Laserfiche WebLink
NOTES:1.2.NOTES:NOT TO SCALE2131. MRM (MECHANICAL RELEASE MODULE)2. NITROGEN ACTUATION CYLINDER3. MICROSWITCHWIRING DIAGRAMSW/ DPDT MICRO SWITCHDPDT SWITCHES PROVIDED BY MANUFACTURER MAYBE WIRED PER TYPICAL EXAMPLES SHOWN, VERIFYWITH LOCAL CODES AND EQUIPMENT SUPPLIED ASTHE CONNECTION NEEDED FOR YOUR INSTALLATION.CONTROL PANEL3. GAS VALVES: "UL LISTED ELECTRICALLY-OPERATEDSAFETY VALVE FOR NATURAL, OR LP GAS AS NEEDED OFAPPROPRIATE PRESSURE AND TEMPERATURE RATING,110V/60 HZ" OR AMEREX GAS VALVES, PART NUMBERS12790, 12791, 12792, 12793, 12794, 12870, 12871, 12872,12873, 12874, 12875 AND 12876.WET CHEMICAL FIRE PROTECTION SYSTEM TO BE AMEREX KP, DESIGNED INCOMPLIANCE WITH UL 300 REQUIREMENTS.-VERIFICATION OF ALL COOKING EQUIPMENT MAKE, MODEL AND LOCATIONREQUIRED FOR ALL FIRE PROTECTION SYSTEMS.-ALL FIRE SYSTEM PIPING IS STANDARDLY TO THE RIGHT END OF THE HOODUNLESS A WALL IS LOCATED ON THE RIGHT END.-AMEREX MRM/PRM TO BE LOCATED WITHIN 60" OF HOOD.THE BASIC FIRE SYSTEM WILL INCLUDE THE FOLLOWING:-GAS SHUT-OFF VALVE, IF REQUIRED, TO BE SUPPLIED BY MANUFACTURER (UP TO2" DIAMETER AS STANDARD), AND INSTALLED BY A LICENSED PLUMBER.-MICRO SWITCH TO BE SUPPLIED BY MANUFACTURER FOR CONNECTION TO, BUTNOT LIMITED TO, BUILDING ALARM SYSTEM(S), EXHAUST AND SUPPLY FANS ANDELECTRICAL POWER SHUT DOWN. FIELD WIRING AND CONNECTIONS TO BEPERFORMED BY A LICENSED ELECTRICIAN.-THREE TRIPS TO THE JOBSITE-ANY STATE OR LOCAL INSTALLATION PERMITS.THE BASIC FIRE SYSTEM DOES NOT INCLUDE THE FOLLOWING:-FULL DUMP TEST OTHER THAN WHT IS SPECIFIED PER THE INSTALLATIONMANUAL,OR TO SATISFY A STATE OR LOCAL CODE.-MORE THEN THREE TRIPS TO THE JOBSITE OR SPECIAL TRANSPORTATION, OROVERNIGHT LODGING REQUIREMENTS IN REMOTE AREAS. NORMAL TRAVELDISTANCE IS FIRST 50 MI. (80.5 KM) FROM OFFICE.-SPECIAL CLASSES OR ADDITIONAL LABOR FOR ACCESS TO SECURITY SENSITIVEAREAS.-INSTALLATION OF GAS SHUT-OFF VALVE.-SPECIAL DRAWINGS REQUIRED TO SATISFY STATE OR LOCAL CODE.-UNION LABOR, GOVERNMENT LABOR, OR PREVAILING WAGES REQUIRED FOR FINALFIELD HOOK-UP.-ANY AND ALL ELECTRICAL COMPONENTS/CONNECTIONS REQUIRED TO SHUT DOWNFANS, SHUT OFF DEVICE FOR ELECTRIC COOKING EQUIPMENT (SHUNT TRIPBREAKER), OR ACTIVATE AN ALARM SYSTEM, ETC.-ANY DISMANTLING OR REASSEMBLY REQUIRED TO GAIN ACCESS TO THE FIRESUPPRESSION PIPING LOCATED ON THE TOP OF THE HOOD.-PLAN EXAMINATION FEES, PE OR FPS APPROVAL STAMP.-ROUGH-IN CONDUIT FOR REMOTE PULL STATION OR GAS VALVE (FOR FLUSHMOUNTED PULL STATION).-INSTALLATION OF MORE THAN (1) REMOTE PULL STATIONS OR DISTANCESGREATER THAN 20 FT (6.1M.)