Laserfiche WebLink
Tracy Toyota Waste Anti -Freeze Tank Assessment <br />Written Assessment per CCR Title 22 , 66265.192, 66265.193 <br />Integrity Assessment <br />Leak Test: The secondary containment was inspected and found to be dry. <br />Inspection of visible piping joints and flanges found to be dry. UTG thickness <br />measurements follow. <br />Tracy Honda Waste Antifreeze Tank <br />Hydrostatic Calculation <br />Tank wall thickness, in <br />Tank Dia. In. <br />Depth of fluid in tank, ft <br />S.G. of Fluid <br />Pressure of fluid at bottom of tank, psi <br />hoop stress at bottom of shell, psi <br />Yield Stress LPE , psi <br />joint effeciency <br />effective allowable stress, psi <br />Safety Factor <br />Tank is okay for hydrostatic <br />Tank Buckling <br />F, lbs <br />moment arm, in <br />M, inlbs <br />y max, in <br />I, in4 <br />Buckling Stess, psi <br />Maximum Stress,LPE <br />Safety Factor <br />Tank is okay for buckling <br />Figure 6, Waste Antifreeze <br />0.33 <br />36.00 <br />3.68 <br />1.05 <br />1.67 <br />4WAI <br />2000.00 <br />1.00 <br />1154.00 <br />12.65 <br />515.60 <br />22.05 <br />11368.98 <br />18.00 <br />5878.95 <br />34.81 <br />1154.00 <br />33.15 <br />Tank Hydrostatic Calculation <br />Strandberg Associates 1(866) 388-0404 (650) 329-3918 rwater uy(M-rwaterquv.com 7 <br />