Laserfiche WebLink
f3Wy Kwikce, 1/15/95 <br /> extent of contamination to the east of the dispenser island is unknown at the present time. <br /> 6.0 AINM RECOMMENDA7 ;�T3 <br /> The lack of strong evidence of soil contamination in the vicinity of lu-I and IAF-2 indicates that <br /> groundwater in these wells has probably been contaminated by downgradient migration of <br /> hydrocarbon contaminants within the saturated zone. Potential upgradient sources of this <br /> contamination include the two UST's and dispsensers at the site, the leaking UST's that were <br /> formerly present at the neighboring Chevron site, and the suspicious site across the street from <br /> the Chevron site. We recommend continued groundwater monitoring, as well as further <br /> assessment of the extent of contamination to the north and east. The next monitoring event and <br /> the installation of additional wells should be performed during the first quarter of 1395 and <br /> reported in the next Quarterly Report. <br /> 7.©1LIZMA� S AND SSG TATU <br /> The recommendations contained in this report represent a professional opinion, and are based in <br /> part on information supplied by the client. The opinions are based on currently available <br /> information and are arrived at in accordance with currently accepted hydrogeologic and <br /> engineering practices at this time and location. Other than this, no warranty is implied or <br /> intended. <br /> Respectfully Submitted, <br /> Upgradient Environmental Consultants <br /> T <br /> Victor B. Chery <br /> Registered G .� t #34 `x', <br /> V <br /> i <br />