-PARTS OR LABOR REQUIRED TO CORRECT PIPING DUE TO COOKING EQUIPMENTCHANGES OR DEVIATION FROM PLANS. OR ANY CHARGES FOR MISSING ORADDITIONAL PARTS OTHER THEN THOSE INDICATED ON THE FIRE SUPPRESSIONDETAIL.DENOTES FIELD INSTALLATION.DENOTES FACTORY INSTALLATION.NCNO}NCVOLTAGE FREEBUILDING ALARM(S)CONTACTS FORINPUTNOMETHOD OF WIRING, IF PROHIBITED BY LOCAL CODES.DO NOT SHUT DOWN EXHAUST FANS WITH THISNCNOFAN(S)N}INPUT120 VAC ~POWER TO FANSTARTERMANUAL SWITCHCONNECTION TO BUILDINGS ALARMCONNECTION TO FAN SHUT DOWNSHUNT TRIP BREAKERPOWER TOCOOKING EQUIPMENTELECTRIC GAS VALVE - IF RESET RELAY IS USEDSEE OPTION A OR B AT RIGHT, MECHANICAL GASSHUT OFF VALVE DOES NOT REQUIREELECTRICAL CONNECTION.CONNECTION TO COOKINGEQUIPMENT SHUT DOWNN}INPUT120 VAC 11.8105AMEREX KP (WET CHEMICAL) FIRE PROTECTION SYSTEM - MODEL FSSKCONTINUOUS FUSIBLE LINKAMEREX KPWET CHEMICAL13 UTILIZED16 AVAILABLECABINET – LEFT END OF KH-1 ITEM13FSS - ITEM 5MODELMARKFIRE SYSTEM INFORMATIONLOCATIONFLOW POINTSSUPPLYLINEDETECTIONMARK(S) PROTECTED BY FIRE SYSTEMHOODS PCUKH-1 ITEM 13 SECTION 1FIRE SYSTEM OPTIONS AND ACCESSORIESFULL INSTALLATION (INCLUDES PRE-PIPED HOOD(S) WITH DETECTION AND FACTORY COORDINATED INSTALL)CHROME SLEEVES FOR FACTORY PROVIDED APPLIANCES DROPS - INCLUDEDMETAL BLOW-OFF CAPS - INCLUDEDGAS VALVE - INCLUDED - MECHANICAL SHUTOFF VALVE, 2.00" (AMEREX) - PART# AMEREXMECHSHUTOFFVALVE200HOOD SUPPRESSION AGENT - INCLUDED - 5.5 GAL. - [(2) 2.75 TANK(S)]REMOTE PULL STATION - STANDARD - INSTALLATION AT SINGLE POINT OF EGRESSUL/cUL 762 Listed - "Power Ventilators for Rest. Exh. Appliances"Switch, NEMA-1, Toggle, Shipped with UnitRoof Curb-Galv., GPFV-30-G20, Under Sized 1 in. TotalHinged Base (Attached)High Temp Curb Seal Rated for Continuous Duty at 2000 F (Attached)Grease Trap (PN 475538)Heat Baffle (Attached)Bearings with Grease Fittings, L10 life of 100,000 hrs (L50 avg. life 500,000 hrs)MODELOPERATINGPOWER (HP)V/C/PENCLOSUREVOLUME(CFM)FANRPMQTYBelt Drive Upblast Centrifugal Roof Exhaust FanMOTORRPMWINDINGSNEC FLA*MOTOR INFORMATIONSIZE (HP)WEIGHT(LB.)MARKTOTAL EXTERNAL SP(IN WG)MARK INFORMATIONFAN INFORMATIONXRUB-180HP-151.17208/60/3OP2,6501,36211725 1 6.61.5166KEF-11.5KEF-1 : SELECTED OPTIONS AND ACCESSORIES*NEC FLA - Based on tables 150 or 148 of National Electrical Code 2002. Actual motor FLA may vary, for sizing thermal overload, consult factory.RECOMMENDED EXHAUST DUCT SIZESTANDARDFIRE-WRAPPED18 SQ10 SQDUCT TYPE SIZESUGGESTED ROOF OPENINGOVERALL HEIGHT MAY BE GREATER DEPENDING ON MOTOR.DUCT DIMENSIONS ARE LARGEST POSSIBLE DUCT TO FIT THROUGH CURB.CONSULT SYSTEM DESIGN ENGINEER FOR RECOMMENDED DUCT SIZE.30.00 SQ3.4421.0028.63Ø 35.3848.63(20.00)30.00 SQØ 35.3848.63(20.00)SeeTable20.50SQ39.039.020.029.029.0KH-1 ITEM 13 <br />KABOBI GO - LODIACCUREX - NORTHERN CA <br />FRED KORTH <br />FRED.KORTH@ACCUREX.COM <br />(415)806-9044 <br />PROJECT <br />MARK <br />5/4/2018 <br />ANSUL SYSTEM DETAILS <br />HOOD CALCULATION SHEET <br />5453KABOBI GO <br />Kitchen Design ConsultantsLODI, CA 95242 <br />DESIGNERS AND SUPPLIERS OF <br />EQUIPMENT AND INTERIORS FOR <br />HOTELS, RESTAURANTS AND <br />INSTITUTIONSBEASt <br />AYCONSTRUCTIONNOT FORPRELIMINARY PLAN-NOT FOR CONSTRUCTION14800 STAR STREET11FS-10