Laserfiche WebLink
TEST SCHEDULE <br /> 1 Week prior to start test Place pressure transducers in RW I A and RW 1 B and M W 1 <br /> 2 Day one, Step drawdown test RW I A Test will last S to 10 hours Formation allowed to recover <br /> over night <br /> 3 Day two, step drawdown test RW1B Test will last S to 10 hours Formation allowed to recover <br /> overnight <br /> 4 Day three, constant rate test RW 1 A Test will last into day four (24 hours) Formation allowed <br /> to recover for one day <br /> 5 Day Five, constant rate test RW 1 B Test will last into day six (24 hours) Formation allowed to <br /> recover for one day <br /> 6 Day Eight, Well communication tests for MW6A and MW6B and for MW7A and MW7B <br /> Each test will last two hours, with two hours bevveen the tests to allow for formation recovery <br /> 5 <br /> Rev Pump Test Plan- 10/11/02 <br />