Laserfiche WebLink
FA0002409 PRO231211 60001 01/19@017 <br />EHD 2301 Rev. 09112116 Page 3 of 5 Underground storage Tank Program OIR <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.siaov.oro/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Safeway Fuel Center #2707 <br />Facility Address: <br />6425 N PACIFIC AVE, STOCKTON <br />Date: <br />January 19, 2017 <br />., <br />UST System 4lbee atlows, <br />322 <br />HSC 25281.6(n) <br />Unburied below grade emergency generator system failed to meet exemption status ❑ V ❑ R <br />a COS <br />323 <br />HSC 25283.5(x) <br />Unburied below grade UST system failed to meet exemption status ❑ V ❑ R <br />❑ COS <br />324 <br />CCR 2717.1(9) <br />Tampered with red tag a v o R <br />❑ COS <br />325 <br />CCR 2717.1(f) <br />Deposited petroleum Into a red tagged UST ❑ V o R <br />a CAS <br />326 <br />HSC 25299(a)(9) <br />Tampered with or disabled leak detection devices or alarms ❑ V a R <br />o COS <br />327 <br />CCR 2631.1 <br />UST system not compatible with the substance stored o V a R <br />n COS <br />328 <br />HSC 25298 <br />Failed to comply with temporary closure requirements n V o R <br />o COS <br />329 <br />HSC 25298 <br />Failed to comply with permanent closure requirements ❑ V ❑ R <br />❑ COS <br />330 <br />CCR 2636(f)(6) <br />Failure to meet all requirements in lleu of a line leak detector for emergency generator tank system a V o R <br />❑ COS <br />Single -Wailed Non -Pressurized Piping <br />401 <br />CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve ❑ V a R <br />a COS <br />402 <br />CCR 2643(d) <br />Dally monitoring of suction pipe (pre -Jan 1984) not performed o V o R <br />e COS <br />403 <br />CCR 2643(d) <br />Triennial 0.1 gph line lest for conventional suchen piping not performed (pre -January 1984) o V o R <br />a COS <br />404 <br />CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) o V n R <br />❑ COS <br />Other Violations <br />2010 <br />Sea below <br />Unlisted Administration/Documentation violation o V ❑ R <br />❑ COS <br />2030 <br />See below <br />Unlisted Operattons/Maintenance violation a V o R <br />❑ COS <br />2060 <br />See below <br />Unlisted Design(Constructlon violation e V o R <br />o COS <br />SUMMARY OF VIOLATIONS <br />„(CLASS 1, CLASS Il, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />105 <br />CCR 2632(d)(1) Failed to have an approved UST monitoring plan. <br />The monitoring plan is not current and/or not approved by the EHD. For all three underground storage tanks, <br />beneath Record Keeping, change "Yes" to "No' for Tank Integrity Testing Results.. The monitoring plan must be <br />uploaded to the California Environmental Reporting System (CERS). Immediately log into CERS, make the <br />necessary changes, and submit for review by the EHD. <br />This is a minor violation <br />107 <br />CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring Is performed. <br />An accurate UST Monitoring Site Plan was not submitted. A site plan must be submitted identifying the locations <br />where monitoring will be performed. The Site Plan does not indicate that there is a sensor in the submersible turbine <br />pump sump for 91 -product, and the fill sumps for 91-poduct and diesel product and that there is a sensor in the vent <br />sump. Also the leak detector locations are not included in the Plot Plan. Immediately log into the California <br />Environmental Reporting System (CERS) at httpi/mrs.colepa.ca.gov/ and upload a copy of the UST Monitoring Site <br />Plan. <br />This is a minor violation. <br />FA0002409 PRO231211 60001 01/19@017 <br />EHD 2301 Rev. 09112116 Page 3 of 5 Underground storage Tank Program OIR <br />