My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2006 - 2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1100
>
2300 - Underground Storage Tank Program
>
PR0506504
>
COMPLIANCE INFO 2006 - 2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/13/2019 9:44:41 AM
Creation date
5/10/2019 4:24:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006 - 2011
RECORD_ID
PR0506504
PE
2361
FACILITY_ID
FA0007464
FACILITY_NAME
MAIN STREET ARCO AM PM*
STREET_NUMBER
1100
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
APN
22119062
CURRENT_STATUS
01
SITE_LOCATION
1100 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
382
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mar 28 08 10:04a Sandra Barnhart 2098458586 p,12 <br /> Required Tools <br /> • Standard flat head screw driver, for manual pressure relief. <br /> • 1 pipe wrench (24" minimum)or a 1-'/z"socket for tightening the STP-MLD into the manifold housing. <br /> • 9116"and a 112"open end wrench or an adjustable wrench for attaching flexible tubing fittings. <br /> • UL-classified non-hardening, non-toxic pipe thread sealant. <br /> Preparation <br /> 1. Disconnect power to the submersible pump at the electrical supply box(if already installed). <br /> 2. Tag and lock out electrical circuit breakers so they are not turned on accidentally. <br /> If the electrical circuit breakers are accidentally turned on while installing a leak detector, there <br /> Warning A is the possibility of ignition of hydrocarbon vapors, and/or the installer being bathed in <br /> gasoline, which could result in serious personal injury or death. ALWAYS tag and lock out <br /> breakers so they are not turned on accidentally. <br /> Before commencing the installation of a leak detector, use safety cones, barricades,trucks, etc, <br /> Warning A to isolate the work area. <br /> Relieve line pressure by using the manual pressure relief (if present), or by loosening a pipe <br /> Caution 0 plug either in the manifold cover of the STPIIST or in the shear valve under a dispenser. Make <br /> adequate provision to trap the liquid that escapes to prevent contamination of the environment. <br /> Re-tighten the pipe plug or manual pressure relief. <br /> 3. Remove the two-inch pipe plug or old leak detector from the submersible pump or the adapter tee. <br /> 4_ Examine the straight bore below the two-inch threads for roughness caused by corrosion. If rough, smooth with <br /> fine emery paper. <br /> 5. Apply UL-classified non-hardening, non-toxic pipe thread sealant to the two-inch threads on the leak detector,and <br /> lubricate the O-ring with grease or oil. Make sure the manifold cavity and STP-MLD threads are dry, clean and free <br /> from any debris. If wet,thread sealant may wash off of the applied areas and weeping may result. <br /> 6_ Screw the leak detector into the pump or adapter tee, and tighten with a 1'/" socket or pipe wrench on its hex top. <br /> The STP-MLD must be properly torqued into the manifold to provide a good seal (minimum of 138 foot-pounds) <br /> (see Figure 2), <br /> 7. Remove the plastic dust cover from the vent port at the top of the leak detector. <br /> 8. Remove the 1/4-inch plug from the TANK PORT on the pump. Apply UL-classified, non-hardening, non-toxic pipe <br /> thread sealant to the threads on the tubing fitting and install one 9011 fitting in the leak detector vent port and either <br /> a 900 or straight fitting in the tank port. <br /> Take steps to prevent any foreign materiats from getting into the top of the leak detector as <br /> Caution Q damage to the sealing surfaces in the piston area could result, preventing the leak detector from <br /> operating correctly. <br /> The FE Petro STP/IST's have two labeled ports,one for the syphon system and one for the tank. <br /> Caution 0 The leak detector must be vented to the tank port only. This is the port closest to the tank. Do <br /> not connect a leak detector to the syphon port, as this will make the leak detector inoperative, <br /> causing it to be incapable of detecting a leak, with resulting risk of contamination of the <br /> environment(see Figure 2). <br /> 9. Install the copper tube packed with the STP-MLD into the compression fittings just installed in step 8 above, and <br /> tighten firmly. The tubing may be shortened_ <br /> This line vents the air displaced by piston travel, and drains any liquid,which may leak past the <br /> Caution Q piston seal. When installing this tubing make sure it is not crimped and that it will drain <br /> properly to the tank,or the leak detector will not open properly and could give a false indication <br /> of a leak. Failure to install and connect this tubing could result in environmental contamination. <br /> 10_ Tum power on at the load center and turn on the submerged pump at a dispenser. Look for leaks at the parts just <br /> worked on. If there are any leaks, immediately turn off the pourer at the load center, tag and lock out the breaker, <br /> and repair the leaks. <br /> 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.