Site Background Information: West Clay Properties <br /> Page 4 of 10 <br /> the former UST No. 3 location to determine the down-gradient extent of petroleum <br /> hydrocarbon-impacted ground water. CPT-03 was advanced to approximately 210 feet bsg <br /> -CPT-03 was sampled between 50 and 54 feet bsg, 74 and 78 feet bsg, 133 and 137 feet bsg <br /> and 176 and 180 feet bsg; <br /> • CPT-04 and associated ground water sampling borings were advanced north of the former <br /> UST cluster excavation (Figures 2 and 4) to determine the vertical extent of petroleum <br /> hydrocarbon-impacted ground water at the former UST cluster area. CPT-0�was advanced �— <br /> to approximately 175 feet bsg. [� <br /> • Ground water sampling boring CHB-01 was advanced approximately 70 feet east-northeast <br /> of CPT-04 to determine the vertical extent of petroleum hydrocarbon-impacted ground water <br /> down-gradient of the former UST cluster area-CPT-04 was sampled between 80 and 84 feet <br /> bsg and 166 and 170 feet bsg;while - soil boring CHB-01 was sampled between 78 and 82 <br /> feet bsg. <br /> ANALYTICAL RESULTS OF GROUND WATER SAMPLES <br /> Various concentrations of target analytes were detected in each grab ground water sample collected <br /> from each sampling interval in soil borings advanced near the former UST No. 3 location(CPT-01 <br /> through CPT-03). Analytes of concern were not detected above laboratory reporting limits in grab <br /> ground water samples collected from soil borings advanced near the former UST cluster area(CPT- <br /> 04 and CHB-01). <br /> Former UST No. 3 Location <br /> Analytical results of CPT ground water sampling at the former UST No. 3 area are as follows: <br /> • HU-2: TPH-g and TPH-d were detected in the ground water sample collected from HU-2 at <br /> a concentration of 27,000 micrograms per liter(gg/l)and 8,800µg/1,respectively,in sample <br /> CPT03/50-54. BTEX constituents were detected in the same sample at concentrations of 21 <br /> µg/1 (benzene), 1,000 gg/l (toluene), 1,700 gg/l (ethylbenzene) and 6,200 gg/l (total <br /> xylenes). <br /> • HU-3: TPH-g was detected in ground water samples collected from HU-3 at concentration <br /> ranging from 110 gg/l to 190 gg/l in samples CPT03/74-78 and CPTO1/77-81,respectively. <br /> BTEX constituents were detected at concentrations as high as 12 gg/l benzene <br /> (CPTO1/77-81), 27 gg/l toluene (CPTO1/77-81), 8.6 gg/l ethylbenzene (CPT03/74-78) and <br /> 38 gg/1 total xylenes (CPT03/74-78). TPH-d was not detected in the ground water samples <br /> collected from HU-3. <br /> • HU-4: TPH-g and TPH-d were detected in ground water samples collected from HU-4 at <br /> concentrations as high as 30,000 gg/l and 25,000 gg/l, respectively in sample <br /> Advanced GeoEnvironmental,Inc. <br />