My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2006 - 2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1100
>
2300 - Underground Storage Tank Program
>
PR0506504
>
COMPLIANCE INFO 2006 - 2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/13/2019 9:44:41 AM
Creation date
5/10/2019 4:24:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006 - 2011
RECORD_ID
PR0506504
PE
2361
FACILITY_ID
FA0007464
FACILITY_NAME
MAIN STREET ARCO AM PM*
STREET_NUMBER
1100
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
APN
22119062
CURRENT_STATUS
01
SITE_LOCATION
1100 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
382
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mar- 28 08 10:03a Sandra Barnhart 2098458586 p.11 <br /> Installer: This instruction booklet MUST be left with the owner of the service station at which the equipment <br /> is being installed. <br /> Station Owner: Retain these instructions for future use and provide trem to oer-scns servicing or removing is <br /> equipment. <br /> STP-MLD Introduction <br /> STP-MLD units are piston-operated mechanical leak detectors intended for installation only in a petroleum pumping <br /> system operating with 20 to 50 PSI pump pressure with less than 12 feet of static fluid head. They automatically <br /> indicate pipeline faults, which leak 3 GPH (gallons per hour)or more at 10 PSI. These leaks are indicated by restricting <br /> system delivery to 3 GPM (gallons per minute) or less at pump pressure of up to 30 PSI in compliance with U,S. EPA <br /> requirements 280.41(b) &280.44(a)for automatic leak detection in pressurized piping. After installation, the user of the <br /> leak detector must monitor system delivery levels to ensure that any restricted delivery of fuel, signaling a leak in the <br /> pipeline, is dealt with promptly. <br /> The STP-MLD units test the delivery pipeline system up to the solenoid valve in the dispenser for leaks whenever <br /> the static system pressure has fallen to one PSI or less, and within 3 to 4 seconds(depending on model)allows full flow <br /> if the system has no leaks. A leak smaller than the required 3 GPH detection level, any air or vapor trapped in the <br /> system, or systems with pressure below 26 PSI,will lengthen the time before the leak detector allows full flow. The leak <br /> detector is not designed to detect leaks from the underground storage tank or the submersible pump. <br /> STP-MLD units are designed for use with FE Petro STP,IST model submersible pumps. STP-MLD units can also <br /> be used in competitive submersible models equipped with a 2" NPT leak detector port or special leak detector tee <br /> housing. The STP-MLD units can be used with gasoline, #2 diesel, kerosene, any combination of gasoline and ethanol <br /> or methanol, up to 20% MTBE and gasoline, up to 20% ETBE and gasoline, or up to 17%TAME andgasoline. STP- <br /> IVILD-D units are for use with diesel fuel and kerosene only. See Technical Bulletin 002(TB002)for specifics on <br /> STP-MLD, STP-MLD-D,and STP-MLD-E models. <br /> The STP-MLD units mount in a 2" NPT threaded leak detector port provided in most submersible petroleum pump <br /> manifolds or a special adapter tee housing and may be installed in any position. The piston chamber of the leak <br /> detector must be vented to the tank. If your submersible pump does not have a "tank" port, the pump will have to be <br /> replaced, a threaded riser must be used, or a different leak detector must be used. <br /> All mechanical leak detectors must be tested upon startup, and routinely thereafter(at least annually) under NFPA <br /> standards. These NFPA and other industry testing practices must be followed by the installer and the end user, <br /> A leak detector is not a substitute for compliance with prudent industry practices. Fuel inventory reconciliation <br /> checks must be performed on a daily basis by comparing dispenser meter totalizers with fuel volume changes in the <br /> underground tank. <br /> Installation Instructions <br /> Installation of two or more STP-MLD's in parallel into the same product piping system will <br /> Caution !\ <br /> result in the smallest leak that is detectable being greater than the EPA requirements. Each <br /> STP-MLD will detect a leak of 3gph or greater. If two STP-MLDs are In parallel, a leak of 6 gph <br /> will be the smallest leak that will be capable of being detected. If three STP-MLDs are in <br /> parallel,a leak of 9 gph will be the smallest leak that is capable of being detected,and so on. <br /> Caution t Third party tests have approved the use of: <br /> STP-MLD in pipelines up to 129 gallon capacity with a bulk modulus between 15,000—35,000 psi/ml. <br /> STP-MLD-D in pipelines up to 370 gallon capacity with a bulk modulus between 16,000—36,ODD psilml. <br /> STP-MLD-E in pipelines up to 49 gallon capacity with a bulk modulus of 1,280 PSI/mi. <br /> Note: A precision line test must be conducted before installing a leak detector for the first time. A precision line test is <br /> also recommended before replacing a leak detector that is having slow flow(tripping) problems to assure line <br /> integrity. <br /> Note: I Before installing the leak detector, purge the system of any air by running the pump and delivering gasoline <br /> from each dispenser(starting with the dispenser farthest from the pump), until all air is removed. The leak <br /> detector will not work properly until all of the air is out of the system. <br /> 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.