My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL 2003
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6425
>
2300 - Underground Storage Tank Program
>
PR0231211
>
INSTALL 2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/22/2019 11:34:29 AM
Creation date
5/15/2019 11:02:20 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2003
RECORD_ID
PR0231211
PE
2371
FACILITY_ID
FA0002409
FACILITY_NAME
SAFEWAY FUEL CENTER #2707
STREET_NUMBER
6425
Direction
N
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
CURRENT_STATUS
01
SITE_LOCATION
6425 N PACIFIC AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
299
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project No. JB -314 <br />24 March 2003 <br />Page 8 <br />of the proposed structures, supported as recommended, should be less than 1 <br />inch. Recommendations for footing depths and foundation details are included in <br />Table 3. <br />The excavations for footings must be cleaned of all loose materials and debris, <br />and moistened prior to placement of concrete. All footing excavations must be <br />observed by our representative to verify the condition of the bearing material. If <br />any localized areas of loose or soft undesirable subsoil are observed in footing <br />excavations, the excavation for the footings must be over -excavated to firm soil <br />and backfilled with compacted fill under the observations and testing of our <br />representative. <br />All footings should be reinforced with top and bottom reinforcement to provide <br />structural continuity and to permit spanning of local irregularities. The <br />reinforcement of the footing should be designed by a structural engineer. <br />If a different type of foundation system is desired, this office should be called for <br />supplemental recommendations. Such recommendations will be presented as an <br />addendum to this report. <br />Table 3 <br />FOUNDATION DESIGN CRITERIA <br />CONTINUOUS STRIP AND ISOLATED FOOTINGS <br />Width: <br />Wall Footings (Continuous) <br />Column Footings (Isolated) <br />Embedment Depth' <br />Compacted Fill <br />Allowable Bearing Capacity' <br />Compacted, Engineered Fill <br />Coefficient of Sliding Friction <br />Criteria <br />Minimum 12 inches <br />Minimum 24 inches <br />Minimum 18 inches <br />2,000 psf <br />0.30 <br />1. Footing embedment depth is measured from the lowest adjacent soil grade to the <br />bottom of the footing. <br />2. The recommendations above are for a foundation designed for net dead plus live <br />loads. These bearing pressures may be increased by one-third for wind or seismic <br />loads. <br />hi!IiKorb,macher Engineering, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.