My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHRISTOPHER
>
18551
>
2900 - Site Mitigation Program
>
PR0540588
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2019 10:20:26 AM
Creation date
5/30/2019 9:49:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
WORK PLANS
RECORD_ID
PR0540588
PE
2965
FACILITY_ID
FA0023216
FACILITY_NAME
CITY OF LATHROP CROSSROADS WASTEWATER TREATMENT FACILITY
STREET_NUMBER
18551
STREET_NAME
CHRISTOPHER
STREET_TYPE
WAY
City
LATHROP
Zip
95330
APN
19813033
CURRENT_STATUS
01
SITE_LOCATION
18551 CHRISTOPHER WAY
P_LOCATION
07
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
5 <br /> January 25, 2016 AUG 2 2016 Monitoring We I Abandonment Workplan <br /> C-° <br /> • The wells located withinl(OF,SP an&River Islands (CLSP-2,CLSP-4,CLSP 10,MWR-6,MWR-13, <br /> MWR-15,and MWR-20)should be abandoned by over-drilling to remove all the material within <br /> the original borehole including the well casing,screen,filter pack and annular seal per San <br /> Joaquin County well standards.This is necessary when well construction is unknown, or when <br /> obstructions are found in the well. The material extracted from the original borehole should be <br /> removed under direction of a SJCEHD inspector,and the excavated well boring should be filled <br /> with sealing materials by free-fall at depths shallower than 30 feet or t emie pipe or equivalent <br /> at deeper depths,proceeding upward from the bottom of the well orb ring.Sealing materials <br /> should be placed in one continuous operation,and the pressure required for the placement of <br /> sealing material should be maintained long enough for sealing materia s to properly set.After <br /> the sealing operation is completed and the sealing material has set,the remaining excavation <br /> should be filled with clean soil. <br /> Per the San Joaquin County well standards,if well construction is kno n and the well was <br /> installed and maintained according to the County well standards,the well can be abandoned by <br /> pressure-grouting.Therefore,the wells located within Mossdale (MW -14,MWM-16,and <br /> MWM-26) should be abandoned by pressure-grouting.Pressure for grout emplacement should <br /> be maintained long enough for the grout to properly set.The well casing should be left in place <br /> during sealing operations.A hole at least one foot larger in diameter than the originally drilled <br /> hole should be excavated around the outside of the well casing to a de th of three feet below <br /> the ground surface,and the well casing should then be cut off six inches above the bottom of <br /> this excavation and removed.The grout used to fill the well should beallowed to spill over into <br /> the excavation during the sealing operation,and fill the excavation up to a thickness of one foot <br /> forming a"cap"which has a diameter of at least one foot greater than the diameter of the <br /> originally drilled hole.After the sealing operation is completed and thE sealing material has set, <br /> the remaining excavation should be filled with clean soil to just below street grade.The surface <br /> should be re-paved to match the surrounding street grade using either black stained concrete <br /> or hot asphalt.The surface completion should be approved by the City of Lathrop Public Works <br /> department. <br /> • Sealing material will be selected based on the required structural,han fling,and sealing <br /> properties,and the chemical environment into which it is placed.Sea1i ng materials should have <br /> such low permeability that the volume of water passing through them is of little consequence. <br /> Suitable materials can include neat cement and sand-cement grout. Us ed drilling mud or <br /> cuttings from drilling should not be used for any part of the sealing m terial.For abandonment <br /> of these wells,neat cement should be used. Potable water should be used for sealing mixtures. <br /> 3. Schedule for Completion of Work and Reporting <br /> Submission of this Monitoring Well Abandonment Workplan is required pr or to the scheduled <br /> construction or abandonment of any groundwater monitoring well. For w Als currently located in <br /> the City right-of-way or on City owned property,abandonment will occur y November 30,2016. <br /> For wells that are on private property,the City will work with land owner to explain the well <br /> abandonment procedure and develop a plan to complete work.Abandonn ient of wells located on <br /> HydroFocus, Inc. 5 <br />