Laserfiche WebLink
.r <br /> CONDITIONS FOR PERMIT N-8826-1-0 �I n 1 I�PR( <br /> :g4AE: <br /> Page 1 of 2 <br /> UUU`"JJJ 1' 01/31/2018 <br /> LEGAL OWNER OR OPERATOR: MR STEPHEN G MUI66 R <br /> MAILING ADDRESS: P O BOX II L n ME) jWOODBRIDGE, CA 9 8 t�5�1LI1�U( <br /> LOCATION: 521 NORTH CHEROKEE LANE <br /> LODI, CA <br /> INSPECT PROGRAM PARTICIPANT: NO <br /> EQUIPMENT DESCRIPTION: <br /> SOIL AND GROUNDWATER REMEDIATION PROJECT SERVED BY A 12 KVA SOLLECO INSTRUMENTS MODEL 150- <br /> 250 CFM ECAT ELECTRICALLY HEATED CATALYTIC OXIDIZER (PHASE 1) OR FOUR US FILTER 200 LB ACTIVATED <br /> CARBON CANISTERS CONNECTED IN SERIES (PHASE 2). <br /> CONDITIONS <br /> 1. {1420} The soil remediation system shall be maintained in proper operating condition at all times. [District Rule 22011 <br /> 2. {15} No air contaminant shall be discharged into the atmosphere for a period or periods aggregating more than three <br /> minutes in any one hour which is as dark as,or darker than,Ringelmann 1 or 20%opacity. [District Rule 4101] <br /> 3. {98] No air contaminant shall be released into the atmosphere which causes a public nuisance.'[District Rule 4102] <br /> 4. {14) Particulate matter emissions shall not exceed 0.1 grains/dscf in concentration. [District Rule 4201] <br /> 5. {1423} Either the VOC control efficiency shall not be less than 95%, or the total VOC emission rate shall not exceed 2 <br /> pounds in any one day. [District Rule 2201] <br /> 6. The total VOC emissions from the soil remediation system when served by the catalytic oxidizer shall not exceed 11.9 <br /> pounds in any one day. [District Rule 22011 <br /> 7. The total VOC emissions from the soil remediation system when served by carbon canisters shall not exceed 1.0 <br /> pounds in any one day. [District Rule 2201] <br /> 8. The permittee shall notify the District prior to the catalytic oxidizer serving the remediation system is taken off line <br /> and the carbon canisters are installed. [District Rule 2201] <br /> 9. {1464} The minimum operating temperature for the combustion chamber of the catalytic oxidizer shall be maintained <br /> at or above 600 degrees F. [District Rule 2201] <br /> 10. (2861) The catalytic oxidizer shall be equipped with an operational temperature gauge to indicate the temperature of <br /> the combustion chamber. A continuously recording device shall be utilized to indicate the combustion chamber <br /> temperature during operation. [District Rule 220 1] <br /> 11. {1470] The soil remediation system shall not be operated unless the combustion chamber is at or above minimum <br /> operating temperature. The system shall automatically terminate operation if the temperature drops below the <br /> minimum operating temperature. [District Rule 220 11 <br /> 12. {1412} A minimum of two carbon canisters which are connected in series shall be utilized. [District Rule 22011 <br /> 13. {1413] Sampling ports adequate for extraction of grab samples, measurement of gas flow rate,and use of an FID,PID, <br /> or other District-approved VOC detection device shall be provided for both the influent and the effluent gas streams. <br /> [District Rule 108 1] <br /> 14. (403) Ongoing compliance with VOC emission rate and control efficiency requirements shall be demonstrated by <br /> sampling both the influent and the effluent gas streams with an FID,PID,or other District-approved VOC detection <br /> device. [District Rule 108 11 <br /> 15. Sampling to demonstrate ongoing compliance when the remediation system is served by the catalytic oxidizer shall be <br /> performed at least once per month. [District Rule 1081] <br /> 16. Sampling to demonstrate ongoing compliance when the remediation system is served by the carbon canisters shall be <br /> performed at least once per week. [District Rule 1081] <br /> N$9361A Jan la'lB15]SaPM—BRV VIES <br />