My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2002 - 2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MANTHEY
>
3408
>
2300 - Underground Storage Tank Program
>
PR0517521
>
COMPLIANCE INFO 2002 - 2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2019 3:00:07 PM
Creation date
5/8/2019 1:59:52 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002 - 2006
RECORD_ID
PR0517521
PE
2361
FACILITY_ID
FA0013484
FACILITY_NAME
FOOD 4 LESS FUEL CENTER*
STREET_NUMBER
3408
STREET_NAME
MANTHEY
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
16422011
CURRENT_STATUS
01
SITE_LOCATION
3408 MANTHEY RD
P_LOCATION
01
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
284
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-� The March 22, 2006 secondary containment test report for the Manthey Road facility <br /> was not received by this office until May 22, 2006. <br /> Title 23, CCR 2638 (a) Annual monitoring certification. All monitoring equipment used to <br /> satisfy the requirements of this article shall be installed, calibrated, operated and maintained in <br /> accordance with manufacturer's instructions, and certified every 12 months for operability, <br /> proper operating condition, and proper calibration. Written records shall be maintained as <br /> required in section 2712. <br /> 4 The Airport Way facility was approximately one month late for the annual monitoring <br /> certification. Testing was due by May 2005 and was not performed until June 6, 2005. <br /> 4 The Cherokee Lane facility was approximately five months late for the annual <br /> monitoring certification. Testing was due by September 2005 and was not performed until <br /> February 21, 2006. <br /> 4 The Manthey Road facility was approximately one month late for the annual monitoring <br /> certification. Testing was due by February 2006 and was not performed until March 2006. <br /> Title 23, CCR 2638 (a) Annual line leak detector test. All monitoring equipment used to <br /> satisfy the requirements of this article shall be installed, calibrated, operated and maintained in <br /> accordance with manufacturer's instructions, and certified every 12 months for operability, <br /> proper operating condition, and proper calibration. Written records shall be maintained as <br /> required in section 2712. <br /> 4 The Airport Way facility was approximately thirteen months late for the annual leak <br /> detector test. Testing was due by May 2005 and was not performed until June 8,2006. <br /> -) The Cherokee Lane facility was approximately five months late for the annual leak <br /> detector test. Testing was due by September 2005 and was not performed until February <br /> 21, 2006. <br /> 4 The Manthey Road facility was approximately one month late for the annual leak <br /> detector test. Testing was due by February 2006 and was not performed until July 12, <br /> 2006. <br /> Title 23, CCR 2638 (d) Annual monitoring certification test report <br /> UST owners and operators shall submit a completed "Monitoring System Certification" form to <br /> the local agency within 30 days after completion of the inspection. <br /> 4 The June 8, 2006, monitoring certification test report for the Airport Way facility has <br /> not been received by this office as of the date of this referral. <br /> 4 The February 27, 2006, monitoring certification test report for the Wilson Way facility <br /> has not been received by this office as of the date of this referral. <br /> Title 23, CCR 2661 Permit to repair UST system. Before repairing an underground storage <br /> tank system, the owner or operator shall demonstrate to the satisfaction of the local agency that <br /> the conditions and requirements specified in subsection 2660(k) will be met. When selecting a <br /> method of repair, the owner or operator shall take into consideration whether the cause of failure <br /> Page 15 of 20 <br />
The URL can be used to link to this page