• San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.or /g ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Safeway Fuel Center #2707 <br />FacilityAddress: <br />6425N PACIFIC AVE STOCKTON <br />Dater <br />January 19, 2017 <br />On Site Records <br />204 <br />CCR 2712(1) <br />Current monitoring plan approved by the END not found on site <br />a V ❑ R o COS <br />205 <br />CCR 2712(1) <br />Failure to have an approved UST response plan available onsite <br />o V o -R1 COS <br />206 <br />CCR 2712 <br />Failure to comply with UST operating permit conditions <br />o V o R a COS <br />207 <br />HSC 25294 <br />Failed to record unauthorized release from primary containment <br />❑ V a R ❑ COS <br />208 <br />CCR 2650(e) <br />Failed to notify the END of a reportable unauthorized release <br />o V ❑ R o COS <br />209 <br />CCR 2715(c) <br />Designated operator did not Inspect all required items and/or the inspection reports not completed <br />❑ V a R a COS <br />210 <br />CCR 2715(9) <br />Designated operator monthly Inspection reports not maintained on site for at least 12 months <br />o V o R ❑ COS <br />211 <br />CCR 2715M <br />Designated operator employee training not performed or log not kept <br />n V o R o COS <br />212 <br />CCR 2716(f)(2) <br />Unstaffed facility failed to have or Implement a training program approved by the END <br />❑ V o R o COS <br />213 <br />HSC 25281.5(6)(2) <br />Unburied fuel piping at marinas not visually Inspected at least daily or log not kept <br />o V ❑ R a COS <br />214 <br />HSC 25281.5(b)(3) <br />Unburied emergency generator fuel piping not visually inspected at least monthly or log kept <br />o V u R o COS <br />USTSystem Observations <br />301 <br />HSC 25292.1 <br />UST system is not operated to prevent unauthorized release, including spills and overfills <br />n V n R o COS <br />302 <br />HSC 25291(b) <br />UST system incapable of detecting leak from primary Into secondary containment (pre-Jul 2003) <br />o V a R a COS <br />303 <br />HSC 25290.2(d) <br />Monitoring system not maintained to detect entry into secondary containment (Jul 2003-Jun 2004) <br />o V a R ❑ COS <br />304 <br />HSC 26290.1(d) <br />Monitoring system not maintained to detect entry Into secondary containment (after Jul 2004) <br />o V a R ❑ COS <br />306 <br />HSC 25290.1(9) <br />VPH monitoring of the interstitial spaces of the UST system Is not maintained <br />a V ❑ R a COS <br />306 <br />CCR 2630(4) <br />Monitoring equipment ie not installed or maintained to detect a leek at the earliest opportunity <br />■ V ■ R o COS <br />307 <br />CCR 2632(c) <br />Monitoring system of the Interstitial space of a double walled system not maintained <br />a V a R ❑ COS <br />308 <br />CCR 2036(f) <br />Failed to maintain a continuous monitoring system that activates an audible and visual alarm <br />o V a R o COS <br />309 <br />CCR 2636(f)(1) <br />Monitoring In sump / UDC failed to activate an audible and visual alarm or stop the flow product <br />n V o R o COS <br />310 <br />CCR 2636(})(5) <br />Piping Is not fail-safe outside UDCs or falls to stop flow of product at dispenser Inside UDCs <br />o V a R a COS <br />311 <br />CCR 2638(a), 2641 0) <br />Failed to properly program or operate leak detection equipment <br />o V c R o COS <br />312 <br />CCR 26380 <br />Failed to affix a tag sticker on monitoring equipment caRHled, repaired, or replaced <br />a V a R o COS <br />313 <br />HSC 25290.1, 25290.2, <br />25291 <br />Failure to construct, operate, and maintain primary containment as product-tight <br />o V o R a COS <br />314 <br />HSC 25290.1, 25290.2, <br />26291 <br />Failed to have secondary containment or secondary containment not tight <br />n V o R ❑ COS <br />315 <br />HSC 25201 (8) <br />Water In secondary containment not removed, analyzed, and properly disposed of (pre-Jul 2003) <br />. V . R e COS <br />316 <br />HSC 25290.1(03), <br />25290.2(c3) <br />Secondary containment not constructed to prevent water Intrusion (after Jul 2003) <br />o V c R o COS <br />317 <br />CCR 2636(f)(2) <br />Line leak detector not Installed <br />o V a R a COS <br />318 <br />CCR 2636(f)(2) <br />Leak detector failed to detect a 3.0 gph leak at 10 psi <br />o V o R ❑ COS <br />319 <br />CCR 2695(b) <br />No spill bucket, faded to contain five gallons, or faded to provide a means to keep It empty <br />■ V a R o COS <br />320 <br />CCR 2635(b)(2) I <br />Overfill prevention system not present or failed to meet overfill requirements <br />o V a R ❑ COS <br />321 <br />CCR 2636(b)(2) <br />Overfill prevention was overridden <br />o V ❑ R a COS <br />EHD 23-01 Rev. 09(22/18 <br />FA0002409 PRO231211 SC001 01/19!2077 <br />Page 2 of 5 Underground Storage Tank Program OIR <br />