OPENNORMALLY CLOSEDCOMMONNORMALLY OPENNORMALLY CLOSEDSPARE, DRY CONTACTSON/OFF WITH FIRE*** DRY CONTACTS ARERATED UP TO 250VACAND 8 AMPSSTNSTHNOTE: ALL SENSORS TOBE WIREDINDEPENDENTLYFIELD WIRINGFACTORY WIRINGNOTE: REMOVE JUMPER BETWEEN C1,NC1 ONCE MICROSWITCH IS CONNECTEDWiring Diagram Code:DOC NUMBER: ####REV: ####LIGHT SWITCH 1LIGHT SWITCHSHIPPED LOOSEBLACKBLACKB2H2H2N2120/1 15 AMPSHOOD LIGHTS 1INPUT POWERHOOD LIGHTS 1120V OUTPUT TOLIGHTSB2W2TYPICAL HOODWIRE TO ALL HOOD LIGHTS TOOPERATE WITH LIGHT CIRCUIT 1 (1400WMAX)KH-1 Item 13 Section 1CAPTURE TANK1HOOD MARKQTYLOCATIONSENSORCONTROL PANELInstallation Location:Ship LooseVoltGas Off w/FansQty. Temp. Switches (0-1)Remote SwitchesTempering SWTERMINAL BLOCKS = 8 LB.INGROUNDING BLOCKS = 8 LB.INSTBAFWiring Diagram Code:DECPBSVSTSLTGFSEFSFOL CRRD/RDC2NO2NC2BK/YWBR/BKCNCNOAudible AlarmGas ResetPower for Gas SolenoidPower for Shunt TripHeat SwitchCool SwitchAD SwitchOne Switch for L & FQty. Light Switches (0-3)Qty. Fan Switches (0-3)Hood Mark(s):Fan MarkMotorHPPanel Mark:OR - orangeYW - yellowWH - whiteRD - redPR - purpleFIELD WIRINGBK - blackBL - blueUNLESS SPECIFIEDBR - brownUSE MINIMUM60° Copper WireFACTORY WIRINGAnsul / AmerexRD/RDBK/YWBR/BKFS2EF Failure LightOff Delay RelaySF Failure LightAux. Supply ContactFan Failure Light (Appl.)Tie in WWCPExhaust in FireLights Out in FireDPDT Relay w/SFDPDT Relay w/EFFire Relay (#1)Extra Fire Relay (#3)Extra Fire Relay (#2)MUA InterfaceWirePH FLA Breaker110XXXXXXShunt Trip BreakerAir Flow SwitchDamperEvap CoolerPushButtonGas SolenoidStarterSwitchLightGroundFire Switch Exhaust FanSupply FanOverLoadContactorRelayNOTES:DRAWING SHOWN DE-ENERGIZED AT L1 (TERM. #H1),W/ FIRE SYSTEM ARMED (NON-FIRE MODE). (NORMALOPERATION, R1 & R2 ARE ENERGIZED) IF WALLMOUNTED PREWIRE, OR FIELD INSTALLED FIRESYSTEM, THE FIRE SYSTEM MICROSWITCHES MUSTBE FIELD WIRED.Digitial Temperature Interlock1Mounted Sensors - Factory0Mounted Sensors - Field TCTSTemperature ControllerTemperature SensorTORQUE:FIELD WIRING:LABEL DESCRIPTIONWIRE COLORALL WIRING 90°C 14 GA.ControlsKitchen Fan Control Center (XFCC)Electrical Prewire PackageKabobi Go - LodiThese drawings shall not be removed from this equipment.For additional information call ACCUREX at 1-800-371-6858SYSTEM DRAWING NOTELISTED43BMCOMMERCIAL APPLIANCE OUTLET CENTERELECTRICAL RATINGS: 120V, 1PHASE, 60HZ, 15AFILE #E313951Spare Fire Switch Contact (dry contacts for building alarm)Serial Number:Model:XFCCDOC NUMBER: ####REV: ####TEMPERATURE INTERLOCK CALIBRATION1. PRESS SET BUTTON. 