Laserfiche WebLink
MAR-12-2012 14: 12 Service Station Systems 408 938 8888 P.04 <br /> Monitoring System Certification- Page 2 of 3 <br /> Site Address: 3408 Manthey Road Date of Tcsting/Servicin— 2/13/12 <br /> D. Results of Testing/Servicing <br /> Software Version Installed. 327.04 <br /> Com lete the following checklist: <br /> 0 Yes ❑ No* Is the audible alarm o)erational? <br /> Z Yes ❑ No* Is the visual alarm operational? <br /> 9 Yes ❑ No* Were all sensors visually inspected, functionally tested,and confirmed o erational? <br /> 0 Yes 0 No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> riot interfere with their proper operation? <br /> ® Yes ❑ No* If alarms are relayed to a remote monitoring station, is all communications equipment(e.g. modem) <br /> ❑ N/A operational'? <br /> 3 Yes 0 No* For pressurized piping systems,does the turbine automatically shut down if the piping secondary containment <br /> Q N/A monitoring system detects a leak, fails to operate,or is electrically disconnected' If yes: which sensors initiate <br /> positive shut-down? (Check all that apply) 2 Sump/Trench Sensors; ® Dispenser Containment Sensors. <br /> Did you confirm posi0ve shut-down due to leaks and sensor failure/disconnection? 2 Yes © No <br /> ® Ye, ❑ No* For tank systerns that utilize the monitoring;system as the primary tank overfill warning device(i-c.no <br /> ❑ N/A mechanical overfill prevention valve is installed).is the overfill warning alarm visible and audible at the tank <br /> fillpoint(s)and o Gratin xo erly? If so,at what percent of tank caEacity does the alarm tri grer? 90 % <br /> ® Yes* ❑ No Was any monitoring equipment replaced? If yes, identify specific sensors,probes,or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section h,below. <br /> Is Yes* d No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> ❑ Product;9 Water. li'yes,describe causes in Section E,below. <br /> ® Yes p No* Was monitorin system set-up rcvicwcd to ensure proper settings? (Attachset-up reports, if a� Ircahle. <br /> ® Yes ❑ No* Is all monitoring equipment operational per manufacturer's specifications? <br /> " In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: Removed small amount of liquid from 87 &91 STP Sumps. <br /> Replaced Overfill Alarm -tested and passed. <br />