My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHRISTOPHER
>
18551
>
2900 - Site Mitigation Program
>
PR0540588
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2019 10:20:26 AM
Creation date
5/30/2019 9:49:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
WORK PLANS
RECORD_ID
PR0540588
PE
2965
FACILITY_ID
FA0023216
FACILITY_NAME
CITY OF LATHROP CROSSROADS WASTEWATER TREATMENT FACILITY
STREET_NUMBER
18551
STREET_NAME
CHRISTOPHER
STREET_TYPE
WAY
City
LATHROP
Zip
95330
APN
19813033
CURRENT_STATUS
01
SITE_LOCATION
18551 CHRISTOPHER WAY
P_LOCATION
07
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
September 30, 2015 Monitoring Well Abandonment and <br /> Installation Workplan <br /> Table I <br /> Construction Information for Monitoring Wells to be Abandoned. <br /> Diameter Depth screened <br /> Well ID Year Drilled Interval Proposed Action <br /> (inches) (feet bls) <br /> (feet bls) <br /> KMW-1 2001 4 30 8-30 Destroy <br /> KMW-3 2001 4 30 10-30 Destroy <br /> 1.5. Proposed Replacement Monitoring Well Installation <br /> Replacement monitoring wells may be required to monitor the effectiveness of the Salinity <br /> Mitigation Plan. Second Quarter 2015 water levels in the WWTF and CTF monitoring wells <br /> and groundwater elevation contours are shown on Figure 2.7 If required,the abandoned <br /> wells shall be replaced by installing one new monitoring well(KMW-10)along the western <br /> edge of LAS-2 and one new monitoring well (KMW-11) along the northern edge of LAS-1 <br /> (Figure 3). The KMW-3 replacement(KMW-10) location was chosen due to its <br /> downgradient location from KMW-3 and future sampling access at the edge of LAS-2.The <br /> KMW-1 replacement(KMW-11) location was chosen due to its close location td KMW-land <br /> future sampling access at the edge of LAS-1. <br /> Table 2 summarizes current and proposed functions of the wells in the WWTF monitoring <br /> network. <br /> TableCurrent and ... <br /> Well ID Current Function Proposed Function <br /> KMW-1 LAS-1 compliance To be destroyed <br /> KMW-2 LAS-2&-3 compliance Continued monitoring at LAS-2&-3 <br /> KMW-3 LAS-2 compliance To be destroyed <br /> KMW-4 LAS-3 compliance Percolation pond compliance <br /> KMW-6 Background Percolation pond compliance <br /> KMW-8 Percolation pond compliance Percolation pond compliance <br /> KMW-9 Percolation pond compliance Percolation pond compliance <br /> KMW-10 To be installed Monitoring at LAS-2 <br /> KMW-11 To be installed Monitoring at LAS-1 <br /> MW-5 Pond A, B, C compliance Pond A, B, C compliance <br /> W-1 Pond A, B,C compliance Pond A, B, C compliance <br /> W-2 Pond A, B, C compliance Pond A, B, C compliance <br /> Table 3 summarizes construction information for the proposed new replacement wells that <br /> will be used to monitor LAS-1 and LAS-2,if required. KMW-10 and KMW-11 shall be <br /> installed with provided protection for any site construction activities. <br /> 7 Hydro Focus, Inc.City of Lathrop Second Quarter 2015 Groundwater Monitoring Report,Crossroads <br /> Wastewater Treatment Facility Order No.5-01-251.July 31,2015. <br /> HydroFocus, Inc. 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.