'St1' WILL APPEAR.2. PRESS UP OR DOWN BUTTON TO NAVIGATE TO SET POINT THAT YOU WISHTO ADJUST ('St1', 'St2', OR 'St3').3. PRESS SET BUTTON TO VIEW CURRENT SET POINT. PRESS UP OR DOWNBUTTON TO ADJUST AND PRESS SET BUTTON TO STORE VALUE.4. PRESS SET + DOWN BUTTONS TOGETHER TO EXIT OR WAIT 1 MINUTE.5. CHECK SYSTEM OPERATION BEFORE MAKING ADDITIONAL ADJUSTMENTS.LIGHT INPUT: 120VAC,15AMPS FROM BREAKER1200W max.H2S2L1LTLTN2NSwitches Mounting - Ship Loose for Remote MountingBK14R1011B2HW2WHF1-E KEF-1 1.5 208 3 6.6 14 ga 15 ampF2-SMUA-1 Champion Cooler0.5 115 1 9.8 14 ga 15 ampclosed w/power at H1/N1 & fire system armedopen w/power at H1/N1 & fire system armed(can be used for shunt trip, alarms, etc.)Spare Relay Contactsclosed on fire or no poweropen on fire or no power2224ABBANC3BRC3NO3RDBKNO4NC4ABR121C432BR3134RDBKR1(activated by FS1)208/3 PHASE3 WIREFROM BREAKERL3L2INPUT POWERL1OL1 ST1T1L1T1T2L2T2T3L3T3GExhFAN 1115/1 PHASE2 WIREFROM BREAKERL2INPUT POWERL1NOL2 ST2T1L1T1T2L2T2T3L3T3GSupplyFAN 2CONTROL INPUT: 120VAC, 15AMPS FROM BREAKERH1L1N1NGT1-BT1-ATS1TC1RD21311124WHRDS1FIELD MOUNTED SWITCHFIELD WIRING TO SWITCH REQUIREDS1ORS1HS1ORS1H2423TC1RD1112R196A1ORA2ST1WH95OL196A1YWA2ST2WH95OL21411R1YWORD3D1D2CNOBK(YW)RDRD(RD)C1NCFS1BR(BK)NO1NC1BRA1R1A2WHA1A2R10STHSTB1STNWHBKCONTROLS <br />KABOBI GO - LODIACCUREX - NORTHERN CA <br />FRED KORTH <br />FRED.KORTH@ACCUREX.COM <br />(415)806-9044 <br />PROJECT <br />MARK <br />5/4/2018 MARKCONTROL INFORMATIONFANS CONTROLLEDTYPEHPVOLTPHASEMARKMODELLOCATIONUSER INTERFACELOCATIONELECTRICAL CONTROL PACKAGETYPESWITCHESSHIP LOOSEXFCCSHIP LOOSECONTROLSEXHAUST 208 3KEF-11 1/2SUPPLY 115 1MUA-1 CHAMPION COOLER1/2CONTROL FEATURESCONTROL PANEL ENCLOSURE - 16 GA 300 SERIES STAINLESS STEEL ENCLOSURE (NEMA-1) - DIMENSIONS 12 X 20 X 6STARTERS PROVIDED IN CONTROL PANEL - QTY 22 POSITION LIGHT SWITCH - QTY 12 POSITION FAN SWITCH - QTY 1 -FACTORY MOUNTED EXHAUST TEMPERATURE SENSORS - QTY 1TURN ON EXHAUST IN FIRELIGHTS OUT IN FIREPOWER FOR SHUNT TRIPTHERMAL OVERLOADS IN CABINET20.06.012.0ANSUL SYSTEM DETAILS <br />HOOD CALCULATION SHEET <br />5453KABOBI GO <br />Kitchen Design ConsultantsLODI, CA 95242 <br />DESIGNERS AND SUPPLIERS OF <br />EQUIPMENT AND INTERIORS FOR <br />HOTELS, RESTAURANTS AND <br />INSTITUTIONSBEASt <br />AYCONSTRUCTIONNOT FORPRELIMINARY PLAN-NOT FOR CONSTRUCTION14800 STAR STREET11FS-9