COMPLIANCE INFO 2010 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MANTHEY
>
3408
>
2300 - Underground Storage Tank Program
>
PR0517521
>
COMPLIANCE INFO 2010 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2019 3:39:19 PM
Creation date
5/7/2019 10:21:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2018
RECORD_ID
PR0517521
PE
2361
FACILITY_ID
FA0013484
FACILITY_NAME
FOOD 4 LESS FUEL CENTER*
STREET_NUMBER
3408
STREET_NAME
MANTHEY
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
16422011
CURRENT_STATUS
01
SITE_LOCATION
3408 MANTHEY RD
P_LOCATION
01
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
383
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7AN-31-2013 09:35 Service Station Systems 408 938 8888 P.09 <br /> 9. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With rill Riser Containment Sumps ❑ <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed By: ❑Sump Manufacturer R Industry Standard C)Professional Engineer <br /> [)Other(Specify) <br /> Test Method Used: ❑Pressure ❑Vacuum R Hydrostatic <br /> C1 Other(Spec r#) <br /> Test Equipment Used: Incon Sump Tester EgUipment Resolution: +/-0,002" <br /> w" Fill Sump#87 Fill Sump#91 <br /> Sum Diameter: 42" 42" <br /> Sum2 Depth: 64" 64" <br /> Height from Tank Top to Top of 181. 19" <br /> Highest Piping Penetration: <br /> Height from"Tank Top to Lowest 301' 32„ <br /> Electrical Penetration: <br /> Condition of sump prior to Good Good <br /> testing: <br /> Portion of Sump Tested 2"above piping 2"alcove pipingi <br /> Sump Material: Fiber lass Fiberglass <br /> Wait time between applying <br /> pressure/vacuum/water and 30 minutes 30 minutes <br /> ,starting test: <br /> Test Start Time: 8:18 am 8:18 am <br /> Initial Reading(R,): 3.1051 4.5985 <br /> 'T'est End Time: 8:33 am 8:33 am <br /> Final Reading(Rr); 3.1051 4.5984 <br /> Test Duration: 15 nun. 15 min.- <br /> Change <br /> in.Chan a in Reading(RF-Rj): None 0.0001 <br /> Pass/Fail Threshold or Criteria: +/-0.002" +/-0.002" <br /> Test Result: O Pass Fail M Pass Fail <br /> Is there a sensor in the sump? ®Yes 0 No R Yes ❑No <br /> Does the sensor alarm when <br /> either product or water is ❑ Yes C)No R NA ❑Yes ❑No R NA <br /> detected? <br /> Was sensor removed for testing?_ R Yes❑No❑NA ®Yes❑No ❑NA <br /> Was sensor properly replaced and ®Yes ❑leF_1a NA ®Yes ❑ No C1 NA <br /> verified functional after testing? T <br /> Comments— (include information on repairs made prior to testing, and recommended.follnw-u for failed tests) <br /> Sensor functionality was not confirmed.This procedure is not part of the Secondary Containment testing scope of work <br /> TOTAL P.09 <br />