Laserfiche WebLink
L <br /> ARCHITECTURE • ENGINEERING, , EN' V' rI_TR Ol/lNCM EN <br /> TAL SERV ICE S <br /> GRoux OT <br /> INC. 1340 Arnold Drive, Suite 110, Martinez, CA94553 Thele 12AA -tULq <br /> Ccrimilr: (923) 313-9709 <br /> 03 OCT 17 PM I: 26 <br /> John W Johnson <br /> Co-President <br /> Architect <br /> October 16, 2003 <br /> Brian E Zita <br /> Co-President Ms.Michelle Le <br /> Architect San Joaquin County <br /> Environmental Health Department <br /> 304 East Weber Avenue,Third Floor <br /> John B. Hicks Stockton,CA 95202 <br /> Vice President <br /> Cecil R. Spencer RE: Safeway Fueling Center#2707 <br /> Vice President 6425 N.Pacific Avenue <br /> Stockton, California <br /> Plan Check#1 Response <br /> Regional Managers <br /> Jesse E. Macias Dear Ms. Le: <br /> Roy W.Pedro This letter is in response to your plan check review comments#1, dated September 29, 2003 <br /> Alan IC Shimabukuro for the Safeway kiosk/Gas Station submitted for application to install underground storage <br /> John W Strobel tanks at the above referenced location. Our responses to the review comments are listed <br /> Blythe R.Wilson below and attempt to follow the same order of appearance as your review documents. <br /> 1, A balance in the amount of$135.00 dollars is due. The fee received by this office paid <br /> for the installation of 2 underground storage tanks but 1 tank is split into 2 <br /> compartments therefore,3 UST's are being proposed. <br /> A check in the amount of$135.00 is attached. <br /> 2. Buoyancy calculations signed by a professional engineer or licensed architect must be <br /> submitted. <br /> Two(2) copies of the tank buoyancy calculations signed by a licensed engineer <br /> are attached. <br /> 3. Page FS3-drawing 4 shows a connector tube being used to link the piping through the <br /> dispenser pans. Secondary termination must occur within the dispenser pan. Clarify <br /> Offices drawing. <br /> BELLEVUE, WA The connector tube is located inside the dispenser sump. Any product leakage <br /> LA HABRA, CA within the tube will be secondarily contained within the dispenser sump. <br /> MARTINEZ, CA <br /> 4. The permit application specifies that overfill prevention will be satisfied using CCR <br /> PETALUMA, CA 2365(b)(2)(B). However,manufactures specification sheets were not submitted for an <br /> SACRAMENTO, CA external audible/visual alarm and the location of this alarm was not implicated on the <br /> drawings. <br /> SCOTTSDALE, AZ <br /> VANCOUVER, WA <br /> wwuxrhldesign.cons <br />