LARCHITECTURE • ENGINEERING • ENVIRONMENTAL S ERV I C E S <br /> GROUP INC. 1340 Arnold Drive, Suite 110, Martinez, CA 94553 Telephone: (925) 313-9700 Facsimile: (925) 313-9709 <br /> February 24, 2004 RECENED <br /> John W.Johnson <br /> Co-President Ms. Michelle Le FEB 2 5 2004 <br /> Architect San Joaquin County-Environmental Health Department <br /> 304 East Weber Avenue,Third Floor ENVIRONMENT HEALTH <br /> PERMIT/SERVICES <br /> Brian E Zita Stockton, CA 95202 RVICES <br /> Co-President <br /> Architect RE: Safeway Fueling Center#2707 <br /> 6425 N.Pacific Avenue <br /> Stockton, California <br /> John B. Hicks Equipment changes/additions (for"test site"application) <br /> Vice President <br /> Dear Ms. Le: <br /> Cecil R.Spencer As you are aware, Safeway is constructing this fuel facility as a test site. That is to say they are <br /> Vice President installing components/systems,but not activating them, to accommodate either the hydrostatic or <br /> vacuum monitoring system for the secondary containment that may be approved by the SWRCB on <br /> Regional Managers or before July 1st <br /> Jesse E. Macias This submittal addresses the changes and additions to the previously approved/permitted equipment <br /> Roy W. Pedro as you requested at our site meeting on February 18,2004. Enclosed for your review and approval <br /> Alan K. Shimabukuro are the following: <br /> John W. Strobel <br /> • 3-sets of revised plans(including electrical site plan ES 1 &monitoring Sys. diagram E4). <br /> Blythe R Wilson 2 conies of the following: <br /> • Approval letter from Modern Welding for 7' UST burial depth. <br /> • Third party approval letter and drawings for Western Fiberglass double wall tank,under <br /> dispenser and transition sumps(refer to previously submitted W.F. UST,UDC and transition <br /> sump cut-sheets for material specifications). <br /> • Blueline Technologies Letter,UL report for sump entry fittings,product bulletins/MSDS for 801 <br /> bonder,4036 sealant and the NTS test report, and cut-sheets/product test data for nylon <br /> "Flexiclamp"and(1) sample clamp. <br /> • Wilcox evaluation/report for Western Fiberglass liquid filled Co-Flow piping system. <br /> • Wilcox evaluation/report for Ameron Dualoy brine filled piping system. <br /> • UL letter stating that Ameron fiberglass piping is not affected by the calcium chloride brine <br /> solution. <br /> Your expeditious review and approval of the additions and changes will be greatly appreciated as the <br /> site is presently under construction. Please do not hesitate to call me if you have any questions and <br /> feel free to contact Safeway's petroleum equipment supplier, Gene Rotter of Shields Harper&Co. at <br /> Offices (707) 987-2780, if you have questions regarding product specifications, approvals, cut-sheets,etc. <br /> ANAHEIM, CA Respectfully, <br /> BELLEVUE, WA RHL DESIGN GROUP,INC. <br /> CAMAS, WA <br /> MARTINEZ, CA <ZaGiaeo <br /> Project Manager <br /> PETALUMA, CA <br /> cc: Safeway <br /> ROSEVILLE, CA file <br /> SCOTTSDALE, AZ enclosures <br /> www.rhldesign.com <br />