10. FILL RISER CONTAINMENT SUMP TESTING <br />Facility is Not Equipped With Fill Riser Containment Sumps ❑ <br />Fill Riser Containment Sumps are Present, but were Not Tested ❑ <br />Test Method Developed By: ❑ Sump Manufacturer ® Industry Standard ❑ pro �cssianefVtwe7ft <br />❑ Other (Specifp) <br />Test Method Used: ❑ Pressure ❑ Vacuum ® Hydrostatic <br />❑ Other (Speoh ) <br />Test Equipment Used: Incon Sump Tester Equipment Resolution: -- 0.002" <br />Fill Sump 9 87 <br />Fill Sump 4 91 <br />Fill Sump tl Diesel <br />Vent Sump <br />Sump Diameter: <br />42" <br />42" <br />42" <br />18" <br />Sump Depth: <br />83" <br />81" <br />81" <br />31" <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />36„ <br />34' <br />36" <br />8" <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />34" <br />36" <br />34" <br />10" <br />Condition of sump prior to <br />testing: <br />Good <br />Good <br />Good <br />Good <br />Portion of Sump Tested <br />T' above pipm <br />2" above piping <br />2" above piping <br />above piping <br />Sump Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />30 minutes <br />30 minutes <br />30 minutes <br />30 minutes <br />Test Start Time: <br />11:21 am <br />11:21 am <br />11:21 am <br />12:00 pm <br />Initial Reading (R,): <br />4.0993 <br />5.3700 <br />5.3350 <br />1.2891 <br />Test End Time: <br />11:36 am <br />11:36 am <br />11:36 am <br />12:15 pm <br />Final Reading (RF): <br />4.0990 <br />5.3697 <br />5.3351 <br />1.2886 <br />Test Duration: <br />15 min. <br />15 min. <br />15 min. <br />15 min. <br />Chane in Reading (RF -R,): <br />0.0003 <br />0.0003 <br />0.0001 <br />0.0005 <br />Pass/Fail Threshold or Criteria: <br />+/-0.002" <br />+/- 0.002" <br />+/-0.002" <br />+/-0.002" <br />Test Result: <br />® Pass 0 Fail <br />© Pass 0 Fail <br />© Pass 0 Fail <br />© Pass 0 Fail <br />Is there a sensor in the sump? <br />® Yes ❑ No <br />® Yes ❑ No <br />® Yes ❑ No <br />® Yes ❑ No <br />Does the sensor alarm when <br />either product or water is <br />detected? <br />❑ Yes ❑ No ®NA <br />❑ Yes ❑ No ®NA <br />❑ Yes ❑ No ®NA <br />❑ Yes ❑ No ®NA <br />Was sensor removed for testing? <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />CKYes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testin ? <br />®yes ❑ No ❑ NA <br />®Yes ❑ No ❑ NA <br />®Yes ❑ No ❑ NA <br />®Yes ❑ No ❑ NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-upjor (ailed tests) <br />Sensor functionality was not confirmed. This procedure is not part of I.he Secondary Containment testing scnpe of work <br />